- Issued Jul 8, 2026
Addition and/or Alteration · Install 15 light thru mean of fishing in the first floor only as per 2020 nec Replace all outlet and switches in kind
- Issued Jun 26, 2026
Addition and/or Alteration · Rewire as per Nec 2017 2. Smokes and Co detector 3. 20 recess lights 4. Install arch faults as per nec 2017 5. Replace complete 100 amp service
- Issued Jun 25, 2026
Addition and/or Alteration · Amend Permit 6/30/2026 - The electrical work includes interior wiring for the approved residential renovation scope at 423 S 20th St, Philadelphia, PA 19146, including lighting, switches, receptacles, kitchen/bathroom wiring, HVAC-related electrical connections, appliance circuits, GFCI/AFCI protection as required, and related branch circuit modifications. Electrical Permit for combo RP-2026-005543
- Issued Jun 22, 2026
Addition and/or Alteration · Install 15 recess thru means of fishing in first floor. Replace all outlets and switches in kind. Replace 100 amp panel in kind All work to to be performed according to the 2017 NEC and per executed contract.
- Issued Jun 17, 2026
Addition and/or Alteration · Electrical Permit for combo RP-2026-003525
- Issued Jun 12, 2026
Addition and/or Alteration · Rewire as per Nec 2017 Smokes and Co detector 20 recess lights Install arch faults as per nec 2017 Replace 100amp panel inkind.
- Issued Jun 4, 2026
Addition and/or Alteration · Replace all light fixture in kind Replace all switches and outlets Install 12 recess light using existing circuit
- Issued May 28, 2026
Addition and/or Alteration · Replace all light fixture in kind Replace all switches and outlets Install 12 recess light using existing circuit in the first floor only
- Issued May 27, 2026
Addition and/or Alteration · Install 25 recess light thru means of fishing as per NEC 2017 Install GFCI for two bathrooms thru means of fishing Replace all outlets and switches inkind Rewire kitchen as per new layout thru means of fishing Replace rusted out 100 panel
- Issued May 27, 2026
Addition and/or Alteration · Rewire the dwelling throughout, including installation of new branch circuit wiring, lighting fixtures, switches, and receptacle outlets. Provide dedicated branch circuits for appliances as required. Install 120-volt interconnected smoke and carbon monoxide alarms. All work shall be performed in accordance with the 2017 NEC and per approved plans.
- Issued May 21, 2026
Addition and/or Alteration · Rewire as per Nec 2017 Smokes and Co detector 20 recess lights Install arch faults as per nec 2017 Replace 100 amp panel in kind.
- Issued May 8, 2026
Addition and/or Alteration · Rewire as per Nec 2017 Smokes and Co detector 20 recess lights Install arch faults as per nec 2017 Replace 100amp panel in kind.
- Issued May 5, 2026
Addition and/or Alteration · Rewire single family as per nec 2017 20- recess light Replace 100 amp panel in kind. Arch fault where needed Smokes and Co detector
- Issued May 4, 2026
Addition and/or Alteration · Install twenty-five (25) recessed light fixtures. Install GFCI-protected receptacles for two (2) bathrooms. Replace all existing outlets and switches in-kind throughout the dwelling. Rewire the kitchen in accordance with the new layout, including installation of required branch circuits, receptacles, switches, and lighting as shown on the updated plan. Replace the existing rusted 100-amp panel with a new panelboard, including proper grounding, bonding, overcurrent protection, and circuit
- Issued Apr 27, 2026
Addition and/or Alteration · Replace rusted out 100 amp meter socket in kind
- Issued Apr 16, 2026
Addition and/or Alteration · Rewire as per Nec 2017 Smokes and Co detector 20 recess lights Install arch faults as per nec 2017 Replace 100 amp panel in kind
- Issued Apr 16, 2026
Addition and/or Alteration · Rewire as per Nec 2017 Smokes and Co detector 20 recess light Install arch faults as per nec 2017 Replace 100amp panel inkind
- Issued Apr 15, 2026
Addition and/or Alteration · 1. Replace old 400 amp and Install complete 400 amp service - 5 gang meter bank in kind 2. 150 amp per position on 1st, 3rd, and 2nd floor units 3. 200 amp on house panel 4. Rewire each unit throughout 5. Smoke and co alarms 6. 20 recess light per unit 7. Arc fault and GFCI as per 2017 NEC 8. Complete Fire alarm system as per plans and 2016 NFPA 72
- Issued Apr 14, 2026
Addition and/or Alteration · Complete Rewire as per nec 2017 20 recess light Smoke and CO as needed Replace 100amp in kind Arc fault breakers where needed
- Issued Apr 8, 2026
Addition and/or Alteration · Complete Rewire by means for fishing as per nec 2017 Fish 20 recess lights Smoke and co as needed Service was upgraded to a complete 200 amp service
- Issued Apr 2, 2026
Addition and/or Alteration · Electrical Permit for combo RP-2025-008331
- Issued Mar 30, 2026
Addition and/or Alteration · Upgrade to 125 panel, and rewire, existing single family dwelling led lighting,
- Issued Mar 27, 2026
Addition and/or Alteration · Electrical Permit for combo RP-2025-013157
- Issued Mar 24, 2026
Addition and/or Alteration · Replace all light fixture in kind Replace all switches and outlets Install 6 recessed light using existing circuit
- Issued Mar 2, 2026
Addition and/or Alteration · Complete Rewire through out as per NEC 2017 20 recess light Smoke and CO detector Arch fault panel Replace 100 amp panel in kind
- Issued Feb 27, 2026
Addition and/or Alteration · Rewire single family through out as 2017 Install 20 recess lights Smokes and co detectors Arch faults as per nec 2017
- Issued Feb 24, 2026
Addition and/or Alteration · Restoration of the electrical system to its original condition following prior damage. Work includes the replacement of electrical wiring, lighting fixtures, and devices (receptacles/switches) 110v interconnected smoke alarms . All work will maintain the original design and configuration with no modifications to the existing layout or structure From existing 200A service. -2017 NEC.
- Issued Feb 11, 2026
Addition and/or Alteration · Wire up one new bedroom addition using existing circuit as per nec 2017 One smoke 4 recessed light
- Issued Feb 9, 2026
Addition and/or Alteration · Add additional receptacles and lighting to existing service in the addition
- Issued Jan 20, 2026
Addition and/or Alteration · Rewire a bathroom and 2 bedroom to meet new layout per nec 2017 Add 2 smoke for the bedroom as per code 2017 Add 10 recess light
- Issued Jan 14, 2026
Addition and/or Alteration · Rewire thru out as per NEC 2017 20 recess lights Smoke and Co Detector Arch fault breakers
- Issued Jan 6, 2026
Addition and/or Alteration · Install a complete 200 amp service Rewire thru out as per NEC 2017 Install 20 recess lights Smoke and Co detectors 5. Install arch faults as per Nec 2017
- Issued Dec 29, 2025
Addition and/or Alteration · Electrical Permit for combo RP-2025-009167
- Issued Dec 29, 2025
Addition and/or Alteration · -Rewire as per NEC 2017 TO EXISTING BUILDING TO COMBINE EXISTING DWELLING UNITS TO CREATE A NEW TOTAL OF FOUR (4) DWELLING UNITS IN THE BUILDING-20 recess lights -Smoke detectors
- Issued Dec 16, 2025
Addition and/or Alteration · AMEND 04242026 100 amp service Complete Rewire as 2017 nec code box 20 recess lights Smoke and co detector Arc faults as per nec 2017
- Issued Dec 16, 2025
Addition and/or Alteration · Replace all outlets and switches in kind Install 14 lights in the first floor thru means of fishing using existing circuit as per nec 2017
- Issued Dec 16, 2025
Addition and/or Alteration · Install light in the first floor using existing circuit and by means of fishing as per nec 2017 Replace all outlets and switches in kind
- Issued Dec 4, 2025
Addition and/or Alteration · Rewire as per Nec 2017 Smokes and Co detector 20 recess lights Install arch faults as per nec 2017 Replace 100amp panel in kind
- Issued Dec 4, 2025
Addition and/or Alteration · Complete Rewire as per Nec 2017 code Smokes and Co detectors 20 recess lights Smoke Arch faults breaker as per Nec 2017
- Issued Nov 27, 2025
Addition and/or Alteration · REWIRE BATHROOM AND KITCHEN. INSTALL LIGHTING, SWITCHES AND RECEPTACLE OUTLETS. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC AND PER EXECUTED CONTRACT.
- Issued Nov 27, 2025
Addition and/or Alteration · INSTALL 200 AMP ELECTRICAL SERVICE, METER SOCKET AND CIRCUIT BREAKER PANEL WITH PROPER GROUNDING AND BONDING. REWIRE HOUSE THROUGHOUT AND INSTALL LIGHTING, SWITCHES AND RECEPTACLE OUTLETS. INSTALL 120 VOLTS INTERCONNECTED SMOKE AND CO ALARMS ACCORDING TO THE 2017 NEC.
- Issued Nov 19, 2025
Addition and/or Alteration · 1. Wiring up new edition on 3rd floor as per nec 2017 2. Add smoke and co detector 3. 10 recessed lights 4. 1 gfci for bathroom
- Issued Nov 19, 2025
Addition and/or Alteration · 1. Install 10 recess light in the first floor using existing wiring as per Nec 2017 2. Replace all outlets and switches in kind (no new wiring)
- Issued Nov 12, 2025
Addition and/or Alteration · 1. Rewire as per Nec 2017 2. Smokes and Co detector 3. 20 recess lights 4. Install arch faults as per nec 2017 5. Replace 100amp panel inkind.
- Issued Nov 3, 2025
Addition and/or Alteration · PARENT BUILDING PERMIT FOR SIGNAGE #GP-2025-008509 Wiring for new accessory wall sign with static illumination. 120V power supplied through wall at interior junction box. E14 bulbs rated for wet condition over entire face of sign. Sockets installed through sign face wired behind in four (4) channels.
- Issued Oct 27, 2025
Addition and/or Alteration · Rewire kitchen to fit new layout as per nec 2017 Install 35 recess lights throughout as per code Replacing all outlets and switches Install hardwired smoke detectors By means of fishing.
- Issued Oct 14, 2025
Addition and/or Alteration · 1. Install 15 6” recess light on first floor 2. Add one 220v circuit to kitchen for new stove 3. Add 4 recess light in master bedroom
- Issued Oct 10, 2025
Addition and/or Alteration · 1. Rewire as per Nec 2017 2. Smokes and Co detector 3. 20 recess lights 4. Install arch faults as per nec 2017 5. Replace 100amp panel in kind.
- Issued Oct 10, 2025
Addition and/or Alteration · Renew 1 - 100 AMP panel, 1-meter socket with disconnect, new switches and receptacles. throughout in existing boxes, replace ceiling mounted lighting with LED high hat lighting as per 2017 NEC
- Issued Oct 9, 2025
Addition and/or Alteration · 1. Replace 100 panel in kind 2. Rewire thru at as per 2017 nec code 3. Smoke and co detector 4. 20 recess light 5. Arch fault and gfci as per nec 2017
- Issued Sep 17, 2025
Addition and/or Alteration · Rewire as per Nec 2017 Smokes and Co detector 20 recess light Replace 100 amp inkind Install arch faults as per nec 2017
- Issued Sep 16, 2025
Addition and/or Alteration · Install 10 recess light using existing circuit as per Nec 2017 Replace all outlets and switches in kind.
- Issued Aug 27, 2025
Addition and/or Alteration · INSTALL TWO 100 AMP CIRCUIT BREAKER PANELS, 2 METER SOCKETS WITH PROPER GROUNDING AND BONDING. INSTALL WIRING, LIGHTING, SWITCHES AND RECEPTACLE OUTLETS. INSTALL SMOKE/CO ALARMS WITH BATTERY BACKUP ACCORDING TO THE 2017 NEC.
- Issued Aug 2, 2025
Addition and/or Alteration · Wiring up new addition as percent 2017 4 recess lights 1gfci
- Issued Jul 31, 2025
Addition and/or Alteration · Replacing GFI’s and electrical sockets throughout, Wiring replacement for switches & smoke detectors, Replacement of fixtures and installation of highhats, 200 Amp Service installation
- Issued Jul 31, 2025
Addition and/or Alteration · Rewire as per Nec 2017 Smokes and Co detector 20 recess lights Install arch faults as per nec 2017 Replace 100amp panel inkind.
- Issued Jul 31, 2025
Addition and/or Alteration · For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 sh
- Issued Jul 22, 2025
Addition and/or Alteration · Electrical Permit for combo RP-2025-006666
- Issued Jul 17, 2025
Addition and/or Alteration · Rewire as per Nec 2017 Smokes and Co detector 20 recess lights Install arch faults as per nec 2017 Replace 100 amp panel in kind
Track this owner
We'll flag their next deal, permit, or filing — usually before the neighbors know.
Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.