Contractor

Steven Ciannavei

5 permits

Records on file
5

Built (as contractor)

5 entries

  1. Issued Jul 16, 2026

    1633 Porter St

    Addition and/or Alteration · - Residential Service Equipment not exceeding a rating of 200 amps WITH AN INCREASE IN SERVICE SIZE FROM 100 amp TO 200 amp as per Residential Service Equipment EZ Standard New lighting circuit feeds to existing devices - 1st and 2nd floor New Receptacle feeds 2nd floor bedrooms New feeds to 2nd floor HVAC closet and exterior condenser GFI receptacles where required AFCI protection where required New load center and breakers New switches, receptacles throughout home

  2. Issued Jun 29, 2026

    1183 S 13th St

    Addition and/or Alteration · AMEND 07-06-2026 New dishwasher circuit - Fishing Only Installed Dual function GFCI/AFCI breaker for dishwasher circuit Run dedicated microwave circuit - fishing only Move receptacle on right side of stove up the wall 2 feet and Add two receptacles to stove side wall tapping from existing circuit. - fishing only Move bathroom receptacle to wall by bathroom door - fishing only Move refrigerator receptacle 2 ft. to the right - fishing only

  3. Issued Feb 13, 2026

    5511 Chester Ave

    Addition and/or Alteration · Install complete fire alarm system for EXISTING mixed-use building. Automatic detection to be installed throughout nonresidential portion, all living rooms and bedrooms to have low frequency sound. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS0-2017 NEC,2016 NFPA-72.

  4. Issued Jan 1, 2026

    2643 S Beulah St

    Addition and/or Alteration · Full home rewire Service Wire will NOT be replaced New breaker panel GFI Arc fault breakers where required GFI circuits where required HVAC circuit Dedicated circuits where required

  5. Issued Aug 26, 2025

    269 S 52nd St

    Addition and/or Alteration · Replace 1st floor non functional Emergency light by front door. Add New Emergency light to basement. Run 12/2 MC cable on walls/posts from 1st floor entrance Emergency light to basement. Wiring will be strapped and fixed/secured where applicable and be protected from hazards Replacing one existing non functional emergency light and adding one new emergency light

Track this owner

We'll flag their next deal, permit, or filing — usually before the neighbors know.

Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.