Belles Electrical Contractors LLC
17 permits
- Records on file
- 17
Built (as contractor)
17 entries
- Issued Jul 9, 2026
Addition and/or Alteration · Furnish and install thirty Category 6 plenum cables from the Server Room to workstations. Average cable pull is 175-feet.
- Issued Jun 29, 2026
Addition and/or Alteration · Perform an electrical fit-out for a commercial office space on the 30th floor, including a complete rewiring of the space. Provide complete electrical distribution, including the installation of lighting fixtures, switches, lighting controls, exit signs, emergency lighting, telecommunications wiring, and receptacle outlets. Install dedicated branch circuits and electrical connections to supply power for heat pumps, water heater, fan-powered variable (FPV) units, and poke-through devices,
- Issued Jun 17, 2026
Addition and/or Alteration · Furnish and install eighty-two (82) Category 6 plenum cables from an existing IDF to workstations. Average cable pull is 185 feet.
- Issued Jun 17, 2026
Addition and/or Alteration · Furnish and install two (2) Category 6 plenum cables to fourteen (14) wall locations. Average cable pull is 180 feet.
- Issued May 12, 2026
Addition and/or Alteration · Furnish and install seventy-two (72) Category 6 plenum rated cables to workstations.
- Issued May 12, 2026
Addition and/or Alteration · Furnish and install thirty-seven (37) Category 6 plenum cables from the existing server room to new workstations
- Issued Apr 23, 2026
Addition and/or Alteration · Furnish and install sixty-three (63) Category 6 cables from the Server Room to new workstations. Average Cable pull is 160 feet.
- Issued Apr 13, 2026
Addition and/or Alteration · Furnish and install 24 Category 6A cables from GCB-3 Rack to Server Room. Furnish and install 18 strands of fiber from GCB-3 Rack to Server Room. Furnish and install 36 OS2 LC Connectors. Furnish and install 12 SDI cables from GCb-3 Rack to Server Room. Furnish and install all necessary fiber enclosures and connectors. Furnish and install all necessary copper, and BNC patch panels and connectors.
- Issued Mar 6, 2026
Addition and/or Alteration · Furnish and install eighty (80) Category 6 plenum cables from the IT Room to workstations.
- Issued Feb 27, 2026
Addition and/or Alteration · Install telecommunications wiring for office space, including low-voltage cabling, raceways, back boxes, terminations, and supports as required. All work to be performed in accordance with the 2017 NEC.
- Issued Feb 16, 2026
Addition and/or Alteration · Install (18) A1 light fixtures Install (4) A2 light fixtures Install (12) A17 light fixtures Install (11) B1 light fixtures Furnish and install (8) F1 light fixtures Furnish and install (2) F2 light fixtures Furnish and install (2) F3 light fixtures Furnish and install (1) F4 light fixtures Furnish and install (344') T1 track Install (36') relocated T2 track Relocate (6) pendant lights Install (4) pendant mounted exit signs Relocate (7) fire alarm devices Install (5) fire alarm speaker strobes I
- Issued Nov 14, 2025
Addition and/or Alteration · Furnish and install one-hundred seventy-eight (178) plenum Category 6 cables from the MDF room to workstations. Furnish and install fourteen (14) plenum Category 6A cables from the MDF to wireless access points. Average cable pull is 150 feet.
- Issued Oct 23, 2025
Addition and/or Alteration · Furnish and install two-hundred and sixteen (216) plenum Category 6 cables to nine (9) different IT Closets.
- Issued Sep 30, 2025
Addition and/or Alteration · Relocate light fixtures as required. Furnish and install (10) Lithonia 2FLS4 2X4 LED's Furnish and install (2) ceiling motion sensors Furnish and install (1) power pack lighting relay Furnish and install (2) LED dimming switches Furnish and install (9) 120V, 20A receptacles Furnish and install (10) 120V, 20A dedicated GFCI Receptacles-2017 NEC.
- Issued Aug 13, 2025
Addition and/or Alteration · Furnish and install twenty-eight (28) Category 6 plenum cables from Server Room to various locations throughout building. Average cable pull is 175 feet. Furnish only banana cable for security vendor to install devices on doors. Eleven total. Average cable pull is 175 feet.
- Issued Aug 5, 2025
Addition and/or Alteration · Furnish and install nine (9) Category 6 plenum cables from the IT Room to workstations. Average cable pull is 150 feet. Provide labor to fish existing cabling and terminate on Category 6 jacks.
- Issued Jul 24, 2025
Addition and/or Alteration · Furnish and install plenum OS2 from Server room to multiple racks on the gaming floor. Average cable pull is 175 feet Furnish and install seventy-four (74) plenum Category 6A cables from the Server Room to various camera and wireless locations on the gaming floor. Average cable pull is 175 feet Furnish and install two-hundred-sixteen (216) plenum Category 6A cables from various racks on gaming floor to below raised floor. Average cable pull is 50 feet
Track this owner
We'll flag their next deal, permit, or filing — usually before the neighbors know.
Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.