  1. Issued Jun 22, 2026

    6942 Cedar Park Ave

    Addition and/or Alteration · 100 amps service, replace 2 3 way switches, 20am ARC fault panel, replace 3 GFCI receptacle, 1 GFCI bathroom, install 3 LED fixtures basement, 4 redistribute circuit's, 19 receptacle, 13 switches replacement. (All wires are fished as per 2017 nec)

  2. Issued Jun 12, 2026

    1224 Fanshawe St

    Addition and/or Alteration · replace 2 -3way switches, 2 arc fault breakers, Distributio panel, 4 GFCI in kitchen , 2 GFCI basement, 4 -3 ways swithes basement & hallway.4 LED light fixtures basement,2 redistribute circuit basement, 10 receptacle replacement, 17 swithes replacement. (All wires are fished as per 2017 nec )

  3. Issued Jun 1, 2026

    1411 N 19th St

    Addition and/or Alteration · Distribution panel, 6 -3 way switches replacement, 17 switches replacement, 18 receptacle replacement, 4 LED fixtures replacement bedroom & basement, 5 Gfci kitchen and bathroom 2 redistribution in basement. (All wires are fished as per 2017 nec )

  4. Issued May 26, 2026

    148 N 53rd St

    Addition and/or Alteration · 100 amp service, replace 2 -3way switches, 4 GFCI kitchen & bathroom, 4 led lights fixtures one kitchen, 3 basement. 4 redistribution circuit basement.9 switches replacement, 15 receptacle replacement. ( All wires are fished as per 2017 nec )

  5. Issued Apr 17, 2026

    3918 Reno St

    Addition and/or Alteration · 100amps service, replace 2-3 ways switches, 2 Arc fault20 amp breakers,2 GFCI basement,2 GFCI kitchen, one GFCI bathroom,15 replacement receptacle, 10 switches replacement.( All wires are fished as per 2017 nec )

  6. Issued Apr 17, 2026

    5944 N Park Ave

    Addition and/or Alteration · 100amps service, replace 2-3 ways switches ,3 GFCI bathroom washer, kitchen, 4 LED basement, bedroom, exterior light replacement, 3 light basement, 12 switches replacement( All wires are fished as per 2017 nec )

  7. Issued Apr 9, 2026

    1939 Dudley St

    Addition and/or Alteration · 100 amps service, replace 2-3 way switches, 2 ARC fault 20 amp , 2 GFCI washer & dryer, 1 GFCI bathroom, 5 LED light, 10 receptacle replacement, 14 switches replacement, (All wires are fished as per 2017 nec )

  8. Issued Apr 9, 2026

    536 Overlook Rd

    Addition and/or Alteration · Replace 4-3 way switches, Distribution panel, 1 GFCI replacement, 2 GFCI basement & kitchen,1 GFIC replacement bathroom, Ground service, 1 GFCI outside, 1 LED light fixture basement. 22 receptacle replacement, 18 switches replacement (All wires are fished as per 2017 nec)

  9. Issued Mar 13, 2026

    221 Rosemar St

    Addition and/or Alteration · 100amps service, 2-3 ways switches replacement,1 ARC fault 20amps,1 dryer circuit 30amp,3 GFCI replacement,1GFCI washer, ! GFCI bathroom, 2 ARC fault bedroom, 10 redistribute basement,3led light fixtures basement,12 receptacle replacement,10 switches replacement.( ALL wires are fished as per 2017 nec)

  10. Issued Mar 2, 2026

    410 W Wellens St

    Addition and/or Alteration · INSTALL 100 AMP ELECTRICAL SERVICE AND MAIN CIRCUIT BREAKER PANEL WITH PROPER GROUNDING AND BONDING. INSTALL WIRING, RECEPACLE OUTLETS, LIGHTING AND SWITCHES, WHERE REQUIRED THROUGHOUT HOUSE. INSTALL SMOKE/CO ALARMS WITH 10 YRS BATTERY BACKUP. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC AND THE SCOPE OF WORK IN THE EXECUTED CONTRACT. (Fishing Wires)

  11. Issued Feb 2, 2026

    3304 Germantown Ave

    Addition and/or Alteration · Install 300 am service with grounding. Install lighting, receptacles, (1) 200 MCB amp panel, (1) 125 MCB amp panel, (1) 100 amp MCB panel, and provide power to equipment as per 2017 NEC. Install fire alarm as per 2016 NFPA 72.

  12. Issued Jan 25, 2026

    9965 Woodfern Rd

    Addition and/or Alteration · 100amps service, replace2-3 ways swithes, 4 GFCI 2 kitchen, bathroom & washer, one LED light fixtures hall .2 redisteibute , 17 receptacle replacement, 13swithes replacement( All wires are fished as per 2017 nec)

  13. Issued Jan 25, 2026

    410 W Wellens St

    Addition and/or Alteration · 100 amp service, replace 4-3way swithes, 4 arc fault breakers,refrigerator, computer livingroom,2 GFCI , waher & tv cable,2 redistribution basement, 6 led fixture replace ,10 receptacle replacement, 11 swithes replacement( ALL wires are fished as per 2017 )

  14. Issued Jan 22, 2026

    914 Granite St

    Addition and/or Alteration · 100 amp Distribution panel, replace 2 GFCI kitchen & bathroom, grounded service, 4 smoke detectors, one carbon /smoke basement, 4 LED light fixtures, replace 2-3 way switches, 17 receptacle replacement, 9 switches replacement.(All wires are fished as per 2017 NEC )

  15. Issued Jan 15, 2026

    2058 S Alden St

    Addition and/or Alteration · 100amps service panel,replace 2-3 way swithes, 2 GFCI replacement kitchen, 4 led fixtures replacement,11 receptacle replacement, 8 swithes replacement( All wires are fished as per 2017 Nec )

  16. Issued Jan 15, 2026

    7728 Cedarbrook Ave

    Addition and/or Alteration · Replace existing two- and three-way switches. Install a new distribution panel. Install four (4) GFCI receptacles, including two (2) in the kitchen, one (1) in the basement, and one (1) in the bathroom. Install three (3) LED light fixtures. Replace thirteen (13) receptacle outlets and fifteen (15) switches. All wiring shall be fished and installed in accordance with the 2017 NEC.

  17. Issued Jan 15, 2026

    3137 Judson St

    Addition and/or Alteration · replace 2-3way swithes, Distribution 100 panel, 4 GFCI replacemen kitcken basement.replace GFCI bathroom, 3 LED light fixtures,11 receptacle replacement, 9 swithes replacement( All wires are fished as per 2017 )

  18. Issued Jan 14, 2026

    2931 N 7th St

    Addition and/or Alteration · Replace 2 -3 way switches, install 100 amps Distribution panel, replace 5 GFCI 3 kitchen, 2bathroom, 3 receptacle living room, 5 led light fixtures, 13 receptacle replacement, 14 switches replacement( All wires are fished as per 2017 nec )

  19. Issued Nov 3, 2025

    5325 W Oxford St

    Addition and/or Alteration · replace 2-3way swithes , distribution panel, 4 GFCI kitchen & basement, 4 LED light fixtures bathroom & basement, 3 receptacle replacement, 6 swithes replacement( All wires are fished as per 2017 nec code)

  20. Issued Nov 3, 2025

    6522 Harlan St

    Addition and/or Alteration · Replace 2-3 way switches, Distribution 100amps panel, 7 GFCI 4 kitchen 2 basement & bathroom. 4 LED light fixtures 2bedroom, kitchen & 1 hallway. 7 receptacle replacement, 10 switches replacement (All wires are fished as per 2017 nec code)

  21. Issued Nov 3, 2025

    23 S 45th St

    Addition and/or Alteration · replace 2 -3way hallway ,Distribution panel,4 GFIC 2 kitchen & basement, GFCI one bathroom, one exterior fixture backyard, 5 lights 3 basement & 2 kitchen. 4 receptacle replacement, 10 switches replacement( All wires are fished as per 2017 nec code)

  22. Issued Oct 17, 2025

    2727 Sears St

    Addition and/or Alteration · replace 2-3 way swithes, 3GFCI replacement kitchen ,basement, Bath.4 LED fixtures replacement kitchen basement,4 receptacle replacement,7 swithes replacement,( All wires are fished as per 2017 nec )

  23. Issued Oct 17, 2025

    6744 Dicks Ave

    Addition and/or Alteration · INSTALL 100 AMP ELECTRICAL SERVICE AND MAIN CIRCUIT BREAKER PANEL WITH PROPER GROUNDING AND BONDING. INSTALL WIRING, RECEPACLE OUTLETS, LIGHTING AND SWITCHES, WHERE REQUIRED THROUGHOUT HOUSE. INSTALL SMOKE/CO ALARMS WITH 10 YRS BATTERY BACKUP. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC AND THE SCOPE OF WORK IN THE EXECUTED CONTRACT. **********FISHING WIRES OR USING SURFACE MOUNTED WIRE MOLD *************

  24. Issued Oct 15, 2025

    1801 W Montgomery Ave

    Addition and/or Alteration · Replace 2-3ways switches, Distribution panel,GFCI 4 kitchen, bathroom basement,washer,light fixtures backyard, one ceiling fan, 7 light fixtures, 15 replacement receptacle,17 switches replacement(All wires are fished as per 2017 nec )

  25. Issued Oct 15, 2025

    4808 Howell St

    Addition and/or Alteration · 100amp service, replace 2- 3 way switches, one Arc fault 20 amps, 4 GFCI, bathroom kitchen, washers, 4 LED lights fixtures basement, 10 replace receptacle, 10 switches replacement.( All wires are fished as per 2017 nec )

  26. Issued Oct 9, 2025

    2129 S Carlisle St

    Addition and/or Alteration · Replace 2 3-way switches,distribution panel 40 space, 2 GFCI kitchen replacement, 2 GFCI basement replacement, next to panel, placed 2 LED light fixtures basement, 12 receptacle replacement, 8 switches replacement, (All wires are fished as per 2017 nec )

  27. Issued Oct 7, 2025

    3229 Boudinot St

    Addition and/or Alteration · Replace 2-3 ways switches, one 20 amp Arc fault , distribution panel,replaced 2 gfci kitchen & bathroom,4 led light fixtures in basement,8 receptacle replacement,13 switches replacement (All wires are fished as per 2017 nec )

  28. Issued Sep 29, 2025

    342 N Gross St

    Addition and/or Alteration · RELOCATE LIGHTING OUTLET OVER SHOWER AND RECEPTACLE OUTLET IN HALLWAY. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC. FISHING WIRING ONLY

  29. Issued Sep 18, 2025

    1733 S 56th St

    Addition and/or Alteration · 100 amp service, replace 2 - 3way swithes,6 GFCI replacement, replace 2 LED light fixtures , 16 receptacle replacement, 14 swithes replacement( All wires are fished as per 2017 nec )

  30. Issued Sep 18, 2025

    5949 Windsor St

    Addition and/or Alteration · 100 amps service, replace 2 -3 ways switches, replace 2 Gfci, kitchen & bathroom 12 receptacle replacement, 13 switches replacement ( All wires wires are fished asper 2017 nec)

  31. Issued Sep 18, 2025

    5611 N Camac St

    Addition and/or Alteration · replace 4- 3 ways swithes, 1 20amp Arc fault basement,Distribution panel,7 GFCI replacement , 1 LED fixture basement, 12 receptacle replacement, 12 swithes replacement( All wires are fished as per 2017 nec )

  32. Issued Aug 1, 2025

    408 E Sharpnack St

    Addition and/or Alteration · Two 3 way switches replacement, Distribution panel, 4 GFCI replacement washer, panel, kitchen @ bathroom. New ARC fault basement, two LED light fixtures, 9 receptacles replacement, 7 switches replacement (All wires are fished as per 2017 nec )

  33. Issued Aug 1, 2025

    1912 N Lawrence St

    Addition and/or Alteration · Distribution panel, Two GFCI kitchen, two GFCI basement & bathroom, Replace 4 LED light fixtures, 10 receptacle replacement, 10 switches replacement ( All wires are fished as per 2017 nec )

  34. Issued Jul 29, 2025

    4037 Maywood St

    Addition and/or Alteration · 100 amps service, two 3-way swithes replace, 3 ARC faultt 20amp living room, 2 GFCI kitchen,4 LED light fixtures basement & hall way,9 receptacle replacement, 13 swithes replacement( All wires are fished as 2017 nec )

  35. Issued Jul 29, 2025

    1039 E Price St

    Addition and/or Alteration · Replace 2 3-way switches, 2 GFCI kitchen & bathroom, one ARC fault 20 amp basement, two ARC fault basement & first floor, 4 LED light fixtures , 12 switches replacement, 12 receptacle replacement. ( All wires are fished as per 2017 nec )

  36. Issued Jul 29, 2025

    3252 D St

    Addition and/or Alteration · 100amps service, two 3-way switch replace, one ARC fault livingroom, 4 GFCI front door, kitchen, washer & bathroom, 5 light fixture basement hall & bedroom, 8 receptacle replacement,13 switches replacement. ( All wires are fished as per 2017 nec)

  37. Issued Jul 29, 2025

    4641 G St

    Addition and/or Alteration · 100 amps Service, replace two 3-way switches, Dryer 30 amps basement, 3 GFCI kitchen, 2 GFCI washer & bathroom, 8 LED light fixtures, 12 receptacle replacement, 9 switches replacement, ( All wires are fished as per 2017 nec )

  38. Issued Jul 29, 2025

    7513 Mayland Rd

    Addition and/or Alteration · 100 amps service, replace 2-3 way switches, replace two GFCI kitchen/washer, one GFCI replace in bathroom, replace 3 led lights fixtures, replace 25 receptacle, 13 switches replacement

  39. Issued Jul 24, 2025

    1912 Rowan St

    Addition and/or Alteration · Replace 2-3 way switches..Distribution space panel, 3 GFCI replacement kitchen, 2 GFCI replacement bathrooms, replace front light & bathroom, 16 receptacle replacement, 16 switches replacement( All wires are fished as per 2017 nec )

Track this owner

We'll flag their next deal, permit, or filing — usually before the neighbors know.

Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.