- Issued Jun 24, 2026
Addition and/or Alteration · Remove existing chiller-1, VFD, and pump. Install new chiller-1, VFDs, and pumps utilizing existing feeders as per approved sealed electrical drawings, single line. Install a new 480V 3-phase 4-wire 225A Panel CH as per single line. MP-2026-002665
- Issued Jun 16, 2026
Addition and/or Alteration · PER The Historical Commission: No exterior work permitted as part of this permit. Install new light fixtures, lighting controls, and receptacles. Install (3) new motor starters for exhaust fans. ALL WORK PER APPROVED PLANS ***NO FIRE ALARM ON THIS PERMIT**
- Issued May 7, 2026
Addition and/or Alteration · Remove existing boiler, water heater, pump and disconnect circuits as per sealed electrical drawings. Install new circuits to 3 new water heaters. install new 120/208V 100A MLO panel BP. New feeder from existing 120/208V 100A 3P 4W panel A as per attached sealed electrical drawing and 2017 NEC.
- Issued Apr 2, 2026
Rough-In · Rough-In Permit for EP-2026-002816 Install new light fixtures, lighting controls, receptacles, fire alarm, nurse call devices, tele/data cabling, HVAC power wiring and electrical distribution as per attached sealed electrical drawings. All tele/data cabling to be plenum rated less than 200' linear foot. Fire Alarm sealed drawings will be uploaded when received from engineer.
- Issued Mar 31, 2026
Addition and/or Alteration · All Circuits are Existing to Relocate. Demo 3 fixtures and 2 receptacles. Install 3 downlights, 2 2x4 LED fixtures, 1 wall occupancy sensor, relocate 9 floor boxed for power, relocate 13 wall furniture feeds for power, relocate 35 wall furniture feeds for date, relocate 4 receptacles and 4 date drops. All circuits are existing to relocate. All work Per approved plans NEC 2017 ***Interior only, non-historic building. No Fire alarm. Work on this permit.***
- Issued Feb 19, 2026
Addition and/or Alteration · Install new light fixtures, HVAC power wiring, new 208/120V 600A 3Ph 4W MDP, new 100KVA NEMA-1 208V:240V/120 IPH XFMR as per 2017 NEC. Primary service by PECO. We are provide (2) 5" conduits for PECO and installing PECO provided meter.
- Issued Jan 8, 2026
Addition and/or Alteration · Install power wiring to replace existing rooftop chiller. Install new feeders, disconnects, heat trace, new 120/208V 800A 3P 4W Panel HCP as per attached sealed electrical drawings. Mechanical Permit # is MP-2025-004908.
- Issued Dec 22, 2025
Addition and/or Alteration · Electrical Permit for combo CP-2025-004304
- Issued Dec 15, 2025
Addition and/or Alteration · Install new light fixtures, lighting controls, receptacles, tele/data raceways, HVAC power wiring. All work to be done according to the 2017 NEC and per approved plans, (FIRE ALARM SYSTEM IS NOT INCLUDED IN THE SCOPE OF WORK) Amendment: Install fire alarm system. All work to be done according to the 2017 NEC, 2016 NFPA 72 and per approved plans.
- Issued Dec 8, 2025
Addition and/or Alteration · Install new light fixtures, receptacles, HVAC power wiring, and tele/data raceways as per 2017 NEC. Install fire alarm as per 2016 NFPA 72.
- Issued Nov 26, 2025
Addition and/or Alteration · Install new light fixtures, lighting controls, utilizing existing circuits. Install (1) new 150A 3P 480V Circuit for new sterilizer feed from existing Panel ERP-6-1. Extend existing branch circuits to feed two sterilizers. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC AND PER PLANS.
- Issued Nov 24, 2025
Addition and/or Alteration · Remove existing electrical service and install new service as per attached sealed single line drawings. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC AND PER PLANS.
- Issued Nov 24, 2025
Addition and/or Alteration · Install new light fixtures, lighting controls, receptacles, HVAC power wiring as per 2017 NEC. Electrical service is existing. Install fire alarm system as per 2016 NFPA 72. Fire alarm devices in corridors are existing and are not included in the fire alarm scope of work.
- Issued Oct 30, 2025
Addition and/or Alteration · Demo receptacles. Install new receptacles utilizing existing circuits and panels as per attached sealed electrical drawings. Install tele/data raceways AS PER 2017 NEC. Install 2 new fire alarm devices as per 2016 NFPA 72.
- Issued Oct 23, 2025
Addition and/or Alteration · Electrical Permit for combo CP-2025-005351
- Issued Sep 17, 2025
Addition and/or Alteration · REWIRE HOUSE THROUGHOUT AND INSTALL LIGHTING, SWITCHES AND RECEPTACLE OUTLETS. INSTALL INTERCONNECTED SMOKE AND CO ALARMS ACCORDING TO THE 2017 NEC.
- Issued Sep 15, 2025
New Construction · The installation of vehicular kiosk/gates and lighting at the southwest and northwest lots of the Philadelphia Art Museum. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC.
- Issued Sep 15, 2025
Addition and/or Alteration · Electrical Permit for combo CP-2025-003358
- Issued Jul 30, 2025
Addition and/or Alteration · INSTALL WIRING, LIGHTING, LIGHTING CONTROLS, EMERGENCY LIGHTING AND RECEPTACLE OUTLETS. INSTALL TELE/DATA RACEWAYS USING EXISTING CIRCUITS. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC AND PER PLANS.
- Issued Jul 16, 2025
Addition and/or Alteration · Remove (86) existing fluorescent warehouse fixtures and replace with (86) New LED high bay light fixtures in existing location.
- Issued Jul 16, 2025
Addition and/or Alteration · Install additional fire alarm notification devices in Suites 100, 200 and 300 to bring building fire alarm system up to current code. Suite 100 - (22 horn strobes and 18 strobes). Suite 200 - (34 horn strobe and 16 strobes) Suite 300 - (9 horn strobes and 3 strobes) . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72.
Track this owner
We'll flag their next deal, permit, or filing — usually before the neighbors know.
Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.