THE INDEX: 64 17 · week of Jun 29permits soft, openings quiet, deal ledger quiet

The Philadelphia Index

Entity File · The Public Record

Contractor

George Williamson

10 permits

Records on file
10

Built (as contractor)

10 entries

  1. Issued May 18, 2026

    633 W Sedgwick St

    Addition and/or Alteration · Furnish, wire, and install new grounded romex wiring, grounded devices and AFCI protected circuits in place of the found knob and tube, old cloth wire and BX circuits found throughout the house as per the room list below. Wires will be fished through the walls. No demo or reconstruction of the walls will take place for this project. There is no other contractor apart of this project. - Front Porch. Includes 2nd light fixture location and (1) weather rated GFCI outlet - Living room - 1st Floo

  2. Issued May 18, 2026

    30 Benezet St

    Addition and/or Alteration · Remove the existing service equipment from the inside and the outside of the house. Furnish and install for (1) 200 amp over head service complete with the following qualifying items: - 200 Amp service cable drop (2) - 200 Amp weather rated service meter cabinet - 200 amp weather rated emergency disconnect switch - 40 circuit electrical panel with a 200 amp main lug panel - Circuit breakers as needed - Cold water and gas pipe bonding - (2) Ground rods and (1) grounding bridge bonding - Whole hou

  3. Issued Apr 13, 2026

    6323 Sherwood Rd

    Addition and/or Alteration · Updating electrical by fishing new romex wire in replace of old knob and tube wiring throughout the house. Remove the existing service equipment and replace with a new 200 amp service. Scope of work excludes existing HVAC system wiring.

  4. Issued Feb 25, 2026

    303 W Springfield Ave

    Addition and/or Alteration · AMEND PERMIT - Replace all the knob and tube wiring with romex (fishing wires only) for all the existing outlets, switching and lighting throughout the house. Remove the existing 100 amp service and replace with a 200 amp service. Excludes existing HVAC systems wiring. PROPER GROUNDING AND BONDING. REWIRE HOUSE THROUGHOUT AND INSTALL LIGHTING, SWITCHES AND RECEPTACLE OUTLETS. INSTALL 120 VOLTS INTERCONNECTED SMOKE AND CO ALARMS ACCORDING TO THE 2017 NEC. (FISHING WIRES ONLY)

  5. Issued Jan 12, 2026

    6334 Cherokee St

    Addition and/or Alteration · Remove the existing service equipment from the inside and the outside of the house. Furnish, wire, and install for (1) 200 amp overhead service complete with the following qualifying items: - 200 Amp service cable drop (2) - 200 Amp weather rated service meter cabinet - 200 amp weather rated emergency disconnect switch - 40 circuit electrical panel with a 200 amp main lug panel - Circuit breakers as needed - Cold water and gas pipe bonding - (2) Ground rods and (1) grounding bridge bonding - Who

  6. Issued Jan 6, 2026

    16 Benezet St

    Addition and/or Alteration · Updating electrical by fishing new romex wire in replace of old knob and tube wiring throughout the house. Remove the existing service equipment and replace with a new 100 amp service. There is no other constructor or renovation going on in this home besides upgrading the electrical system. Scope of work excludes existing HVAC system wiring.

  7. Issued Dec 8, 2025

    101 W Springfield Ave

    Addition and/or Alteration · Remove the existing service equipment from the inside and the outside of the house. Furnish, wire, and install for (1) 200 amp overhead service complete with the following qualifying items: - 200 Amp service cable drop (2) - 200 Amp weather rated service meter cabinet - 200 amp weather rated emergency disconnect switch - 40 circuit electrical panel with a 200 amp main lug panel - Circuit breakers as needed - Cold water and gas pipe bonding - (2) Ground rods and (1) grounding bridge bonding - Who

  8. Issued Dec 1, 2025

    7912 Winston Rd

    Addition and/or Alteration · Relocate the 200-amp electrical service, meter socket, and circuit breaker panel to a different area within the basement. Ensure all grounding and bonding are properly maintained in accordance with code. Extend the service cable and all associated branch-circuit wiring to the new circuit breaker panel location. ALL WORK TO BE BONE ACCORDING TO THE 2017 NEC.

  9. Issued Oct 8, 2025

    1147 N 4th St

    Addition and/or Alteration · Furnish and install necessary conduit and wire to power (31) EV charger stalls. Install (31) EV charges. - Install (6) new 60 amp, single phase, 208/240 volt circuits for the above line. - Provide commissioning for (31) EVC's - Furnish and install necessary conduit and wire for (2) WIFI AP locations. Installation shall comply with 2017 NEC

  10. Issued Aug 29, 2025

    500 W Moreland Ave

    Addition and/or Alteration · basement of the house as per the electrical drawings received and our qualifying items listed below. - Excavation and back fill from the proposed PECO pole to the back wall of the basement - Underground conduits and feeder lines from the proposed PECO pole to the into the back wall of the basement - New metering and a main 400 amp panel with circuit breakers - New feeder circuits from the 400 amp panel to the (4) remote sub panels. - Replace the original main panel with a new panel and circuit b

Track this owner

We'll flag their next deal, permit, or filing — usually before the neighbors know.

Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.
Last generated July 15, 2026.