15 entries
- Issued Jul 7, 2026
Addition and/or Alteration · Install a new Fire Alarm System ***ALL WORK PER APPROVED PLANS NEC 2017 NFPA2016***
- Issued Jul 7, 2026
Addition and/or Alteration · Install fire alarm system as per 2016 NFPA 72.
- Issued May 16, 2026
New Construction · Scope of Work: Provide all labor, materials, equipment, and supervision necessary to supply and install the complete electrical system in accordance with the Owner’s Scope of Work dated Wednesday, December 3, 2025, the referenced construction documents, the National Electrical Code, and all applicable local codes and authorities having jurisdiction. Included Scope: • PECO temporary service application and associated fees • Temporary power outlets on all floors • Temporary lighting in stairwells
- Issued May 16, 2026
Addition and/or Alteration · -NOTED :TAMPER RESISTANT RECEPTACLES & FLOOR RECEPTACLE IN MULTI-PURPOSE RM. • Supply and install all electrical wiring as per approved plans on the first floor and second floor of the addition. • Supply and install all fire alarm wiring on the first floor and second floor, tied into the existing fire alarm system. • Supply and install service installation to a new 100A panel located in the first floor hallway, fed from the existing service in the basement of the existing building. • supply and
- Issued May 6, 2026
Addition and/or Alteration · Scope of Work Hassan Electric LLC will provide a complete electrical installation for the project including: New 200 Amp electrical service • 200A main breaker panel and full grounding system • 60 LED recessed lights (4") • 55 duplex outlets and 30 switches • Arc fault and GFCI protection as required by code • 3 bathroom exhaust fans Smoke and carbon monoxide detection system Wiring for 2 indoor HVAC systems and 2 outdoor condensers • Complete appliance hookups • All wiring installed throughout
- Issued Apr 29, 2026
Addition and/or Alteration · Scope of Work – Tenant Vanilla Box: • Supply and install all electrical wiring throughout tenant space • Supply and install all electrical service equipment and associated wiring • Supply and install all indoor and outdoor electrical systems as per plans • Supply and install all fire alarm wiring and equipment as per plans • Hassan Electric will supply all lighting fixtures as per plans • Hassan Electric will supply and install heaters as per plans • All required permits and inspections are incl
- Issued Apr 20, 2026
New Construction · Install a new 4000-amp electrical service to serve forty (40) dwelling units and three (3) commercial spaces. Work includes installation of service conductors, metering equipment, service disconnects, and proper grounding and bonding. All service disconnects and metering shall be clearly labeled and numbered in accordance with the approved plans. Provide complete electrical distribution throughout the building, including installation of all wiring (indoor and outdoor), lighting fixtures, swit
- Issued Apr 14, 2026
Addition and/or Alteration · Furnish and install electric for (2) bathrooms To include Wire and install (2) single pole switches Wire and install (2) LED high hats Wire and install (2) emergency wall packs Wire and install (2) GFCI outlets Wire and install power for (1) booster pump
- Issued Jan 13, 2026
New Construction · Scope of Work (Supply & Install) Electrical Service & Distribution • New 200A electrical service • New 40-circuit panel • Complete grounding and bonding • AFCI and GFCI protection per NEC and local code Interior Lighting • 4” LED recessed lighting throughout hallways, stairs, bedrooms, living room, kitchen, and garage Devices • Outlets and switches throughout per code • All white Decora devices Closets & Bathrooms • Motion sensor lighting in all closets • Bathrooms to include recessed lightin
- Issued Jan 2, 2026
Addition and/or Alteration · -Furnish and install: -second floor add (2) additional recessed lights in the training area -remove and dispose of existing 4' LED fixtures- safe off -Install dimmer switch to control recessed lighting in training area -Add (2) 15" ceiling fixtures over the reception area, controlled by dimmer -Furnish and install: -demo all existing hanging MC wiring and lighting from the current 3rd flr office space -reconnect lighting and power circuits for existing rooms -remove all old lighting fixtu
- Issued Nov 21, 2025
New Construction · AMENDED 3/23/26 TEMPORARY SERVICE 200 AMPS OR LESS 800 amp service installation. Vacant commercial spaces Wring of 6 dwelling units Fire alarm installation throughout in accordance with NFPA 72 2016 & The Philadelphia Fire Code 2018. **ELECTRICAL PERMIT REQ'D FOR FITOUT OF COMMERCIAL SPACES -A SERVICE CALC WAS NOT SUPPLIED FOR COMMERCIAL SPACES (VACANT CALC ONLY) A NEW SERVICE CALC WILL BE NEEDED FOR FUTURE USES**
- Issued Nov 17, 2025
Addition and/or Alteration · Adapt the fire alarm to the new floor plan. Relocate existing fire alarm devices. Add new notification power supply and notification devices to properly protect the suite within the building. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.
Track this owner
We'll flag their next deal, permit, or filing — usually before the neighbors know.
Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.