Entity File · The Public Record
Contractor
Michael Villa
10 permits
- Records on file
- 10
Built (as contractor)
10 entries
- Issued Jun 16, 2026
Addition and/or Alteration · one 20 amp bathroom circuit to 2nd floor (fishing) one 15 amp afci circuit to master bedroom, 3 receptacles, light switch, wire to light (fishing) one 15 amp afci circuit for middle and back bedroom, 2 receptacles and 1 light switch each room (fishing) one 15 amp circuit for fridge (fishing) basement lighting circuit with 4 lights (unfinished space)
- Issued Jun 11, 2026
Addition and/or Alteration · 15 amp dedicated circuit. drill hole through basement and route wiring on outside of home to 2nd floor for a receptacle
- Issued Jun 1, 2026
Addition and/or Alteration · AMEND 06-30-2026 Adding low voltage under cabinet lighting, fishing wire. Adding dimmer switch for low volt lighting, fishing wire. Extending a 20 amp kitchen circuit for a future microwave, also adding required AFCI/GFCI protection, installing 20 amp receptacle (fishing the wall)
- Issued Apr 7, 2026
Addition and/or Alteration · 15 amp afci lighting circuit in unfinished basement. pulling 14-2 cable through joists. Install of light switch
- Issued Mar 25, 2026
Addition and/or Alteration · Replacing and relocating 100 amp panel in basement 10 ft from current location. Install new seu cable from load side of meter to new panel location. Install junction box at current panel location and extend existing circuits to new panel location through ceiling joists in unfinished basement no fishing required. Grounding electrode at water meter and 2 ground rods >>>BASEMENT TO REMAIN UNINHABITABLE<<<
- Issued Mar 4, 2026
Addition and/or Alteration · INSTALL 200 AMP ELECTRICAL SERVICE, METER SOCKET AND CIRCUIT BREAKER PANEL WITH PROPER GROUNDING AND BONDING. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC.
- Issued Feb 5, 2026
Addition and/or Alteration · AMEND 02/05/2026 Fishing 20 amp circuit to bathroom with gfci fishing 15 amp circuit to living room fishing 15 amp circuit to bedroom fishing wire to light for all 3 bedrooms and bathroom New 20 amp circuit to washer and dryer (unfinished basement) new 15 amp circuit for fridge old work new range hood circuit old work new 15 amp circuit for 2 bedroom old work 3 receptacles each (wiremold)
- Issued Jan 20, 2026
Addition and/or Alteration · 100 to 200 amp service upgrade. install outdoor 200 amp meter main breaker, new seu riser, ser load cable from meter to panel 200 amp panel, and required grounding electrodes.
- Issued Dec 19, 2025
Addition and/or Alteration · Replacing 100 amp panel due to corrosion. Replacing 100 amp load cable from meter to electrical panel.
- Issued Sep 15, 2025
Addition and/or Alteration · Installing new 60 amp subpanel in the detached garage. Will drill through wall and install 3/4 pvc conduit under pavers and into garage will also be installing 2 new light fixtures and 2 20 amp gfci circuits
Track this owner
We'll flag their next deal, permit, or filing — usually before the neighbors know.
Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.