Contractor

Steven Pittaoulis

16 permits

Records on file
16

Built (as contractor)

16 entries

  1. Issued Jun 3, 2026

    5306 Locust St

    Addition and/or Alteration · Furnish and install all new wiring, outlet boxes, switches, receptacles, CO and smoke detectors throughout the entire house. Replace in kind the 100 amp electrical service coming into the house, new grounding and bonding, intersystem bonding bridge, outdoor disconnect, surge protections at the end of Smoke detectors

  2. Issued May 31, 2026

    187 Widener St

    Addition and/or Alteration · Furnish and install all new wiring by means of fishing to eliminate old knob and tube circuits, replace in kind existing devices with new. Fish wiring for smoke detectors.

  3. Issued May 28, 2026

    2031 Chestnut St

    Addition and/or Alteration · Install one (1) new 100-amp subpanel for Studio Apartment 102 and reuse the existing 60-amp subpanel for Studio Apartment 101. Both subpanels shall be fed from the existing 400-amp main distribution panel located in the basement. Install new branch circuit wiring and receptacle outlets in the bathroom and kitchen areas for both studio apartments, including all required GFCI protection and code-compliant device installation. All work shall be performed in accordance with the 2017 NEC and per

  4. Issued Mar 27, 2026

    2521 South St

    Addition and/or Alteration · Furnish and install all Labor & Material for the following scope of work: Kitchen: - Reuse some existing circuits and possibly extend them to feed GFCI protected countertop receptacles, dishwasher, Garbage Disposal, 240 Volt Range, refrigerator, and (2) GFCI protected island receptacles. - New wiring for (9) recessed LED lights on 3 way dimmable, (3) pendants over the island and (1) over furnished chandelier over table, controlled by separate dimmers. - New wiring, transformer, ~10 feet of LED

  5. Issued Mar 26, 2026

    330 Oregon Ave

    Addition and/or Alteration · Connect wall sign to existing electric GP-2026-001210

  6. Issued Mar 11, 2026

    2042 Rittenhouse Sq

    Addition and/or Alteration · Provide complete wiring throughout, including lighting fixtures, switches, exit signs, emergency lighting, receptacle outlets, sprinkler tamper switch and waterflow switch connections. Install interconnected smoke and carbon monoxide alarms and a complete fire alarm system. All work to be done according to the 2017 NEC, 2016 NFPA 72 and per approved plans.

  7. Issued Feb 27, 2026

    6728 Torresdale Ave

    Addition and/or Alteration · Replace in Kind the Service: New 200-amp service, new double meter socket with outdoor breakers/disconnect, and new grounding electrode system Replace in Kind switches, receptacles, and light fixtures, Emergency exit and egress lighting, Smoke detectors, smoke/carbon detectors Remove all visible knob and tube wiring and refeed by means of fishing. Remove and replace (2) existing panels with (2) new 100 amp panels in basement Replace in kind light fixtures (supplied by property owner)

  8. Issued Feb 24, 2026

    2425 E Allegheny Ave

    Addition and/or Alteration · New cable by means of fishing to the 2nd floor for new lighting and receptacles for 2 rooms.

  9. Issued Jan 14, 2026

    2935 N Taylor St

    Addition and/or Alteration · - Remove, bore new holes, and rerun existing circuits through new joists into existing Electrical panel in basement - Secure cables

  10. Issued Jan 8, 2026

    1854 S 24th St

    Addition and/or Alteration · Install 3 800KCMIL AL SERVICE CONDUCTORS, 4 gang meter socket with service disconnects, proper grounding and bonding of Service, Subpanels in each apartment. All interior wiring with Romex concealed in walls for Receptacles, Lighting, Switches, and hardwired smoke alarms in each unit with Arc Fault breakers, 2 appliance circuits, microwave, fridge, dishwasher, garbage disposal, washer, dryer, AC, gas range, Gas Water Heater. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC Instal

  11. Issued Dec 24, 2025

    1626 S Iseminger St

    Addition and/or Alteration · Furnish and install all Labor & Material with some Demo of 2nd Floor potential knob & tube wiring, reuse some good circuits and pull new cabling for the following areas and scope: Primary Bedroom: - (6) Receptacles, (4) Recessed lights, (1) ceiling fan, (2) motion closet lights, (1) dimmer and (1) switch, (1) smoke detector Bedroom #1: - (4) Receptacles, (4) Recessed lights, (1) owner furnished ceiling fixture, (2) dimmers, (1) smoke detector Bedroom #2: - (4) Receptacles, (4) Recessed lights,

  12. Issued Nov 5, 2025

    825 Washington Ave

    Addition and/or Alteration · New 300 Amp Service, 3 gang meter socket, new 125 amp main breaker disconnect for Apartment, 60 amp main breaker panel for House, NOTE: Excluding 200 amp Commercial Space. - New wiring for Fire Alarm System throughout Apartment common area and Commercial space, and Fire Alarm Panel in Basement by House Panel, - Apartment Rewire all new per NEC 2018, with 120 Volt smokes, electric appliances (WH, Range, AC, etc), receptacles, switches, and arc fault breakers.

  13. Issued Sep 29, 2025

    336 N 60th St

    Addition and/or Alteration · Fishing of (5) new 15 amp circuits to replace knob & tube. Removal and reinstallation of existing light fixtures after new cables are fished and outlet boxes installed. Fish New MC cable and install (12) new recessed lights. Replace in kind a 200 amp main breaker panel with new Replace in kind a 100 amp subpanel with new Replace in kind a 30 amp subpanel with new

  14. Issued Sep 24, 2025

    800-02 Cathedral Rd

    Addition and/or Alteration · Tenant improvement to replace fixtures using existing circuits.  There are no new circuits being installed.  The lighting is also being replaced as it was before. *** NO FIRE ALARM ON THIS PERMIT***

  15. Issued Sep 9, 2025

    40 W Sharpnack St

    Addition and/or Alteration · New wiring per NEC 2017, less than 2000 sq ft home, with new arc fault breakers, outlet boxes, lighting, kitchen circuits, appliance circuits, laundry circuit and circuits for HVAC.

  16. Issued Aug 21, 2025

    1854 S 24th St

    Addition and/or Alteration · Install 3 800KCMIL AL SERVICE CONDUCTORS , 4 gang meter socket with service disconnects, proper grounding and bonding of Service, Subpanels in each apartment. All interior wiring with Romex concealed in walls for Receptacles, Lighting, Switches, and hardwired smoke alarms in each unit with Arc Fault breakers, 2 appliance circuits, microwave, fridge, dishwasher, garbage disposal, washer, dryer, AC, gas range, Gas Water Heater. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. **SE

Track this owner

We'll flag their next deal, permit, or filing — usually before the neighbors know.

Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.