  1. Issued Oct 26, 2026

    4101 Market St

    Addition and/or Alterations · FOR THE INSTALLATION OF 807 NEW SPRINKLER HEADS TO AN EXISTING FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING WITH AN EXISTING BACKFLOW PREVENTION ASSEMBLY PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/ HYDRAULIC CALCULATIONS.

  2. Issued Sep 23, 2026

    4101 Market St

    Addition and/or Alterations · FOR THE INSTALLATION OF 354 SPRINKLER HEADS TO AN EXISTING AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM WITH AN EXISTING BACKFLOW PREVENTION ASSEMBLY AND EXISTING FIRE PUMP IN ACCORDANCE WITH NFPA 13. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS.

  3. Issued Sep 11, 2026

    4101 Market St

    Rough-In · Rough-In Permit for FP-2026-001888 Install wet and pre-action sprinklers (354) on 8th floor

  4. Issued Aug 21, 2026

    4101 Market St

    Addition and/or Alteration · Provide labor & material to install all SSI supplied devices, modules, relays, bell, pulls & Control panel for Cybercat 50 Preaction System as per drawing and 2016 NFPA 72.

  5. Issued Jul 2, 2026

    4101 Market St

    Addition and/or Alterations · FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13 THROUGHOUT THE SEVENTH FLOOR LEVEL WITH EXISTING 6” FIRE SERVICE AND 6" BACKFLOW PREVENTION ASSEMBLY. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.

  6. Issued Jun 30, 2026

    4101 Market St

    Rough-In · Rough-In Permit for FP-2026-001314 Install (376) sprinklers on 7th floor

  7. Issued Jun 11, 2026

    4101 Market St

    Rough-In · Rough-In Permit for FP-2026-001115 Install (360) sprinklers on 6th floor, wet and pre-action. Other floors will be submitted separately.

  8. Issued Jun 11, 2026

    4101 Market St

    Addition and/or Alterations · FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13 THROUGHOUT THE SIXTH FLOOR LEVEL WITH EXISTING 6” FIRE SERVICE AND 6" BACKFLOW PREVENTION ASSEMBLY. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.

  9. Issued Apr 27, 2026

    4101 Market St

    Addition and/or Alteration · Perform tenant fit-out of a space to accommodate the installation of a fire alarm system. Work includes furnishing and installing fire alarm control equipment (as required), initiating devices, notification appliances, wiring, terminations, programming, and testing. All devices shall be properly interconnected to provide required detection and occupant notification. All work shall be performed in accordance with 2016 NFPA 72, the 2017 NEC and per approved plans.

  10. Issued Apr 16, 2026

    4101 Market St

    Alterations · ALTERATIONS TO EXISTING LAB. INTERIOR INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR LISTED FIXTURES. ALL MATERIALS SHALL BE METALLIC TO ROOF EXTENSION. VENTING TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTION 919 PHILADELPHIA SINGLE STACK VENT SYSTEM. ALL WORK TO BE INSTALLED IN STRICT COMPLIANCE WITH 2018 PPC AND APPROVED PLANS

  11. Issued Mar 17, 2026

    4101 Market St

    Addition and/or Alterations · FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.

  12. Issued Mar 16, 2026

    4101 Market St

    Addition and/or Alteration · Install panels, receptacles, poke-thru(s), lights, & lighting controls as per drawings and 2017 NEC. Fire alarm permit to be submitted separately.

  13. Issued Nov 7, 2025

    1 units

    4101 Market St

    Addition and/or Alteration · FOR LEVEL II INTERIOR ALTERATIONS FOR PARTIAL RENOVATIONS TO UNOCCUPIED BASEMENT LEVEL TO HOUSE UTILITY SPACE (S1 OCCUPANCY) AND PARTIAL FIRST FLOOR SPACE FOR BUSINESS OCCUPANCY (ACCESSORY A-3/ S-1/ S-2 OCCUPANCY) AND FOR THE FIT OUT OF UNOCCUPIED SHELL SPACE TO BE BUSINESS (B) OCCUPANCY ON THE SIXTH, SEVENTH AND EIGHTH FLOORS. ALL WORK TO BE DONE PER APPROVED PLANS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE

  14. Issued Oct 8, 2025

    4101 Market St

    Change of Use · Office - Government

Violations

3 entries

  1. Violation Mar 24, 2026OPEN

    4101 Market St

    PERIODIC TESTING

  2. Violation Mar 24, 2026OPEN

    4101 Market St

    SUPPRESSION SYSTEM TESTING & MAINTENANCE

  3. Violation Mar 24, 2026OPEN

    4101 Market St

    FDC INSPECTION, TESTING & MAINTENANCE

Track this owner

We'll flag their next deal, permit, or filing — usually before the neighbors know.

Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.