Permits (as owner)
14 entries
- Issued Nov 19, 2025
EZ Wall Covering Replacement · EZ EXTERIOR WALL COVERINGS - For the Applications of Exterior Wall Coverings as per attached standards. Deviations from these standards shall result in permit revocation and require submission of construction and site plans. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work. Ins
- Issued Oct 23, 2025
Addition and/or Alterations · FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.
- Issued Oct 22, 2025
Addition and/or Alterations · FOR NEW MECHANICAL SYSTEM INSTALLATION. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS.** ALL WORK TO BE DONE PER APPROVED PLANS. **IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.** SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.**
- Issued Oct 20, 2025
Addition and/or Alteration · INSTALL 400 AMP ELECTRICAL SERVICE AND 4 METER PACKS WITH PROPER GROUNDING AND BONDING 1/0 COLD WATER GROUND. INSTALL ONE 100 AMP SUBPANELS FOR HOUSE, ONE 200 AMP SUBPANEL FOR THE COMMERCIAL SPACE AND TWO 125 AMP SUBPANEL FOR EACH OF THE 2 DWELLING UNITS. INSTALL WIRING, LIGHTING, SWITCHES EMERGENCY LIGHTING AND RECEPTACLE OUTLETS. INSTALL INTERCONNECTED SMOKE AND CO ALARMS. INSTALL FIRE ALARM SYSTEM. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC, 2016 NFPA 72 AND PER PLANS. Amendment
- Issued Oct 15, 2025
Addition and/or Alteration · INSTALL 400 AMP ELECTRICAL SERVICE AND 4 METER PACKS WITH PROPER GROUNDING AND BONDING. INSTALL ONE 100 AMP SUBPANELS FOR HOUSE, ONE 200 AMP SUBPANEL FOR THE COMMERCIAL SPACE AND TWO 125 AMP SUBPANEL FOR EACH OF THE 2 DWELLING UNITS. INSTALL WIRING, LIGHTING, SWITCHES EMERGENCY LIGHTING AND RECEPTACLE OUTLETS. INSTALL INTERCONNECTED SMOKE AND CO ALARMS. INSTALL FIRE ALARM SYSTEM. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC, 2016 NFPA 72, AND PER PLANS.
- Issued Sep 30, 2025
Alterations · INTERIOR ALTERATION TO MIXED USE BUILDING. INTERRIOR INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR LISTED FIXTURES CONNECTING TO EXISTING METALLIC PIPING. ALL PIPING SERVING AND LOCATED IN COMMERCIAL SPACE SHALL BE METALLIC TO ROOF EXTENSION. VENTING TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTION 919 PHILADELPHIA SINGLE STACK VENT SYSTEM. ALL WOR TO BE PERFORMED IN STRICT COMPLIANCE WITH 2018 PPC AND APPROVED PLANS.
- Issued Sep 30, 2025
Alterations · Install drain lines and waterlines and set fixture.
- Issued Sep 15, 2025
Addition and/or Alterations · INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 & 13R THROUGHOUT THE BUILDING TO INCLUDE 2" MAIN FIRE SERVICE LINE WITH A 2" WILKINS 950XTL2 BACKFLOW PREVENTION ASSEMBLY AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.
- Issued Sep 15, 2025
Addition and/or Alterations · INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 & 13R THROUGHOUT THE BUILDING TO INCLUDE 2" MAIN FIRE SERVICE LINE WITH A 2" WILKINS 950XTL2 BACKFLOW PREVENTION ASSEMBLY AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.
- Issued Sep 2, 2025
Addition and/or Alterations · INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13R THROUGHOUT AN EXISTING STRUCTURE. INSTALLATION TO INCLUDE 2" FIRE SERVICE LINE AND 2." DC WILKINS 950 XLT2 BACKFLOW PREVENTION ASSEMBLY AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.
- Issued Jul 25, 2025
Rough-In · Rough-In Permit for FP-2025-001495 To install a water base sprinkler system for a mixed-use building according to the designed plan.
- Issued Jul 25, 2025
Rough-In · Rough-In Permit for FP-2025-001494 To install a wet sprinkler system for a mixed-use building according to the designed plan.
Track this owner
We'll flag their next deal, permit, or filing — usually before the neighbors know.
Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.