56 sold · 86 permits · 1 violation
- Records on file
- 143
Sold
56 entries
- Recorded Oct 14, 2025
$280K
to DA SILVA CORREIA VICTORIA A;DA SILVA CORREIA FRANCISCO M
- Recorded Oct 29, 2024
$342K
to SALAZAR ENRIQUEZ EDGAR R;TAVAREZ ESTEVEZ EVELING ADALGISA
Permits (as owner)
86 entries
- Issued Apr 15, 2026
New Construction · Electrical Permit for combo RP-2025-007684 EZELEC - NEW SERVICE ELECTRICAL WIRING/DEVICES THROUGHOUT AS PER 2017 NEC. Deviations from the EZ Permit standards require submission of construction and site plans.
- Issued Apr 15, 2026
New Construction · Electrical Permit for combo RP-2025-007676 EZELEC - NEW SERVICE ELECTRICAL WIRING/DEVICES THROUGHOUT AS PER 2017 NEC. Deviations from the EZ Permit standards require submission of construction and site plans.
- Issued Mar 30, 2026
1 units
New Construction · FOR THE ERECTION OF A THREE (3) STORY ATTACHED STRUCTURE OF TYPE V-B CONSTRUCTION FOR USE AS A SINGLE-FAMILY DWELLING (GROUP R-3). BUILDING TO BE FULLY SPRINKLERED PER NFPA 13D. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IRC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, FIRE SUPPRESSION, AND EXCAVATION WORK. ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C.O., SUBMITTAL OF AIR BARRIER CHECKLIST AND ENVELOPE TESTING CERTIFICATE
- Issued Mar 9, 2026
New Construction or Additions · Plumbing Permit (Exterior Building Drainage) for combo RP-2025-007684
- Issued Mar 9, 2026
New Construction or Additions · Plumbing Permit (Exterior Building Drainage) for combo RP-2025-007676
- Issued Mar 9, 2026
New Construction or Additions · Plumbing Permit (Water Distribution) for combo RP-2025-007676
- Issued Mar 9, 2026
New Construction or Additions · Plumbing Permit (Water Distribution) for combo RP-2025-007684
- Issued Jan 7, 2026
New Construction or Additions · Plumbing Permit (Water Distribution) for combo RP-2025-007712
- Issued Jan 7, 2026
New Construction or Additions · Plumbing Permit (Water Distribution) for combo RP-2025-007690
- Issued Jan 7, 2026
New Construction or Additions · Plumbing Permit (Water Distribution) for combo RP-2025-007711
- Issued Jan 7, 2026
New Construction or Additions · Plumbing Permit (Exterior Building Drainage) for combo RP-2025-007688
- Issued Jan 7, 2026
New Construction or Additions · Plumbing Permit (Exterior Building Drainage) for combo RP-2025-007690
- Issued Jan 7, 2026
New Construction or Additions · Plumbing Permit (Water Distribution) for combo RP-2025-007688
- Issued Jan 7, 2026
New Construction or Additions · Plumbing Permit (Exterior Building Drainage) for combo RP-2025-007711
- Issued Jan 7, 2026
New Construction or Additions · Plumbing Permit (Exterior Building Drainage) for combo RP-2025-007710
- Issued Jan 7, 2026
New Construction or Additions · Plumbing Permit (Water Distribution) for combo RP-2025-007710
- Issued Jan 7, 2026
New Construction or Additions · Plumbing Permit (Exterior Building Drainage) for combo RP-2025-007712
- Issued Dec 30, 2025
New Construction · Electrical Permit for combo RP-2025-007710 EZELEC - NEW SERVICE ELECTRICAL WIRING/DEVICES THROUGHOUT AS PER 2017 NEC. Deviations from the EZ Permit standards require submission of construction and site plans.
- Issued Dec 30, 2025
New Construction · Electrical Permit for combo RP-2025-007688 EZELEC - NEW SERVICE ELECTRICAL WIRING/DEVICES THROUGHOUT AS PER 2017 NEC. Deviations from the EZ Permit standards require submission of construction and site plans.
- Issued Dec 30, 2025
New Construction · Electrical Permit for combo RP-2025-007690 EZELEC - NEW SERVICE ELECTRICAL WIRING/DEVICES THROUGHOUT AS PER 2017 NEC. Deviations from the EZ Permit standards require submission of construction and site plans.
- Issued Dec 22, 2025
New Construction · Electrical Permit for combo RP-2025-007712 EZELEC - NEW SERVICE ELECTRICAL WIRING/DEVICES THROUGHOUT AS PER 2017 NEC. Deviations from the EZ Permit standards require submission of construction and site plans.
- Issued Dec 22, 2025
New Construction · Electrical Permit for combo RP-2025-007711 EZELEC - NEW SERVICE ELECTRICAL WIRING/DEVICES THROUGHOUT AS PER 2017 NEC. Deviations from the EZ Permit standards require submission of construction and site plans.
- Issued Dec 22, 2025
New Construction · Electrical Permit for combo RP-2025-007714 EZELEC - NEW SERVICE ELECTRICAL WIRING/DEVICES THROUGHOUT AS PER 2017 NEC. Deviations from the EZ Permit standards require submission of construction and site plans.
- Issued Dec 22, 2025
New Construction · Electrical Permit for combo RP-2025-007718 EZELEC - NEW SERVICE ELECTRICAL WIRING/DEVICES THROUGHOUT AS PER 2017 NEC. Deviations from the EZ Permit standards require submission of construction and site plans.
- Issued Dec 5, 2025
New Construction · FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM THROUGHOUT A THREE (3) STORY SINGLE-FAMILY DWELLING TO INCLUDE A ONE (1) INCH COMBINED DOMESTIC AND FIRE SERVICE LINE. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH NFPA 13D BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. SEE RP-2025-007711 FOR ASSOCIATED BUILDING PERMIT.
- Issued Dec 5, 2025
New Construction · FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM THROUGHOUT A THREE (3) STORY SINGLE-FAMILY DWELLING TO INCLUDE A ONE (1) INCH COMBINED DOMESTIC AND FIRE SERVICE LINE. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH NFPA 13D BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. SEE RP-2025-007710 FOR ASSOCIATED BUILDING PERMIT.
- Issued Dec 5, 2025
New Construction · FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM THROUGHOUT A THREE (3) STORY SINGLE-FAMILY DWELLING TO INCLUDE A ONE (1) INCH COMBINED DOMESTIC AND FIRE SERVICE LINE. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH NFPA 13D BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. SEE RP-2025-007718 FOR ASSOCIATED BUILDING PERMIT.
- Issued Dec 5, 2025
New Construction · FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM THROUGHOUT A THREE (3) STORY SINGLE-FAMILY DWELLING TO INCLUDE A ONE (1) INCH COMBINED DOMESTIC AND FIRE SERVICE LINE. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH NFPA 13D BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. SEE RP-2025-007714 FOR ASSOCIATED BUILDING PERMIT.
- Issued Dec 5, 2025
New Construction · FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM THROUGHOUT A THREE (3) STORY SINGLE-FAMILY DWELLING TO INCLUDE A ONE (1) INCH COMBINED DOMESTIC AND FIRE SERVICE LINE. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH NFPA 13D BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. SEE RP-2025-007712 FOR ASSOCIATED BUILDING PERMIT.
- Issued Dec 4, 2025
New Construction · FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM THROUGHOUT A THREE (3) STORY SINGLE-FAMILY DWELLING TO INCLUDE A ONE (1) INCH COMBINED DOMESTIC AND FIRE SERVICE LINE. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH NFPA 13D BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. SEE RP-2025-007690 FOR ASSOCIATED BUILDING PERMIT.
- Issued Dec 4, 2025
New Construction · FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM THROUGHOUT A THREE (3) STORY SINGLE-FAMILY DWELLING TO INCLUDE A ONE (1) INCH COMBINED DOMESTIC AND FIRE SERVICE LINE. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH NFPA 13D BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. SEE RP-2025-007676 FOR ASSOCIATED BUILDING PERMIT.
- Issued Dec 4, 2025
New Construction · FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM THROUGHOUT A THREE (3) STORY SINGLE-FAMILY DWELLING TO INCLUDE A ONE (1) INCH COMBINED DOMESTIC AND FIRE SERVICE LINE. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH NFPA 13D BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. SEE RP-2025-007688 FOR ASSOCIATED BUILDING PERMIT.
- Issued Dec 4, 2025
New Construction · FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM THROUGHOUT A THREE (3) STORY SINGLE-FAMILY DWELLING TO INCLUDE A ONE (1) INCH COMBINED DOMESTIC AND FIRE SERVICE LINE. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH NFPA 13D BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. SEE RP-2025-007684 FOR ASSOCIATED BUILDING PERMIT.
- Issued Nov 18, 2025
New Construction · Mechanical / Fuel Gas Permit for combo RP-2025-004271
- Issued Nov 18, 2025
New Construction · Mechanical / Fuel Gas Permit for combo RP-2025-003521
- Issued Oct 27, 2025
New Construction or Additions · Plumbing Permit (Interior) for combo RP-2025-007676
- Issued Oct 27, 2025
New Construction or Additions · Plumbing Permit (Interior) for combo RP-2025-007684
- Issued Oct 27, 2025
New Construction or Additions · Plumbing Permit (Interior) for combo RP-2025-007690
- Issued Oct 27, 2025
New Construction or Additions · Plumbing Permit (Interior) for combo RP-2025-007710
- Issued Oct 27, 2025
New Construction or Additions · Plumbing Permit (Interior) for combo RP-2025-007712
- Issued Oct 27, 2025
New Construction or Additions · Plumbing Permit (Interior) for combo RP-2025-007711
- Issued Oct 27, 2025
New Construction or Additions · Plumbing Permit (Interior) for combo RP-2025-007688
- Issued Oct 20, 2025
New Construction or Additions · Plumbing Permit (Water Distribution) for combo RP-2025-007714
- Issued Oct 20, 2025
New Construction or Additions · Plumbing Permit (Water Distribution) for combo RP-2025-007718
- Issued Oct 20, 2025
New Construction or Additions · Plumbing Permit (Exterior Building Drainage) for combo RP-2025-007718
- Issued Oct 20, 2025
New Construction or Additions · Plumbing Permit (Interior) for combo RP-2025-007714
- Issued Oct 20, 2025
New Construction or Additions · Plumbing Permit (Exterior Building Drainage) for combo RP-2025-007714
- Issued Oct 20, 2025
New Construction or Additions · Plumbing Permit (Interior) for combo RP-2025-007718
- Issued Oct 9, 2025
New Construction · Mechanical / Fuel Gas Permit for combo RP-2025-007718 EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and/or Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans.
- Issued Oct 9, 2025
New Construction · Mechanical / Fuel Gas Permit for combo RP-2025-007676 EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and/or Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans.
- Issued Oct 9, 2025
New Construction · Mechanical / Fuel Gas Permit for combo RP-2025-007688 EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and/or Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans.
- Issued Oct 9, 2025
New Construction · Mechanical / Fuel Gas Permit for combo RP-2025-007710 EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and/or Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans.
- Issued Oct 9, 2025
New Construction · Mechanical / Fuel Gas Permit for combo RP-2025-007714 EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and/or Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans.
- Issued Oct 9, 2025
New Construction · Mechanical / Fuel Gas Permit for combo RP-2025-007684 EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and/or Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans.
- Issued Oct 9, 2025
New Construction · Mechanical / Fuel Gas Permit for combo RP-2025-007712 EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and/or Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans.
- Issued Oct 9, 2025
New Construction · Mechanical / Fuel Gas Permit for combo RP-2025-007711 EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and/or Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans.
- Issued Oct 9, 2025
New Construction · Mechanical / Fuel Gas Permit for combo RP-2025-007690 EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and/or Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans.
- Issued Oct 8, 2025
1 units
New Construction · FOR THE ERECTION OF A TYPE V-B ATTACHED THREE (3) STORY STRUCTURE (BASEMENT WITH 1ST FLOOR MORE THAN SIX (6) FEET ABOVE GRADE PLANE) FOR USE AS A SINGLE-FAMILY DWELLING (GROUP R-3). BUILDING TO BE FULLY SPRINKLERED PER NFPA 13D. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IRC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C.O., SUBMITTAL OF AIR BARRIER CHE
- Issued Oct 8, 2025
1 units
New Construction · FOR THE ERECTION OF A TYPE V-B ATTACHED THREE (3) STORY STRUCTURE (BASEMENT WITH 1ST FLOOR MORE THAN SIX (6) FEET ABOVE GRADE PLANE) FOR USE AS A SINGLE-FAMILY DWELLING (GROUP R-3). BUILDING TO BE FULLY SPRINKLERED PER NFPA 13D. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IRC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C.O., SUBMITTAL OF AIR BARRIER CHE
- Issued Oct 8, 2025
1 units
New Construction · FOR THE ERECTION OF A TYPE V-B ATTACHED THREE (3) STORY STRUCTURE (BASEMENT WITH 1ST FLOOR MORE THAN SIX (6) FEET ABOVE GRADE PLANE) FOR USE AS A SINGLE-FAMILY DWELLING (GROUP R-3). BUILDING TO BE FULLY SPRINKLERED PER NFPA 13D. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IRC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C.O., SUBMITTAL OF AIR BARRIER CHE
- Issued Oct 8, 2025
1 units
New Construction · FOR THE ERECTION OF A TYPE V-B ATTACHED THREE (3) STORY STRUCTURE (BASEMENT WITH 1ST FLOOR MORE THAN SIX (6) FEET ABOVE GRADE PLANE) FOR USE AS A SINGLE-FAMILY DWELLING (GROUP R-3). BUILDING TO BE FULLY SPRINKLERED PER NFPA 13D. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IRC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C.O., SUBMITTAL OF AIR BARRIER CHE
- Issued Oct 8, 2025
1 units
New Construction · FOR THE ERECTION OF A TYPE V-B THREE (3) STORY STRUCTURE (BASEMENT WITH 1ST FLOOR MORE THAN SIX (6) FEET ABOVE GRADE PLANE) FOR USE AS A SINGLE-FAMILY DWELLING (GROUP R-3). BUILDING TO BE FULLY SPRINKLERED PER NFPA 13D. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IRC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C.O., SUBMITTAL OF AIR BARRIER CHECKLIST AN
- Issued Oct 8, 2025
1 units
New Construction · FOR THE ERECTION OF A TYPE V-B ATTACHED THREE (3) STORY STRUCTURE (BASEMENT WITH 1ST FLOOR MORE THAN SIX (6) FEET ABOVE GRADE PLANE) FOR USE AS A SINGLE-FAMILY DWELLING (GROUP R-3). BUILDING TO BE FULLY SPRINKLERED PER NFPA 13D. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IRC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C.O., SUBMITTAL OF AIR BARRIER CHE
- Issued Oct 8, 2025
1 units
New Construction · FOR THE ERECTION OF A TYPE V-B ATTACHED THREE (3) STORY STRUCTURE (BASEMENT WITH 1ST FLOOR MORE THAN SIX (6) FEET ABOVE GRADE PLANE) FOR USE AS A SINGLE-FAMILY DWELLING (GROUP R-3). BUILDING TO BE FULLY SPRINKLERED PER NFPA 13D. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IRC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C.O., SUBMITTAL OF AIR BARRIER CHE
- Issued Oct 8, 2025
1 units
New Construction · FOR THE ERECTION OF A TYPE V-B ATTACHED THREE (3) STORY STRUCTURE (BASEMENT WITH 1ST FLOOR MORE THAN SIX (6) FEET ABOVE GRADE PLANE) FOR USE AS A SINGLE-FAMILY DWELLING (GROUP R-3). BUILDING TO BE FULLY SPRINKLERED PER NFPA 13D. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IRC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C.O., SUBMITTAL OF AIR BARRIER CHE
- Issued Oct 8, 2025
1 units
New Construction · FOR THE ERECTION OF A TYPE V-B ATTACHED THREE (3) STORY STRUCTURE (BASEMENT WITH 1ST FLOOR MORE THAN SIX (6) FEET ABOVE GRADE PLANE) FOR USE AS A SINGLE-FAMILY DWELLING (GROUP R-3). BUILDING TO BE FULLY SPRINKLERED PER NFPA 13D. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IRC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C.O., SUBMITTAL OF AIR BARRIER CHE
- Issued Sep 26, 2025
New Construction · FOR THE INSTALLATION OF AN AUTOMATIC FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13D THROUGHOUT THREE STORY BUILDING TO INCLUDE 1-INCH COMBINED WATER SERVICE LINE AS PER APPROVED PLANS. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.
- Issued Sep 26, 2025
New Construction · INSTALLATION OF RESIDENTIAL FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13D THROUGHOUT A THREE (3) STORY STRUCTURE WITH BASEMENT AND PILOT HOUSE. THIS IS A MULTI-PURPOSE SYSTEM UTILIZING A COMBINED ONE INCH (1") DOMESTIC AND FIRE SERVICE LINE WITH REMOTE TOILET CONNECTION PER PLANS. SEPARATE PERMITS REQUIRED FOR ALL PLUMBING WORK.
- Issued Sep 25, 2025
New Construction or Additions · Plumbing Permit (Interior) for combo RP-2025-004271
- Issued Sep 25, 2025
New Construction or Additions · Plumbing Permit (Exterior Building Drainage) for combo RP-2025-004271
- Issued Sep 25, 2025
New Construction or Additions · Plumbing Permit (Water Distribution) for combo RP-2025-003521
- Issued Sep 25, 2025
New Construction or Additions · Plumbing Permit (Water Distribution) for combo RP-2025-004271
- Issued Sep 25, 2025
New Construction or Additions · Plumbing Permit (Exterior Building Drainage) for combo RP-2025-003521
- Issued Sep 25, 2025
New Construction or Additions · Plumbing Permit (Interior) for combo RP-2025-003521
- Issued Aug 7, 2025
New Construction or Additions · Plumbing Permit (Water Distribution) for combo RP-2024-011697
- Issued Aug 7, 2025
New Construction · FOR INSTALLATION OF A ONE-INCH COMBINED FIRE/DOMESTIC WATER SERVICE LINE AND FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH APPROVED PLANS, HYDRAULIC CALCULATIONS AND NFPA 13D.
- Issued Aug 7, 2025
New Construction or Additions · Plumbing Permit (Exterior Building Drainage) for combo RP-2024-011697
- Issued Jul 22, 2025
New construction, addition, GFA change · FOR THE ERECTION OF AN ATTACHED STRUCTURE. SIZE AND LOCATION AS SHOWN IN THE APPLICATION / PLANS. *AMEND 9/23/25; REVISE FRONT STAIRS*
- Issued Jul 22, 2025
New construction, addition, GFA change · **AMENDMENT APPROVED ON 9/18/25: TO AMENDMENT PREVIOUSLY APPROVED ZONING PERMIT # ZP-2025-005280, TO DOCUMENT THE CHANGE TO FRONT STEPS ON SIDEWALK, CITY STREET DEPARTMENT APPROVAL REQUIRES ANY ENCROACHMENT TO WALK PRIOR TO ISSUE ANY BUILDING PERMIT; AND THE REMAINING PERMIT SAME AS PREVIOUSLY APPROVED. SIZE AND LOCATION AS SHOWN ON THE PLANS** FOR THE ERECTION OF AN ATTACHED NEW STRUCTURE WITH CELLAR. SIZE AND LOCATION AS SHOWN IN THE APPLICATION / PLAN.
- Issued Jul 22, 2025
New construction, addition, GFA change · **AMENDMENT APPROVED ON 9/19/2025: TO AMENDMENT PREVIOUSLY APPROVED ZONING PERMIT # ZP-2025-005291, TO DOCUMENT THE CHANGE TO THE OUTSIDE FRONT STEPS ONLY, (CITY STREET DEPARTMENT APPROVAL REQUIRE PRIOR TO ISSUE BUILDING PERMIT) AND THE REMAINING PERMIT SAME AS PREVIOUSLY APPROVED. SIZE AND LOCATION AS SHOWN ON THE PLANS** FOR THE ERECTION OF AN ATTACHED NEW STRUCTURE WITH CELLAR. SIZE AND LOCATION AS SHOWN IN THE APPLICATION / PLAN.
- Issued Jul 10, 2025
New construction, addition, GFA change · For erection of an attach structure (Height not to exceed 35 feet) for use as single family household living. Size and location per plan.
Violations
1 entry
- Violation Jul 26, 2025OPEN
VACANT STRUCTURE & LAND
Track this owner
We'll flag their next deal, permit, or filing — usually before the neighbors know.
Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.