THE INDEX: 64 17 · week of Jun 29permits soft, openings quiet, deal ledger quiet

The Philadelphia Index

City File · The Public Record

File No. 539-JACKSON-ST

539 Jackson St

Neighborhood
Whitman
Records on file
4
First filed Dec 19, 2025Last activity Jun 18, 2026

On the record

Distress signals the city holds against this parcel — back taxes, open code violations, and unsafe designations.

Clear

No open violations or delinquencies on record for this address.

The docket

4 entries

  1. Issued Jun 18, 2026

    Permit issued — New Construction

    FOR THE INSTALLATION OF FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING TO INCLUDE 2" MAIN FIRE SERVICE LINE WITH 2-INCH WILKINS 950XLT2 BACKFLOW PREVENTER AND AUTOMATIC FIRE SUPPRESSION SYSTEM. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. · contractor: ONEIDA FIRE PROTECTION INC

  2. Issued Feb 4, 2026

    Permit issued — Alterations

    ALTERATIONS TO EXISTING TRIPLEX. INTERIOR INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR LISTED FIXTURES. VENTING TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTION 919 PHILADELPHIA SINGLE STACK VENT SYSTEM. ALL WORK TO BE INSTALLED IN STRICT COMPLIANCE WITH 2018 PPC AND APPROVED PLANS · contractor: ZURAB ODIKADZE

  3. Issued Dec 19, 2025

    Permit issued — Addition and/or Alteration

    FOR LEVEL III ALTERATIONS TO AN EXISTING COMMERCIAL BUILDING FOR USE AS AN APARTMENT BUILDING WITH THREE (3) DWELLING UNITS (R-2 OCCUPANCY), ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. · contractor: Katzin Electrical Group LLC · 3 units

  4. Issued Dec 19, 2025

    Permit issued — Addition and/or Alteration

    Electrical Permit for combo CP-2025-003352 ELECTRIC: Install 300A service ,wiring throughout,110v interconnected smoke alarms, em/exit lighting .ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE. -NOTED: STANDARD RECEPTACLE BEHIND STACKABLE W/ GFCI BREAKER PROTECTION. · contractor: Katzin Electrical Group LLC

Nearby on the record

Other addresses in 19148 with recent activity on the public record.

The 19148 dashboard →The Whitman dashboard →Every recent record in 19148

Track this parcel

We'll flag the next deed, permit, or violation on the record here — usually before the neighbors do.

Sources: Phila. Dept. of Records (deeds), L&I (permits, licenses & violations), Dept. of Revenue (tax delinquencies). Data reflects the public record as of our last weekly ingest; last activity on file June 18, 2026. Verify independently before relying on it.