Entity File · The Public Record
Owner of record
Pennsylvania Ballet Assoc
7 permits
- Records on file
- 7
Permits (as owner)
7 entries
- Issued May 8, 2026
Addition and/or Alteration · Install AV equipment including projectors, monitors, cameras, movie screen, speakers input plates for video and audio in studios and classrooms.
- Issued Mar 11, 2026
Addition and/or Alteration · Install security equipment as per scope. 1 camera station, 19 card readers 19 door controllers, 4 network switches, 29 mini dome cameras, main pc for camera and security control, pull cat 6 wire to each location, door control wire for card access.
- Issued Feb 2, 2026
Addition and/or Alteration · Provide and install fire alarm system as per 2016 NFPA 72.
- Issued Oct 29, 2025
Signs (Accessory / Non-Accessory) · FOR THE ERECTION OF SIX (6) SIGNS; (TWO (2) SIGNS ‘LDS-1’: DIGITAL DISPLAY SIGNS: 72.63 SF (WOOD ST) & 201.74 SF (N BROAD ST); (TWO (2) SIGNS: ‘SC-1’: STATICALLY ILLUMINATED FLAT-WALL SIGNS: 6.04 SF (WOOD ST) & 11.3 SF (N BROAD ST); (ONE (1) SIGN ‘SC-2’: STATICALLY ILLUMINATED FLAT-WALL SIGNS (1.45 SF (WOOD ST); (ONE (1) SIGN: STATICALLY ILLUMINATED FLAT-WALL SIGN: 4.96 SF); ACCESSORY TO A BALLET FACILITY WITH PERFORMING ARTS, EVENT SPACE, EDUCATIONAL SPACE, WITH ALL OTHER SIGNS AS PREVIOUSLY AP
- Issued Sep 5, 2025
New Construction or Additions · NEW CONSTRUCTION OF ADDDITION CONNECTING TO EXISTING BUILDING. SANITARY SYSTEM TO HAVE NEW CURB TRAP AND FAI CONNECTIONS UNDER EXTERIOR PERMIT #PP-2024-013249. BACKFLOW PREVENTER IS EXISTING AS SPECIFEID IN PLANS. VENTING TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE BASE CODE. INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR LISTED FIXTURES. ALL MATERIALS UTILIZED IN THIS PROJECT TO BE METALLIC. ALL WORK TO BE PERFORMED IN STRICT COMPLIANCE WITH 2018 PPC AND APPROVED PLANS. ANY
- Issued Aug 28, 2025
New Construction · FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.
- Issued Jul 16, 2025
Addition and/or Alteration · Install new service (1200A MDP , 1000A MDP)lighting, lighting control, switch-gear. Provide and install theatrical lighting. Provide conduits and raceways for low voltage system. Install generator and ATS SWITCHES . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE. AMENDMENT: No amendment req'd as generator install was engineer designed/approved ,rescue assistance system & fire alarm were on a separate permit**
Track this owner
We'll flag their next deal, permit, or filing — usually before the neighbors know.
Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.