  1. Issued Jul 2, 2026

    7912-18 Bustleton Ave

    Addition and/or Alteration · Replace non working exit sign with new exit sign in kind

  2. Issued Jun 4, 2026

    1354 E Haines St

    Addition and/or Alteration · Rewire two unit duplex including lights, switches and receptacles, smoke and C/O detectors, 200 amp service and 3 gang meter bank

  3. Issued May 22, 2026

    3820 Linden Ave

    Addition and/or Alteration · Add 100 amp subpanel on second floor

  4. Issued May 19, 2026

    41 Montana St

    Addition and/or Alteration · 100 amp service including grounding, Exhaust fan ceiling (1) ground fault receptacle and dedicated circuit - first floor (1), Install bathroom fixture (2), install smoke detectors (2) install carbon/smoke detectors (1), new receptacle and circuit, arc fault, first floor(1) ALL WIRES FISHED IN WALLS AND CEILINGS

  5. Issued May 19, 2026

    3638 N 11th St

    Addition and/or Alteration · 100 amp service and 30 space panel (1), 3 way switch replacement (2), GFCI receptacle replacement (3) install smoke detectors (2) install carbon/smoke detectors (1), replace exterior light fixture (1), Add outdoor receptacle and light (1), replace receptacle (21) 15 A Afci circuit and receptacle bedroom (2) toggle switch replacement (11) Install flush mount basement lights (5) ALL WIRES FISHED IN WALLS AND CEILINGS

  6. Issued May 19, 2026

    1733 N Lambert St

    Addition and/or Alteration · 200 amp service, rewire existing home including lights, switches, receptacles, smoke/co detectors

  7. Issued May 14, 2026

    1525 W Chew Ave

    Addition and/or Alteration · Exhaust fan ceiling (1) ground fault receptacle and dedicated circuit - first floor (1), Install bathroom fixture (2), install smoke detectors (2) install carbon/smoke detectors (1), new receptacle and circuit, arc fault, first floor(1) ALL WIRES FISHED IN WALLS AND CEILINGS

  8. Issued May 4, 2026

    7019 Woolston Ave

    Addition and/or Alteration · Install a new 100-amp electrical service and one (1) 30-space panelboard, including service conductors, grounding, bonding, terminations, and circuit labeling. Replace two (2) three-way switches and eight (8) toggle switches. Install two (2) smoke detectors and one (1) combination smoke/carbon monoxide detector. Replace two (2) exterior light fixtures and two (2) additional exterior lights, as well as four (4) interior light fixtures. Replace twelve (12) receptacle outlets. Install three (

  9. Issued May 4, 2026

    4337 N 8th St

    Addition and/or Alteration · Install a new 100-amp electrical service and one (1) 30-space panelboard, including service conductors, grounding, bonding, terminations, and circuit identification. Replace two (2) three-way switches and eleven (11) toggle switches. Replace four (4) GFCI receptacles and seventeen (17) standard receptacle outlets. Install two (2) smoke detectors and one (1) combination smoke/carbon monoxide detector. Replace one (1) exterior light fixture and four (4) interior light fixtures. Install t

  10. Issued Apr 23, 2026

    2549 N Spangler St

    Addition and/or Alteration · Rewire 2 residential unit building including lights, switches, receptacles and smoke/co detectors per NEC code standards

  11. Issued Apr 20, 2026

    7304 Merganser Pl

    Addition and/or Alteration · Exhaust fan ceiling (1) ground fault receptacle and dedicated circuit - second floor (1), Install bathroom fixture (3), install smoke detectors (2) install carbon/smoke detectors (1), new receptacle and circuit, arc fault, second floor (1) ALL WIRES FISHED IN WALLS AND CEILINGS

  12. Issued Apr 19, 2026

    963 E Russell St

    Addition and/or Alteration · 100 amp panel and service with grounding, replace (4) lights switches, (14) receptacles, install (4) basement lights, (2)light switches, add 20 amp circuit and GFCI outlet in 2nd floor bathroom, add receptacle and circuit in Living room and Dining room, ALL WIRES FISHED IN WALLS AND CEILINGS

  13. Issued Mar 28, 2026

    4933 Boudinot St

    Addition and/or Alteration · 100 amp service and 30 space panel (1), 3 way switch replacement (2), Ground fault receptacle (1), install smoke detectors (2) install carbon/smoke detectors (1), replace exterior light fixture (1), replace interior light fixture (2), replace receptacle (11) 20 A Afci circuit and receptacle basement/first floor (1) switch replacement, toggle switch (11) install ungrounded receptacle (6) Repair junction box (1) Relocate bath GFCI, Install basement lights (3) Ground fault receptacle and dedicated

  14. Issued Mar 27, 2026

    909 Watkins St

    Addition and/or Alteration · Replace existing 100 amp service with new 200 amp service including meter socket, panel, breakers, grounding

  15. Issued Mar 27, 2026

    6322 Langdon St

    Addition and/or Alteration · Exhaust fan ceiling (1) ground fault receptacle and dedicated circuit - second floor (1), Install bathroom fixture (3), install smoke detectors (2) install carbon/smoke detectors (1), new receptacle and circuit, arc fault, second floor (1) wires fished in walls

  16. Issued Mar 27, 2026

    5011 Saul St

    Addition and/or Alteration · Dryer circuit 30 AMP (1) ground fault receptacle and dedicated circuit - second floor (1), Install bathroom fixture (3), install smoke detectors (2) install carbon/smoke detectors (1), new receptacle and circuit, arc fault, second floor (1) new receptacle and circuit, arc fault, basement/first floor (1) wires fished in walls

  17. Issued Mar 25, 2026

    6456 Ross St

    Addition and/or Alteration · 100 amp service and 30 space panel (1), 3 way switch replacement (4), Ground fault receptacle (2), install smoke detectors (2) install carbon/smoke detectors (1), replace exterior light fixture (1), replace interior light fixture (4), replace receptacle (13) 20 A Afci circuit and receptacle basement/first floor (1) switch replacement, toggle switch (10) install ungrounded receptacle (6)

  18. Issued Mar 25, 2026

    5318 Akron St

    Addition and/or Alteration · 30 space panel (1), Exhaust fan ceiling (1) ground fault receptacle and dedicated circuit - second floor (1), Install bathroom fixture (3), install smoke detectors (2) install carbon/smoke detectors (1), new receptacle and circuit, arc fault, second floor(1), relocate rear bed outlet and switch (1) all wires fished

  19. Issued Mar 25, 2026

    5500 Wyalusing Ave

    Addition and/or Alteration · 100 amp service and 30 space panel (1), 3 way switch replacement (2), Ground fault receptacle (3), flush mount basement ceiling light (3), install smoke detectors (2) install carbon/smoke detectors (1), replace exterior light fixture (2), replace interior light fixture (4), replace receptacle (14) 20 A Afci circuit and receptacle 2nd floor (1) switch replacement, toggle switch (6) all wires fished

  20. Issued Mar 24, 2026

    443 W Airdrie St

    Addition and/or Alteration · 100 amp service and 30 space panel (1), Electric wall/ceiling heater (1), Exhaust fan ceiling (1) ground fault receptacle and dedicated circuit - first floor (1), Install bathroom fixture (3), install smoke detectors (2) install carbon/smoke detectors (1), new receptacle and circuit, arc fault, basement (1), all wires fished

  21. Issued Mar 24, 2026

    2814 Mascher St

    Addition and/or Alteration · Exhaust fan ceiling (1) ground fault receptacle and dedicated circuit - first floor (1), Install bathroom fixture (3), install smoke detectors (2) install carbon/smoke detectors (1), new receptacle and circuit, arc fault, basement (1) Relocate electrical devices - Ceiling fan and outlet (1) all wires fished

  22. Issued Mar 3, 2026

    4048 Parkside Ave

    Addition and/or Alteration · rewire existing 6 unit building with new outlets, receptacles, lights, switches, smoke/co detectors, replace existing service with new 600 amp service and 7 gang meter bank. -NOTED :ALL LAUNDRY AREA RECEPTS TO BE W/I 6' (210.50 (C))

  23. Issued Mar 2, 2026

    3528 New Queen St

    Addition and/or Alteration · Install branch circuit wiring for the rear bathroom addition, including installation of lighting fixtures, switches, and receptacle outlets. . Receptacles shall be GFCI-protected as required. All work shall be performed in accordance with the 2017 NEC.

  24. Issued Jan 13, 2026

    4585 Fleming St

    Addition and/or Alteration · Rewire 2nd floor office, guest bedroom, master bedroom and bathroom including lights, receptacles and switches, install co/smoke detectors, add 60 amp subpanel. All wires will be fished inside walls and closed ceilings. as required by nec 2017

  25. Issued Dec 22, 2025

    2014 Tulip St

    Addition and/or Alteration · Replace existing 100 amp service with new 100 amp service, Complete rewire of row home including lights, switches, receptacles and co/smoke detectors

  26. Issued Aug 20, 2025

    391 Port Royal Ave

    New Construction · Electrical Permit for combo RP-2025-000368

Track this owner

We'll flag their next deal, permit, or filing — usually before the neighbors know.

Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.