THE INDEX: 166 ▲22 · week of Oct 19 — permits firm, openings steady, deal ledger running hot

The Philadelphia Index

City File · The Public Record

File No. 1601-35-E-WALNUT-LN

1601-35 E Walnut Ln

Neighborhood
West Oak Lane
Records on file
22
First filed Sep 18, 2025Last activity Sep 22, 2026

On the record

Distress signals the city holds against this parcel — back taxes, open code violations, and unsafe designations.

Clear

No open violations or delinquencies on record for this address.

The docket

22 entries

  1. Issued Sep 22, 2026

    Permit issued — Addition and/or Alterations

    FOR THE INSTALLATION OF A NEW HVAC SYSTEMS, ASSOCIATED DUCT WORK, ROOFTOP UNITS, AND REGISTERS/DIFFUSERS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL, PLUMBING, FIRE SUPPRESSION. *IMC 2021* · contractor: Mechanical Resource Contractors, LLC

  2. Issued Sep 16, 2026

    Permit issued — New Construction

    FOR THE INSTALLATION OF A 8-INCH FIRE SERVICE LINE FOR AN AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM WITH A BACKFLOW PREVENTION ASSEMBLY AND FIRE PUMP IN ACCORDANCE WITH NFPA 13 & 20. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS. · contractor: Oliver Sprinkler Co., Inc.

  3. Issued Sep 15, 2026

    Permit issued — New Construction

    FOR INSTALLATION OF 4-INCH BACKFLOW PREVENTER AND FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH APPROVED PLANS, HYDRAULIC CALCULATIONS AND NFPA 13. · contractor: MK FIRE PROTECTION & SUPPLY, LLC

  4. Issued Sep 15, 2026

    Permit issued — Addition and/or Alteration

    Install one (1) 225-amp subpanel to supply power to the STEM lab, broadcast room, and podcast room. Provide electrical wiring for lighting fixtures, lighting controls, receptacle outlets, and telecommunications systems serving televisions, computers, data, and telephone equipment. Install branch circuits to supply power to electrical devices and HVAC equipment. All work shall be performed in accordance with the 2020 NEC and the approved plans. (No fire alarm system included in the scope of · contractor: EMMS ELECTRIC INC

  5. Issued Sep 15, 2026

    Permit issued — New Construction or Additions

    Installing new underground piping for bathrooms and mechanical room. Installing waste, vent, and water piping above ground for bathrooms and rain water · contractor: Mechanical Resource Contractors, LLC

  6. Issued Sep 15, 2026

    Permit issued — New Construction or Additions

    Installation of ductile iron domestic service to existing building as specified in plans. Installation of on site stormwater up to 5 feet from foundation wall of buildings. All work to be installed in compliance with 2021 PPC and approved plans. · contractor: JOHN J DOUGHERTY & SON INC

  7. Issued Sep 14, 2026

    Permit issued — New Construction

    FOR THE INSTALLATION OF HVAC APPLIANCES, GRDs, EXHAUSTS, AND ASSOCIATED DUCTWORK. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2021 IMC AND APPLIANCE MANUFACTURER SPECIFICATIONS. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. SEE CP-2026-004294 FOR ASSOCIATED BUILDING PERMIT. · contractor: Mechanical Resource Contractors, LLC

  8. Issued Sep 10, 2026

    Permit issued — Sitework with Onsite Utility Services

    FOR SITEWORK AS PER APPROVED PLANS. · contractor: JOHN J DOUGHERTY & SON INC

  9. Issued Sep 7, 2026

    Permit issued — Addition and/or Alteration

    FOR LEVEL II ALTERATIONS TO INCLUDE STRUCTURAL WORK, NEW PARTITIONS, DOORS, AND MILLWORK AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MEP AND FIRE SUPPRESSION WORK. *2021 IEBC* · contractor: DANIEL J. KEATING COMPANY

  10. Issued Aug 17, 2026

    Permit issued — New Construction

    Provide temporary power, permanent power/electrical distribution equipment, lighting, lighting controls, low voltage cabling/equipment, fire alarm cabling &equipment, security cameras . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS -2020 NEC ,2019 NFPA-72 - NOTED : ELECTRICAL RM DR. TO BE EQUIPPED W/ PANIC HARDWARE(110 .26(c)(3) ) , TAMPER RESISTANT RECEPTACLES REQ'D THROUGHOUT. · contractor: EMMS ELECTRIC INC

  11. Issued Aug 12, 2026

    Permit issued — New Construction

    FOR THE ERECTION OF A 1-STORY STRUCTURE WITH PRE-FAB METAL WALLS AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MEP AND FIRE SUPPRESSION WORK. FOUNDATIONS UNDER SP-2026-000585. *2021 IBC* · contractor: DANIEL J. KEATING COMPANY · 1 units

  12. Issued Jul 16, 2026

    Permit issued — Addition and/or Alteration

    Replace all existing lighting fixtures in kind throughout the recreation center. Remove existing fixtures and install new lighting fixtures of the same type and rating, including all required wiring. Remove and replace existing receptacle outlets in kind throughout the facility. All work shall be performed in accordance with the 2017 NEC and per approved plans. · contractor: Madden Electric Associates, Inc

  13. Issued Jun 29, 2026

    Permit issued — Foundation

    FOR FOUNDATIONS ONLY. *SEPARATE PERMIT REQUIRED FOR STRUCTURE* *NO EXCAVATION GREATER THAN 5FT.* · contractor: DANIEL J. KEATING COMPANY

  14. Issued Jun 8, 2026

    Permit issued — New construction, addition, GFA change

    FOR THE ERECTION OF A DETACHED ONE (1) STORY STRUCTURE; FOR USE AS AN ACTIVE RECREATION WITH EIGHT (8) ACCESSORY OFF-STREET SURFACE PARKING SPACES, TWO (2) ACCESSORY CLASS 1A BICYCLE PARKING SPACES; SIZE AND LOCATION AS SHOWN ON THE APPROVED PLAN. · contractor: Pennoni Associates, Inc.

  15. Issued Jun 5, 2026

    Permit issued — Alterations

    Plumbing installed to the 2018 Philadelphia PLUMBING code Sec 919. All piping to be metallic. • Furnish and install [6] Water Closets [6] Lavatories, [1] Uinal, [4] ELectric Water Coolers, [2] SINKS • Provide labor and material to extend from existing sanitary, vent, and domestic cold water to new fixtures as shown. · contractor: LOR-MAR MECHANICAL SERVICES LLC

  16. Issued May 18, 2026

    Permit issued — New Construction

    FOR THE ERECTION OF PRESS BOX STRUCTURE AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MEP WORK. *NO EXCAVATION GREATER THAN 5FT* · contractor: DANIEL J. KEATING COMPANY · 1 units

  17. Issued May 18, 2026

    Permit issued — New Construction

    FOR THE ERECTION OF PRESS BOX STRUCTURE AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MEP WORK. *NO EXCAVATION GREATER THAN 5FT* · contractor: DANIEL J. KEATING COMPANY · 1 units

  18. Issued May 8, 2026

    Permit issued — New Construction

    FOR THE ERECTION OF A MODULAR SHED AS PER APPROVED PLANS. · contractor: DANIEL J. KEATING COMPANY · 1 units

  19. Issued Apr 29, 2026

    Permit issued — New Construction

    FOR THE ERECTION OF A MODULAR DETACHED STRUCTURE FOR USE AS PRESS BOX (NOT FOR GENERAL PUBLIC OR SPECTATING VIEWING) AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ANY MEP WORK. *2018 IBC* · contractor: DANIEL J. KEATING COMPANY · 1 units

  20. Issued Apr 10, 2026

    Permit issued — Addition and/or Alteration

    FOR A LEVEL II INTERIOR ALTERATIONS TO A PORTION OF AN EXISTING STRUCTURE. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK.**IEBC 2018 ** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**ASBESTOS REMEDIATION REQUIRED PRIOR TO START OF WORK** AMENDMENT APPROVED 5/2/26 AMEND ALTERATIONS PERMIT CP-2025-005636 FOR CHANGES TO BUILDING LAYOUTS AS PER APPROVED PLANS. · contractor: DANIEL J. KEATING COMPANY · 1 units

  21. Issued Oct 31, 2025

    Permit issued — New construction, addition, GFA change

    FOR THE IMPROVEMENT TO THE EXISTING COMMUNITY RECREATION CENTER AND PARKS INCLUDING MULTIPLE ADDITIONAL STRUCTURES, SIZE AND LOCATION AS SHOWN ON THE PLAN · contractor: Langan Engineering and Environmental Services, Inc.

  22. Issued Sep 18, 2025

    Permit issued — New Construction or Additions

    For the erection of two detached buildings. One to be a locker room with 2 individual restrooms and the other building being a restroom building. Restroom building consists of a mens room with 2-WC, 3 urinals, 2 lavs and a Floor drain. The womens room consists of 4 WC, 2 lavs and 1 floor drain. there is also a Janitors closet consisting of a mop sink, floor drain, water heater and Backflow. Other fixtures not listed are 2 drinking fountains and 2 mop sinks. · contractor: JOHN J BEE INC

Nearby on the record

Other addresses in 19138 with recent activity on the public record.

The 19138 dashboard →The West Oak Lane dashboard →Every recent record in 19138 →

Track this parcel

We'll flag the next deed, permit, or violation on the record here — usually before the neighbors do.

Sources: Phila. Dept. of Records (deeds), L&I (permits, licenses & violations), Dept. of Revenue (tax delinquencies). Data reflects the public record as of our last weekly ingest; last activity on file September 22, 2026. Verify independently before relying on it.