Reading the ledger…
THE INDEX: 64 ▼17 · week of Jun 29 — permits soft, openings quiet, deal ledger quiet
Reading the ledger…
The raw feed behind the newsletter. Free tier: the trailing 90 days, 25 rows a page — enforced at the query, not just the pixels.
Reading the record?Get the week's biggest deals, permits, and the LLCs behind them — one free email every Thursday, every number checkable here.
Index Pro — full history, CSV exports, and morning-of alerts. $39/mo, coming soon. Get notified at launch:
New · The distress rolls
39,333 properties owe the city back taxes — 1,734 flagged for sheriff sale.
| Issued | Address | Type / scope | Units | Contractor | Com. | Zip |
|---|---|---|---|---|---|---|
| Issued Jun 18, 2026 | 2209 TAGGERT ST | AlterationsREPAIR/REPLACE CT & FAI. | — | BEST CHOICE PLUMBING INC.. | 19125 | |
| Issued Jun 18, 2026 | 18 E COLUMBIA AVE | Addition and/or Alterationinstallation of 40 recessed lights, 40 electrical outlets, carbon monoxide and smoke alarms, 240V outlets for water heater, 200 amp electrical service and panel. low voltage for entertainment |
Free tool
Want every new-construction permit mapped to corridors, weekly? Get the free Building Report →
| — |
| Jerry Davis |
| 19125 |
| Issued Jun 18, 2026 | 1313 FRANKFORD AVE | Addition and/or AlterationsINSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 AND 13R THROUGHOUT THE BUILDING TO INCLUDE 2" MAIN FIRE SERVICE LINE WITH A BACKFLOW PREVENTION ASSEMBLY, AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. | — | B M CONSULTING SERVICES INC | C | 19125 |
| Issued Jun 17, 2026 | 1850 E OAKDALE ST | New construction, addition, GFA changeFOR THE ERECTION OF ONE STORY ADDITION ABOVE THE EXISTING SECOND FLOOR AND ERECTION OF ACCESSORY ROOF DECK (FOR RESIDENTIAL USE ONLY) WITH ROOF ACCESS STRUCTURE ALL AS PART OF AN EXISTING ATTACHED STRUCTURE. SIZE AND LOCATION AS SHOWN IN THE APPLICATION / PLAN. | — | SIMON B AGUASVIVAS | 19125 |
| Issued Jun 17, 2026 | 2026 E FIRTH ST | Addition and/or AlterationsEZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 60K BTU furnace, 2.5 ton AC, ductwork, and (10) diffusers | — | ANDRIUS RATKEVICIUS INC | 19125 |
| Issued Jun 17, 2026 | 1569 E HEWSON ST | Addition and/or AlterationWire through single family house, new service 200 amp upgrade, decora devices, switches, receptacles, smokes, 4'' LED recessed lights, and ARCF breakers according to NEC 2017 | — | ANTHONY L DAVIS JR | 19125 |
| Issued Jun 17, 2026 | 1901-19 E YORK ST | Addition and/or AlterationElectrical Permit for combo CP-2026-002672 | — | US ELECTRICAL CONSTRUCTION CO INC | C | 19125 |
| Issued Jun 17, 2026 | 2417 GAUL ST | Addition and/or AlterationAdd 2 switches, Add 2 outlets, Device Replacement Only. | — | JOSEPH WENTWORTH | 19125 |
| Issued Jun 17, 2026 | 1910 E HUNTINGDON ST | Full DemolitionComplete demolition to create vacant lot | — | A2 Design Group LLC | C | 19125 |
| Issued Jun 17, 2026 | 2627 E LEHIGH AVE | New construction, addition, GFA changeFOR THE ERECTION OF A TWO (2)-STORY REAR ADDITION ABOVE AN EXISTING ONE (1)-STORY GARAGE, AND A ONE (1)-STORY ADDITION ABOVE AN EXISTING TWO (2)-STORY STRUCTURE, INCLUDING A ROOF DECK ACCESSED BY A ROOF DECK ACCESS STRUCTURE. FOR USE AS A MIXED-USE BUILDING CONSISTING OF AN EXISTING TAKE-OUT RESTAURANT ON A PORTION OF THE FIRST FLOOR (PREVIOUSLY APPROVED UNDER ZP-2025-006152), AND THE TWO (2) FAMILY DWELLING UNITS, WITH TWO (2) EXISTING ACCESSORY INTERIOR OFF-STREET PARKING SPACES ACCESSED FROM | — | Creative Innovations Group LLC | C | 19125 |
| Issued Jun 16, 2026 | 1415 E OXFORD ST | New ConstructionFOR THE ERECTION OF A FOUR (4) STORY ATTACHED STRUCTURE OF TYPE III-B CONSTRUCTION SLAB ON GRADE, A ROOF DECK AT THE 4TH FLOOR ACCESSED BY THE 4TH FLOOR FRONT, A ROOF DECK AT THE 3RD FLOOR ACCESSED BY THE 3RD FLOOR REAR, A ROOF DECK AT THE 2ND FLOOR ACCESSED BY THE 2ND FLOOR REAR. FOR USE AS A SINGLE-FAMILY DWELLING (GROUP R-3) WITH THREE (3) ACCESSORY OFF STREET SURFACE PARKING SPACES ACCESSED BY A SHARED DRIVE AISLE. BUILDING TO BE FULLY SPRINKLERED WITH A MINIMUM OF AN NFPA 13R AUTOMATIC SPRI | 1 | LEVEL UP DEVELOPMENT, LLC | 19125 |
| Issued Jun 16, 2026 | 2001 E LEHIGH AVE | New Construction or AdditionsInstall two 10" sanitary curb traps, one 12" storm curb trap, 4" domestic water service, 6" vents and 12" & 10" building drains. | — | Lepore Plumbing & Sons Inc | C | 19125 |
| Issued Jun 16, 2026 | 18 E COLUMBIA AVE | Alterations3 toilets 2 tubs 1 shower 2 single vanities 1 double vanity 1 laundry tub 1 kitchen sink 1 40 gallon Water Heater Backyard and front yard hose bib 1 refrigerator box 1 washer and dryer on 2nd bathroom | — | SHEGDA CONSTRUCTION CORP | 19125 |
| Issued Jun 16, 2026 | 2672 BRADDOCK ST | ExcavationSite / Utility Permit for CP-2025-001695 FOR EXCAVATION AND BACKFILL OF SITE AND INSTALLATION OF RELATED STABILIZATION MEASURES. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. ** SEE BUILDING PERMIT FOR ALL STRUCTURAL WORK ** **PROJECT INCLUDES UNDERPINNING VIA AMENDMENT TO CP-2025-001695 AND INCLUDED IN THIS PERMIT ** | — | TIR EAGHAIN CONSTRUCTION INC | C | 19125 |
| Issued Jun 16, 2026 | 1630 E HEWSON ST | Addition and/or AlterationINTERIOR RENOVATIONS AND FOR THE ERECTION OF ONE STORY ADDITION ABOVE THE EXISTING SECOND FLOOR REAR AS PART OF AN EXISTING ATTACHED STRUCTURE. DETAILS AS SHOWN IN THE APPLICATION / PLAN. | — | Subversive Building Services LLC | 19125 |
| Issued Jun 16, 2026 | 1411 E OXFORD ST | New ConstructionFOR THE ERECTION OF A FOUR (4) STORY ATTACHED STRUCTURE OF TYPE III-B CONSTRUCTION SLAB ON GRADE, A ROOF DECK AT THE 4TH FLOOR ACCESSED BY THE 4TH FLOOR FRONT, A ROOF DECK AT THE 3RD FLOOR ACCESSED BY THE 3RD FLOOR REAR, A ROOF DECK AT THE 2ND FLOOR ACCESSED BY THE 2ND FLOOR REAR. FOR USE AS A SINGLE-FAMILY DWELLING (GROUP R-3) WITH THREE (3) ACCESSORY OFF STREET SURFACE PARKING SPACES ACCESSED BY A SHARED DRIVE AISLE. BUILDING TO BE FULLY SPRINKLERED WITH A MINIMUM OF AN NFPA 13R AUTOMATIC SPRI | 1 | LEVEL UP DEVELOPMENT, LLC | 19125 |
| Issued Jun 16, 2026 | 1900 E HUNTINGDON ST | Full Demolitioncomplete demolition to create vacant lot | — | A2 Design Group LLC | C | 19125 |
| Issued Jun 16, 2026 | 2235 RITTER ST | AlterationsREPAIR/REPLACE CT & FAI. | — | BARTHOLOMEW N EMANUEL | 19125 |
| Issued Jun 16, 2026 | 2233 RITTER ST | AlterationsReplace 5" curb trap with fresh air inlet. Replace 3/4" water service from the curb to the foundation wall. | — | BARTHOLOMEW N EMANUEL | 19125 |
| Issued Jun 16, 2026 | 2600-04 KENSINGTON AVE | New construction, addition, GFA changeFOR THE ERECTION OF AN ADDITION TO AN EXISTING TRANSIT STATION. SIZE AND LOCATION AS SHOWN IN PLANS. **NO SIGNS APPROVED ON THIS APPLICATION.** | — | SEPTA | C | 19125 |
| Issued Jun 16, 2026 | 135 E CUMBERLAND ST | New ConstructionFOR THE ERECTION OF AN ATTACHED STRUCTURE WITH A ROOF DECK AND PILOT HOUSE. STRUCTURE FOR USE AS SINGLE FAMILY HOUSEHOLD LIVING. SPRINKLERED THROUGHOUT PER NFPA 13D. SEPARATE PERMITS REQUIRED FOR PLUMBING, MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED IN ACCORDANCE WITH SECTION 3306 OF THE IBC. | 1 | CUS CONSTRUCTION INC | 19125 |
| Issued Jun 16, 2026 | 2542 E YORK ST | Change of UseLimited Lodging | — | — | 19125 |
| Issued Jun 15, 2026 | 2235 TAGGERT ST | New ConstructionMechanical / Fuel Gas Permit for combo RP-2026-002055 | — | LEGENDAIR LLC | 19125 |
| Issued Jun 15, 2026 | 2558 FRANKFORD AVE | New ConstructionFOR THE ERECTION OF A THREE (3) STORY ATTACHED STRUCTURE OF TYPE V-B CONSTRUCTION FOR USE AS VACANT COMMERCIAL SPACE (SEPARATE PERMITS REQUIRED PRIOR TO FIT-OUT AND ISSUANCE OF C.O.) AND TWO (2) DWELLING UNITS (GROUP R-3). BUILDING TO BE FULLY SPRINKLERED PER NFPA 13 THROUGHOUT THE COMMERCIAL SPACE (BASEMENT & 1ST FLOOR) AND PER NFPA 13R THROUGHOUT THE GROUP R-3 OCCUPANCY (2ND & 3RD FLOORS). ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IBC. SEPARATE PERMITS REQUIRED FOR MEC | 2 | FIDAN BASHA | C | 19125 |
| Issued Jun 15, 2026 | 2317 AMBER ST | New ConstructionFOR THE ERECTION OF A THREE (3) STORY ATTACHED STRUCTURE OF TYPE V-B CONSTRUCTION WITH BASEMENT, ROOF DECK, AND ROOF DECK ACCESS STRUCTURE (ENCLOSED ACCESS STAIRS ONLY). FOR USE AS A SINGLE-FAMILY DWELLING. BUILDING TO BE FULLY SPRINKLERED WITH A MINIMUM OF A NFPA 13D AUTOMATIC SPRINKLER SYSTEM. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IRC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. ENERGY CODE COMPLIANCE IN ACCORDANCE WIT | 1 | ROCI JIMMY | 19125 |