8 permits
- Records on file
- 8
Permits (as owner)
8 entries
- Issued Jun 2, 2026
New Construction · COMBINED AUTOMATIC SPRINKLER & CLASS I MANUAL WET STANDPIPE SYSTEMS WITH SIX (6) INCH FIRE SERVICE LINE & BACKFLOW PREVENTION (BFP) ASSEMBLY TO SERVE PREVIOUSLY APPROVED MIXED-USE BUILDING. AUTOMATIC SPRINKLER SYSTEM & STANDPIPE SYSTME INSTALLATION PER NFPA 13/14. FIRE PUMP TO BE INSTALLED PER NFPA 20.
- Issued May 4, 2026
1 units
Addition and/or Alteration · FOR LEVEL II ALTERATIONS TO AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT 1ST AND 2ND FLOOR. FOR USE AS CHILD CARE-CHILD CARE CENTER AT 1ST AND 2ND FLOOR TO INCLUDE ACCESS TO ROOF DECK. ALL WORK TO BE DONE PER APPROVED PLANS. ***************** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ******************************************
- Issued Feb 19, 2026
Excavation · EXCAVATION WORK ASSOCIATED WITH NEW CONSTRUCTION BUILDING (SEE CP-2023-004665) TO INCLUDE SHEETING AND SHORING AND UNDERPINNING WORK AS PER APPROVED PLANS. UNDERPINNING TO BE MONITORED BY A PA LICENSED PE AT ALL TIMES. *2018 IBC REVIEW* **AMENDMENT APPROVED 3/26/26** AMEND EXCAVATION PERMIT SP-2024-001175 FOR CHANGES TO SHORING AND UNDERPINNING DESIGN AS PER APPROVED PLANS.
- Issued Nov 13, 2025
Major Demolition · MAKE-SAFE PERMIT: FOR THE COMPLETE DEMOLITION OF THE EXISTING ATTACHED STRUCTURE BY HAND AND MECHANICAL DEMOLITION TO RESOLVE CASE CF-2025-014944. ALL PERMITTED DEMOLITION ACTIVITY TO BE IN ACCORDANCE WITH APPROVED SITE SAFETY DEMOLITION PLAN & SUCH PLAN TO BE MAINTAINED ON SITE AT ALL TIMES IN ACCORDANCE WITH PHILADELPHIA ADMINISTRATIVE CODE. ANY DEVIATION WILL REQUIRE AN AMENDED BUILDING PERMIT. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. “A COVERED WALKWAY
- Issued Sep 24, 2025
Full Demolition · FOR THE COMPLETE DEMOLITION OF THE EXISTING ATTACHED STRUCTURE. SIZE AND LOCATION AS SHOWN IN THE APPLICATION / PLANS.
- Issued Sep 24, 2025
Alterations · SEAL LATERAL PA20251742434 REMOVE TRAP AND HERMETICALLY SEALING THE LATERAL BY A CAP OR PLUG ."ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"
- Issued Sep 24, 2025
Party Wall Protection · EZ Wall Protection Permit- Obtain permits for the application of exterior wall sidings for the purpose of finishing walls exposed during demolition (including party walls and independent bearing walls abutting party walls) without submitting plans by meeting the Conditions and Design Limitations below. Any deviations from this permit standard will result in permit revocation. PARTY WALL PROTECTION PERMIT FOR FINISHING EXTERIOR PARTY WALL AFTER DEMOLITION. *STUCCO* Property is classified as a n
Track this owner
We'll flag their next deal, permit, or filing — usually before the neighbors know.
Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.