Owner of record
Trustees University, Of Penna
14 permits · 3 violations
- Records on file
- 17
Permits (as owner)
14 entries
- Issued Jan 20, 2026
Addition and/or Alteration · Provide and install sixteen (16) 1x4 recessed light fixtures, nine (9) linear feet of under-cabinet lighting, four (4) downlights, four (4) exit signs, and seven (7) ceiling-mounted sensors. Install two (2) switches, eighteen (18) duplex receptacle outlets, and five (5) quad receptacle outlets. Provide backboxes and conduit pathways to the ceiling for six (6) tele/data locations and four (4) duress buttons. Install one (1) security camera and one (1) card reader. Modify the existing fire alarm s
- Issued Dec 5, 2025
Addition and/or Alteration · F&I new emergency feeder from level 1 to penthouse, F&I new ATS, panels, breakers, and VFDs. Disconnect old mechanical equipment and connect to new. Replace existing lightning in kind, modify existing fire alarm . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72.
- Issued Nov 13, 2025
Addition and/or Alterations · EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 4 Heads
- Issued Nov 11, 2025
Alterations · To install 9 fixtures, including piping from the mains, for 1 sink, 4 lavs, 2 toilets & 2 showers. Installed to the 2018 Philadelphia Plumbing Code section 919(Philadelphia Single Stack/venting System **************************ALL PIPING MUST BE METALLIC**********************************************
- Issued Oct 14, 2025
1 units
Addition and/or Alteration · FOR LEVEL II ALTERATIONS TO AN EXISTING COMMERCIAL BUILDING FOR USE AS AN APARTMENT BUILDING (B OCCUPANCY), ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
- Issued Sep 17, 2025
Addition and/or Alteration · Install one (1) light fixture, eight (8) receptacles, power for (1) EF
- Issued Sep 4, 2025
Addition and/or Alterations · FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.
- Issued Aug 6, 2025
1 units
Addition and/or Alteration · FOR A LEVEL I INTERIOR ALTERATIONS TO AN EXISTING LABORATORY SPACE (LAB #310B). BUILDING IS BE FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. **SEPARATE PERMITS REQUIRED FOR ELECTRICAL, MECHANICAL, PLUMBING & FIRE SUPPRESSION WORK**
- Issued Aug 4, 2025
1 units
Addition and/or Alteration · FOR INSTALLATION OF EQUIPMENT PLATFORM ON THE ROOF TOP AS PER APPROVED PLANS.
- Issued Jul 29, 2025
Alterations · INSTALL LAB SINK ACCORDING TO THE 2018 PPC AND PER PLANS.
- Issued Jul 23, 2025
Addition and/or Alterations · FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. 12/6/25 AMENDMENT: REMOVAL OF F/S DAMPER AND USE OF FIRE BLANKET FOR SHAFT PENETRATION OF NEW EXHAUST DUCT IN ORDER TO ADVOID A
- Issued Jul 18, 2025
Addition and/or Alteration · Install duplex receptacles qty. 16, Install GFI receptacles qty. 2, Install power for FCU qty. 2. Install power for FFU qty. 3. Install low voltage switch qty. 1. Install occupancy sensor qty. 1. Install room controller, Install type A1 qty. 4. Installation shall comply with 2017 NEC. SECO job number 6145.
- Issued Jul 16, 2025
Addition and/or Alterations · EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 4 Heads
Violations
3 entries
- Violation Jan 22, 2026OPEN
INSPECTION, TESTING AND MAINTENANCE
- Violation Jan 22, 2026OPEN
UNAPPROVED CONDITIONS
- Violation Jan 22, 2026OPEN
FDC SIGNAGE REQUIRED
Track this owner
We'll flag their next deal, permit, or filing — usually before the neighbors know.
Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.