Company / LLC

Thomas Edison Electric INC.

7 permits

Records on file
7

Built (as contractor)

7 entries

  1. Issued Mar 31, 2026

    4230 Hellerman St

    Addition and/or Alteration · We will be fishing new wire to existing switches, receptacles, smoke alarm, and lighting circuits. We will install recesses lighting throughout the home. Client will be providing the ceiling fans for installation. We will bring everything up to code. Using arc fault breakers for the new lines. Also includes a 200 amp service replacement from meter to panel w/ outdoor safety disconnect.

  2. Issued Mar 23, 2026

    5424 Whitby Ave

    Addition and/or Alteration · amend Permit 4/1/2026 - Change of Agency Existing Equipment Repair and or replacement within an existing two family dwelling.

  3. Issued Feb 5, 2026

    5209 Litchfield St

    Addition and/or Alteration · Remove / Replace Back Existing Back Stabbed Switch. Remove and re-terminate the existing 15-amp receptacle that was improperly backstabbed. Work will be performed on the existing device only—no new receptacle or wall plate is included. This service addresses the backstab issue to restore proper function. Install / Replace 15 Amp GFCI TR Duplex Receptacle at existing location. Install / Replace Client Provided Fan. Install Romex 14/2 15 Amp Circuit In Open Area Up To 20 Ft. Does not include a bre

  4. Issued Nov 18, 2025

    1019 Fillmore St

    Addition and/or Alteration · Level 2 Troubleshooting Remove cover of circuit breaker panel or fuse box to test for proper voltages, visually inspect for any safety issues, code violations, double taps or corrosion. Inspect the meter socket. The purpose is to determine if a problem exists on the utility company's equipment. Supply and Install / Replace of an Siemens 30 Space 100 Amp Main Breaker Panel Supply and Install / Replace a up to a 100 Amp Service Mast and New Meter Base Supply and Install / Replace a GFCI outlet

  5. Issued Nov 17, 2025

    4717 Conshohocken Ave

    Addition and/or Alteration · Supply and Install / Replace of an Siemens 40 Space 200 Amp Main Breaker Panel Install Romex 10/3 30 Amp Circuit In Open Area Up To 100 Ft Supply, Install or Replace a 30A Un-Fused AC / Pull Out Disconnect. Fish the line through the basement with Romex wire to the disconnect.

  6. Issued Oct 30, 2025

    364-66 Snyder Ave

    Addition and/or Alteration · Pull a 4-wire 10 AWG THHN up to 75 feet, either through existing conduit or alongside other conduits being installed. This service does not include providing a breakers or connecting the wire to other devices. Pull a 4-wire 10 AWG THHN up to 75 feet, either through existing conduit or alongside other conduits being installed. This service does not include providing a breakers or connecting the wire to other devices. Supply and Install / Replace Main Grounding System This service includes the ins

  7. Issued Oct 29, 2025

    20-40 S 33rd St

    Addition and/or Alteration · Install / Replace Siemens 20 Amp Single Pole Bolt On Breaker Install MC Wire 12/2 In Open Area Up To 75 Ft. Does not include a breaker if needed as a dedicated circuit and should be added separately.

Track this owner

We'll flag their next deal, permit, or filing — usually before the neighbors know.

Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.