Addition and/or Alteration · Remediation of Knob and Tube wiring as per NEC 2017; fishing wires
- Issued Apr 29, 2026
Addition and/or Alteration · Remediation of Knob and Tube wiring as per 2017 NEC; fishing wires
- Issued Apr 1, 2026
Addition and/or Alteration · Remediation of knob and tube wiring as per 2017 NEC; Fishing all wires
- Issued Mar 24, 2026
Addition and/or Alteration · 40 space distribution panel; Installing ground fault breaker (1), ground fault receptacles (8) and a hardwired smoke detector (1); Replacing 15 AMP receptacles (28), fixtures (9), 3-way switches (7) and toggle switches (10); Repairing wiring (1), outlet (1); Fishing wires -as per 2017 NEC
- Issued Mar 10, 2026
Addition and/or Alteration · 100 AMP service/30 space panel; Installing exhaust fan (1), dedicated circuit/ground fault receptacle (1), fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and an arc fault circuit/receptacle (1); Relocating electrical devices (2); Fishing wires -as per 2017 NEC
- Issued Mar 5, 2026
Addition and/or Alteration · Installing exhaust fan (1), dedicated circuit/ground fault receptacle (1), fixtures (3), 10 smoke detectors (2), 10 yr smoke/carbon combo (1) and an arc fault circuit/receptacle (1); Relocating electrical device (1); Fishing wires -as per 2017 NEC
- Issued Mar 4, 2026
Addition and/or Alteration · 30 space distribution panel; Installing exhaust fan (1), dedicated circuit/ground fault receptacle (1), fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and an arc fault circuit/receptacle (1); Fishing wires -as per 2017 NEC
- Issued Mar 2, 2026
Addition and/or Alteration · Install new 30-space electrical distribution panel. The panel will be properly grounded, bonded and provided with an updated and accurately identified circuit directory. The project includes the installation of one new dedicated branch circuit for an exhaust fan, one ground-fault circuit-interrupter (GFCI) protected receptacle, three new lighting fixtures, and one arc-fault circuit-interrupter (AFCI) protected circuit or receptacle. Additionally, two 10-year sealed battery smoke alarms and
- Issued Feb 26, 2026
Addition and/or Alteration · 30 space distribution panel; Installing exhaust fan (1), dedicated circuit/ground fault receptacle (1), fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and an arc fault circuit/receptacle (1); Fishing wires -as per 2017 NEC
- Issued Feb 26, 2026
Addition and/or Alteration · Installing exhaust fan (1), dedicated circuit/ground fault receptacle (1), fixtures (3), 10 yr smoke detector (2), 10 yr smoke/carbon combo (1) and an arc fault circuit/receptacle (1); Fishing wires -as per 2017 NEC
- Issued Feb 26, 2026
Addition and/or Alteration · Install one (1) exhaust fan. Provide one (1) dedicated circuit with ground-fault protection receptacle. Install three (3) light fixtures. Install two (2) 10-year sealed battery smoke detectors and one (1) 10-year sealed battery smoke/carbon monoxide combination detector. Provide one (1) arc-fault protected circuit/receptacle. All wiring to be fished within existing finished walls and ceilings. All work to be done according to the 2017 NEC.
- Issued Feb 24, 2026
Addition and/or Alteration · 100 AMP service/30 space panel; Fishing wires -as per 2017 NEC
- Issued Feb 23, 2026
Addition and/or Alteration · Installing wall heater (1), exhaust fan (1), dedicated circuit/ground fault receptacle (1), fixtures (2), 10 yr smoke detectors (2), 10 yr smoke/carbon combo and an arc fault circuit/receptacle (1); Fishing wires -as per 2017 NEC
- Issued Feb 11, 2026
Addition and/or Alteration · 30 space distribution panel; Installing exhaust fan (1), dedicated circuit/ground fault receptacle (1), fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and an arc fault circuit/receptacle (1); Fishing all wires -as per 2017 NEC
- Issued Feb 11, 2026
Addition and/or Alteration · Installing electric heater (1), exhaust fan (1), dedicated circuit/ground fault receptacle (1), fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1), and an arc fault circuit/receptacle (1); Relocating electrical device (1); Fishing all wires -as per 2017 NEC
- Issued Feb 10, 2026
Addition and/or Alteration · Installing 30 AMP dryer circuit (1), exhaust fan (1), dedicated circuit/ground fault receptacle (1), fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo and an arc fault circuit/receptacle (1); Fishing wires only -as per 2017 NEC
- Issued Feb 10, 2026
Addition and/or Alteration · Installing exhaust fan (1), dedicated circuit/ground fault receptacle (1), fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and an arc fault circuit/receptacle (1); Relocating electrical devices (2); Fishing all wires -as per 2017 NEC
- Issued Feb 9, 2026
Addition and/or Alteration · Installing exhaust fan (1), dedicated circuit/ground fault receptacle (1), fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and an arc fault circuit/receptacle (1); Fishing wires -as per 2017 NEC
- Issued Jan 30, 2026
Addition and/or Alteration · 100 AMP service/30 space panel, relocate panel; Installing 10 yr smoke/carbon combo, flush mount lights (3), 3-gang toggle plate (1), GFCIs (3), 20 AMP arc fault home run (1), 10 yr smoke detector (1), and junction boxes (2); Replacing single pole switches (7), 3-way switches (5), duplex receptacles (7) and LED ceiling fixtures (2); Fishing wires -as per 2017 NEC
- Issued Jan 30, 2026
Addition and/or Alteration · Installing exhaust fan (1), dedicated circuit/ground fault receptacle (1), fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and an arc fault circuit/receptacle (1); fishing wires -as per 2017 NEC
- Issued Jan 29, 2026
Addition and/or Alteration · 200 AMP service/40 space panel; Installing flush mount fixtures (4), 10 yr smoke/carbon combo (1), duplex receptacle (1), 20 AMP circuit/GFCI (5), 15 AMP arc home run/receptacle (1) and 10 yr smoke detectors (2); Replacing receptacle/resecure box (1), 3-way switches (2) and an existing outlet w/quad receptacle (1); Fishing wires -as per 2017 NEC
- Issued Jan 28, 2026
Addition and/or Alteration · 30 space distribution panel; Installing exhaust fan (1), dedicated circuit/ground fault receptacle (1); fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and an arc fault circuit/receptacle (1); Fishing wires -as per 2017 NEC
- Issued Jan 27, 2026
Addition and/or Alteration · 100 AMP service/30 space panel; Installing flush mount lights (3), GFCIs (4), 10 yr smoke/carbon combo (1), junction boxes (3), 20 AMP circuit/GFCI (1), 10 yr smoke detectors (2) and 15 AMP arc fault home run/receptacles (2); Replacing single pole switches (5), duplex receptacles (2), ceiling fixtures (3), 3-way switches (4), ungrounded receptacles (8), GFCI (1) and sconces (2); Fishing wires -as per 2017 NEC
- Issued Jan 27, 2026
Addition and/or Alteration · 30 space distribution panel; Installing exhaust fan, dedicated circuit/ground fault receptacle (1), fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1), arc fault circuit/receptacle (1) and an electric wall heater (1); Fishing wires -as 2017 NEC
- Issued Jan 27, 2026
Addition and/or Alteration · 100 AMP service/30 space panel; Installing flush mount fixtures (3), 10 yr smoke/carbon combo (1), GFCIs (5), 15 AMP arc fault home run/receptacles (2), 10 yr smoke detectors (2), junction boxes (2), wire mold boxes (2) and wire mold (15); Replacing duplex receptacles (18), single pole switches (4), 3-way switches (3), LED ceiling fixtures (4) and wire mold box w/deep wire mold box (1); Fishing wires -as per 2017 NEC
- Issued Jan 27, 2026
Addition and/or Alteration · Installing exhaust fan (1), dedicated circuit/ground fault receptacle (1), fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and an arc fault circuit/receptacle (1); Fishing wires -as per 2017 NEC
- Issued Jan 25, 2026
Addition and/or Alteration · Installing electric heater (1), dedicated circuit/ground fault receptacle (1), fixtures (2), smoke detectors (2), smoke/carbon combo (1) and an arc fault circuit/receptacle (1); Relocating thermostat (1); Fishing wires -as per 2017 NEC
- Issued Jan 25, 2026
Addition and/or Alteration · Installing exhaust fan (1), dedicated circuit/ground fault receptacle (1), fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and an arc fault circuit/receptacle (1); Fishing wires -as per 2017 NEC
- Issued Jan 20, 2026
Addition and/or Alteration · Installing electric wall heater (1), dedicated circuit/ground fault receptacle (1), fixtures (2), smoke detectors (2), smoke/carbon combo (1) and an arc fault circuit/receptacle (1); Relocating thermostat (1); Fishing wires -as per 2017 NEC
- Issued Jan 16, 2026
Addition and/or Alteration · Installing exhaust fan (1), dedicated circuit/ground fault receptacle (1), fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and an arc fault circuit/receptacle (1); Fishing wires -as per 2017 NEC
- Issued Jan 12, 2026
Addition and/or Alteration · Installing exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling fixtures (4), 10 yr smoke detectors (3), 10 yr smoke/carbon combo (1) and a 15 AMP arc fault home run (1); Relocating electrical devices (2); Fishing all wires -as per 2017 NEC
- Issued Jan 12, 2026
Addition and/or Alteration · Installing electric wall heater (1), 20 AMP circuit/GFCI (1), ceiling fixture (1), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 15 AMP arc fault home run (1); Relocating electrical devices (2); Fishing all wires -as per 2017 NEC
- Issued Jan 12, 2026
Addition and/or Alteration · Installing electric wall heater (1), ground fault receptacle/dedicated circuit (1), arc fault circuit/receptacle (1), fixtures (2), 10 yr smoke detectors (2) and a 10-yr smoke/carbon combo; Fishing wires -as per 2017 NEC
- Issued Jan 12, 2026
Addition and/or Alteration · Installing ceiling fixtures (3), 10 yr smoke detectors (2), 15 AMP arc fault home run (1), 10 yr smoke/carbon combo (1), 20 AMP circuit/GFCI (1) and an exhaust fan (1); Fishing all wires -as per 2017 NEC
- Issued Jan 12, 2026
Addition and/or Alteration · Installing exhaust fan (1), ground fault receptacle/dedicated circuit (1), fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and an arc fault/receptacle (1); Fishing wires -as per 2017 NEC
- Issued Jan 7, 2026
Addition and/or Alteration · Installing ceiling fixtures (2), 15 AMP arc fault home run (1), electric wall heater (1) and a 20 AMP arc fault home run; Fishing wires -as per 2017 NEC
- Issued Jan 7, 2026
Addition and/or Alteration · 30 space distribution; Installing exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 15 AMP arc fault home run; Relocating electrical device (1); Fishing wires -as per 2017 NEC
- Issued Jan 7, 2026
Addition and/or Alteration · 100 AMP service/30 space panel; Installing flush mount lights (3), 10 yr smoke detectors (3), GFCIs (2), 20 AMP circuit/GFCI (2), single pole switch (1) and 15 AMP arc fault home run/receptacles (3); Replacing single pole switches (8), ceiling fixture (1), duplex receptacles (4), 3-way switches (2), exterior LED fixture (1) and a sconce (1); Fishing wires -as per 2017 NEC
- Issued Jan 7, 2026
Addition and/or Alteration · Installing ceiling fixtures (3), 10 yr smoke detectors (2), 15 AMP arc fault home run (1), 10 yr smoke/carbon combo (1), 20 AMP circuit /GFCI (1), exhaust fan (1) and a 20 AMP duplex receptacle (1); Fishing wires -as per 2017 NEC
- Issued Jan 7, 2026
Addition and/or Alteration · 100 AMP service/30 space panel; Installing flush mount lights (3), 10 yr smoke/carbon combo (1), GFCIs (2), 20 AMP circuit/GFCI (2), 10 yr smoke detectors (2) and a 15 AMP arc fault home run/receptacle (1); Replacing single pole switches (7), duplex receptacles (10), 3-way switches (2) and LED ceiling fixtures (2); Repairing junction box (1); Fishing wires -as per 2017 NEC
- Issued Jan 7, 2026
Addition and/or Alteration · Installing electric wall heater (1), exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 15 AMP arc fault home run (1); Relocating electrical device (1); Fishing wires -as per 2017 NEC
- Issued Dec 30, 2025
Addition and/or Alteration · Fishing wires through walls per nec17 GFI circuit to 2nd floor bathroom install 2 new light 2nd floor bathroom install one 10year battary smoke detector install two 10 year battery smoke and carbon combo detectors
- Issued Dec 18, 2025
Addition and/or Alteration · 30 space distribution panel; Installing exhaust fan (1), 20 AMP circuit/GFCI (2), ceiling fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 15 AMP arc fault home run (1); Relocating electrical device (1); Fishing wires -as per 2017 NEC
- Issued Dec 4, 2025
Addition and/or Alteration · Installing exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 15 AMP arc fault home run (1); Relocating electrical device (1); Fishing wires
- Issued Nov 29, 2025
Addition and/or Alteration · Install 40 space distribution panel; Installing exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and 15 AMP arc fault home run (1) ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC. ( FISHING WIRE ONLY)
- Issued Nov 29, 2025
Addition and/or Alteration · Install 40 space distribution panel; Installing exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1), and a 15 AMP arc fault home run (1); Relocating electrical device (1) ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC. ********************************************(FISHING WIRES ONLY)************************************
- Issued Nov 19, 2025
Addition and/or Alteration · Installing exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and 15 AMP arc fault home run (1); Fishing wires -as per 2017 NEC
- Issued Nov 17, 2025
Addition and/or Alteration · 100 AMP service/30 space panel; Installing 30 AMP dryer circuit (1), flush mount lights (3), 10 yr smoke/ carbon combo (1), exterior fixture/motion sensor (1), GFCI (2), 10 yr smoke detector (2) and 15 AMP arc fault home run/receptacles (2); Replacing single pole switches (9), ceiling fixtures (4), duplex receptacles (13) and 3-way switches (4); Fishing wires -as per 2017 NEC
- Issued Nov 17, 2025
Addition and/or Alteration · 200 AMP service/40 space panel; Installing exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 15 AMP arc fault home run (1); Fishing wires -as per 2017 NEC
- Issued Nov 13, 2025
Addition and/or Alteration · Installing ceiling fixtures (3), 10 yr smoke /carbon combo (2), 15 AMP arc fault home run, 20 AMP circuit/GFCI (2) and an exhaust fan (1); Relocating electrical devices (2); Fishing wires -as per 2017 NEC
- Issued Nov 5, 2025
Addition and/or Alteration · Installing electric heater (1), exhaust fan (1), 20 AMP circuit/GFCI (2), ceiling fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 15 AMP arc fault home run (1); Fishing wires -as per 2017 NEC
- Issued Nov 5, 2025
Addition and/or Alteration · Installing electric heater (1), exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling lights (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 15 AMP arc fault home run; Fishing wires -as per 2017 NEC
- Issued Nov 4, 2025
Addition and/or Alteration · Installing exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling lights (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 15 AMP arc fault home run (1); Relocating electrical device (1); Fishing wires -as per 2017 NEC
- Issued Oct 31, 2025
Addition and/or Alteration · 40 space distribution panel; Installing exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 15 AMP arc fault home run (1); Relocating electrical devices (2); Fishing wires -as per 2017 NEC
- Issued Oct 31, 2025
Addition and/or Alteration · Installing exhaust fan (1), 20 AMP circuit/GFCI (2), ceiling fixtures (3), 10 yr smoke detector (1), 10 yr smoke/carbon combo (1) and a 15 AMP arc fault home run (1); Fishing wires -as per 2017 NEC
- Issued Oct 27, 2025
Addition and/or Alteration · Installing exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling lights (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 15 AMP arc fault home run (1); Relocating electrical device (1); Fishing wires -as per 2017 NEC
- Issued Oct 20, 2025
Addition and/or Alteration · Installing exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 15 AMP arc fault home run (1); Relocating electrical device (1); Fishing wires -as per 2017 NEC
- Issued Oct 15, 2025
Addition and/or Alteration · Installing 30 AMP circuit (1), exhaust fan (1), 20 AMP circuit/GFCI (2), ceiling fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 15 AMP arc fault home run (1); Fishing wires -as per 2017 NEC
- Issued Oct 7, 2025
Addition and/or Alteration · INSTALL 100 AMP ELECTRICAL SERVICE WITH MAIN CIRCUIT BREAKER PANEL AND PROPER GROUNDING AND BONDING. INSTALL WIRING, RECEPACLE OUTLETS, LIGHTING AND SWITCHES, WHERE REQUIRED THROUGHOUT HOUSE ACCORDING TO THE 2017 NEC AND THE SCOPE OF WORK IN THE EXECUTED CONTRACT. INSTALL SMOKE/CO ALARMS WITH 10 YRS ```BATTERY. **************** FISHING WIRES **********************
- Issued Oct 3, 2025
Addition and/or Alteration · INSTALL CEILING EXHAUST FAN AND BATHROOM LIGHT FIXTURE. INSTALL 20 AMP GFCI BRANCH CIRCUIT AND A 15 AMP AFCI BRANCH CIRCUIT. RELOCATED ELECTRICAL DEVICES. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC. ************ FISHING WIRE ONLY *************
- Issued Oct 1, 2025
Addition and/or Alteration · REPLACE CIRCUIT BREAKER PANEL. INSTALL CEILING EXHAUST FAN, LIGHTING, SWITCHES AND SMOKE DETECTOR WITH A 10 YRS. BATTERY BACKUP. INSTALL 20 AMP GFCI BRANCH CIRCUIT AND 15 AMP ARC FAULT BRANCH CIRCUIT. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC. *********************** FISHING WIRES ONLY*************************
- Issued Sep 24, 2025
Addition and/or Alteration · Installing exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling fixtures (3), 10 yr smoke detectors (2) and a 10 yr smoke/carbon combo; Fishing wires -as per 2017 NEC
- Issued Sep 22, 2025
Addition and/or Alteration · 100 AMP services/30 space panel; Installing flush mount lights (3), 10 yr smoke/carbon combo (1), exterior fixture w/motion sensor (1), GFCIs (2), 10 yr smoke detectors (2), 20 AMP arc fault home run/receptacle (1), single pole switch (1) and 15 AMP arc fault home run/receptacle (2); Replacing single pole switches (8), duplex receptacles (15), 3-way switches (2) and LED ceiling fixtures (2); Fishing wires -as per 2017 NEC
- Issued Sep 20, 2025
Addition and/or Alteration · Installing electric wall heater (1), exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling lights (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 15 AMP AFCI home run (1); Fishing wires -as per 2017 NEC
- Issued Sep 17, 2025
Addition and/or Alteration · 200 AMP service/40 space panel, support hanging wiring/provide junction boxes for cut ends; Installing flush mount lights (3), 10 yr smoke/carbon combo, GFCIs (9), LED retrofits (8) and 10 yr smoke detectors (2); Replacing single pole switches (10) and duplex receptacles (10); Fishing wires -as per 2017 NEC
- Issued Sep 15, 2025
Addition and/or Alteration · Installing exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling fixture (1), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 20 AMP arc fault home run; Relocating electrical device (1); Fishing wires -as per 2017 NEC
- Issued Sep 15, 2025
Addition and/or Alteration · 30 space panel replacement; Installing GFCI/outlet (2); fixture/motion sensor (1); LED retrofits (10), 10 yr smoke/carbon combo (1), GFCIs (3), 15 AMP arc fault home run (1), 15 AMP duplex receptacles (2), 10 yr smoke detectors (2), 20 AMP circuit/GFCI (1) and a 15 AMP arc fault home run/receptacle (1); Replacing duplex receptacles (14), single pole switch replacements (6), 3-way switches (4), LED wafer light (1); Fishing wires -as per 2017 NEC
- Issued Sep 11, 2025
Addition and/or Alteration · Installing electric heater (1), exhaust fan (1), 20 AMP circuit/GFCI (1), ground service, ceiling fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 15 AMP arc fault home run (1); Relocating electrical devices (2); Fishing wires -as per 2017 NEC
- Issued Sep 9, 2025
Addition and/or Alteration · Installing exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 15 AMP arc fault home run (1); Relocating electrical device (1); Fishing wires -as per 2017 NEC
- Issued Aug 29, 2025
Addition and/or Alteration · Replacing 40 space panel; Installing exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling fixtures (3), switch with motion sensor (1), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1), and a 15 AMP arc fault home run (1); Relocating electrical devices (2); Fishing wires -as per 2017 NEC
- Issued Aug 9, 2025
Addition and/or Alteration · 100 AMP service/30 space panel; Installing flush mount fixtures (3), 10 yr smoke/carbon combo (1), single pole switch (1), exterior fixture (1), GFCIs (8), 10 yr smoke detectors (2), LED retrofits (4) and a 15 AMP arc fault home run/receptacle (1); Replacing single pole switches (7), LED ceiling fixtures (6), duplex receptacles (12), 3-way switches (2) and vanity fixture (1); Fishing wires -as per 2017 NEC
- Issued Aug 9, 2025
Addition and/or Alteration · Installing electric wall/ceiling heater (1), exhaust fan (1), 20 AMP circuit/GFCI (1), ceiling fixtures (3), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 15 AMP arc fault home run (1); Fishing wires -as per 2017 NEC
- Issued Jul 30, 2025
Addition and/or Alteration · Installing ceiling fan, 20 AMP arc fault home run, 20 AMP circuit/GFCI (1), ceiling lights (2), wall fixtures (1), 10 yr smoke detectors (2) and a 10 yr smoke/carbon combo; Relocate electrical devices (2); Fishing wires -as per 2017 NEC
- Issued Jul 29, 2025
Addition and/or Alteration · 100 AMP service/30 space panel; Installing 20 AMP circuit/GFCI (1), exhaust fan (1), ceiling fixtures (2), wall fixture (1), 10 yr smoke detectors (2), 10 yr smoke/carbon combo (1) and a 20 AMP arc fault; Fishing wires -as per 2017 NEC
- Issued Jul 14, 2025
Addition and/or Alteration · 200 AMP service/40 space panel; Installing smoke/carbon combo (1), 15 AMP arc fault home run/outlet (3), GFCIs (3) and 10 yr smoke detectors (2); Replacing outdoor fixture, 3-way switches (5), duplex receptacles (13), motion flood light (1), single pole switches (9), ceiling fixtures (1) and a GFCI (1); Fishing wires -as per 2017 NEC
- Issued Jul 14, 2025
Addition and/or Alteration · Installing dryer circuit (1), 20 AMP circuit/GFCI (3), ceiling lights (3), exhaust fan (1), 10 yr smoke detectors (2), 10 yr smoke/carbon combo and a 20 AMP fault home run/receptacle (1); Relocating electrical device (1); Fishing wires -as per 2017 NEC
- Issued Jul 10, 2025
Addition and/or Alteration · 100 AMP Service/30 Space panel; Installing flush mount lights (2), drop light (1), 10 yr smoke detectors (3), LED retrofits (12) and GFCIs (4); Replacing single pole switches (13), GFCI (1), duplex receptacles (16), 3-way switches (2) and LED ceiling fixtures (3); Fishing wires -as per 2017 NEC
- Issued Jul 10, 2025
Addition and/or Alteration · 100 AMP Service/30 space panel; Installing 20 AMP circuit/GFCI, ceiling light (1), fixture/exhaust fan (1), wall fixture (1), 10 yr smoke detectors (2), 10 yr smoke/carbon combo and a 20 AMP arc fault home run (1); Relocate electrical device (1); Fishing wires- as per 2017 NEC
- Issued Jul 10, 2025
Addition and/or Alteration · 100 AMP service/30 space panel; Installing exterior fixture with motion detector (1), 10 yr smoke/carbon combo (1), LED ceiling lights (3), GFCIs (6), 1900 Box for GFCI (1), LED retrofits (10) and 10 yr smoke detector (2); Replacing single pole switches (10), duplex receptacles (7), 3-way switches (3), receptacle/box (1) and exterior LED sconce; Fishing wires -as per 2017 NEC
Track this owner
We'll flag their next deal, permit, or filing — usually before the neighbors know.
Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.