Sd General Contractor
19 permits
- Records on file
- 19
Built (as contractor)
19 entries
- Issued Jun 11, 2026
Excavation · FOR SITE GRADING AND EXCAVATION WORK ASSOCIATED WITH NEW CONSTRUCTION OF A FOUR (4) STORY MULTI-FAMILY BUILDING (SEE CP-2025-004670) AS PER APPROVED PLANS. WORK TO INCLUDE TEMPORARY EXCAVATION SUPPORT SYSTEM. NO BUILDING CONSTRUCTION APPROVED ON THIS PERMIT. *2018 IBC REVIEW* **SEPARATE PERMITS REQUIRED FOR BUILDING CONSTRUCTION*
- Issued Jun 8, 2026
Excavation · FOR SITE GRADING AND EXCAVATION WORK ASSOCIATED WITH NEW CONSTRUCTION OF A FOUR (4) STORY MULTI-FAMILY BUILDING (SEE CP-2025-004669) AS PER APPROVED PLANS. WORK TO INCLUDE TEMPORARY EXCAVATION SUPPORT SYSTEM. NO BUILDING CONSTRUCTION APPROVED ON THIS PERMIT. *2018 IBC REVIEW* **SEPARATE PERMITS REQUIRED FOR BUILDING CONSTRUCTION*
- Issued May 23, 2026
New Construction · FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.
- Issued Apr 14, 2026
Addition and/or Alterations · EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Install 80K BTU 95% gas furnace, ductwork, & 10 registers (3 returns)
- Issued Apr 3, 2026
Addition and/or Alterations · FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.
- Issued Mar 3, 2026
4 units
Addition and/or Alteration · LEVEL III ALTERATIONS (NO CHANGE OF OCCUPANCY, CO TO BE ISSUED FOR PREVIOUSLY UNCERTIFIED BUILDING) FOR RENOVATIONS TO AN EXISTING FOUR (4) FAMILY DWELLING WITHIN AN EXISTING THREE (3) STORY BUILDING AS PER APPROVED PLANS. BUILDING TO BE FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**
- Issued Jan 2, 2026
1 units
New Construction · FOR THE ERECTION OF A NEW ATTACHED 2-STORY STRUCTURE WITHIN PORTIONS OF A PREVIOUSLY DEMOLISHED STRUCTURE. STRUCTURE FOR USE AS SINGLE-FAMILY HOUSEHOLD LIVING. THE BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13D. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMIITS TO BE OBTAINED FOR ALL OTHER WORK. **A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 5 FEET (1/4TH OF HEIGHT OF BUILDING)
- Issued Dec 22, 2025
1 units
Commercial Make Safe Permit · IN ACCORDANCE WITH CODE BULLETIN PM-1801, A PA PROFESSIONAL ENGINEER IS REQUIRED TO MONITOR REPAIRS MADE UNDER THIS PERMIT. THE ENGINEER MUST SUBMIT A SEALED STATEMENT TO THE DEPARTMENT CONFIRMING THAT THE STRUCTURE IS IN SOUND CONDITION AT COMPLETION. MAKE SAFE PERMIT - FOR THE DEMOLITION OF REAR CHIMNEY AND REAR DECK AS PER PLAN TO RESOLVE CASE #625924. ABUTTING SIDEWALK MUST BE CLOSED WITH FENCING A MINIMUM OF 6’ IN HEIGHT. SEPARATE STREETS DEPARTMENT PERMIT REQUIRED FOR SIDEWALK CLOSURE. A S
- Issued Nov 13, 2025
Addition and/or Alteration · For alterations to a Single Family Dwelling Property as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Structural alteration or repair is expressly PROHIBITED under this permit. Prohibited structural work includes but not limited to any modification to exterior walls, party wall, floor/roof framing and foundations, including underpinning, excavation and removal of foundation slab. ***NO WORK MAY BE PERFORMED IN
- Issued Oct 30, 2025
3 units
New Construction · FOR THE ERECTION OF AN ATTACHED 3-STORY STRUCTURE FOR USE AS MIXED-USE VACANT COMMERCIAL (SEPARATE CO REQUIRED) AND MULTI-FAMILY HOUSEHOLD LIVING THREE (3) DWELLING UNITS (R-2). THE BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13R (RESIDENTIAL) AND NFPA 13 (VACANT COMMERCIAL). ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMIITS TO BE OBTAINED FOR ALL OTHER WORK. **A COVERED WALKWAY OR SIDEWALK CLOSUR
- Issued Oct 29, 2025
Excavation · FOR EXCAVATION AND UNDERPINNING AS PER APPROVED PLANS.
- Issued Jul 18, 2025
Commercial Make Safe Permit · MAKE SAFE PERMIT TO COMPLY WITH CASE #CF-2024-037183 FOR THE REPAIR TO THE ROOF STRUCTURE OF AN EXISTING STRUCTURE AS PER ENGINEER'S REPORT AND PLAN. ABUTTING SIDEWALK MUST BE CLOSED WITH FENCING A MINIMUM OF 6' IN HEIGHT. SEPARATE STREETS DEPARTMENT PERMIT REQUIRED FOR SIDEWALK CLOSURE. A SEPARATE PERMIT IS REQUIRED FOR ANY ADDITIONAL ALTERATIONS THAT ARE NOT SPECIFICALLY ADDRESSED ON CASE #CF-2024-037183. IN ACCORDANCE WITH CODE BULLETIN PM-1801, A PA PROFESSIONAL ENGINEER IS REQUIRED TO MONI
Track this owner
We'll flag their next deal, permit, or filing — usually before the neighbors know.
Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.