6 violations on file
- Violation Oct 2, 2024OPEN
NEW USE
- Violation Sep 25, 2024OPEN
ARCHITECT/ENGINEER SERVICES
- Violation Sep 25, 2024OPEN
ALTER EXTERIOR PORTION
- Violation Sep 25, 2024OPEN
CHANGE IN OCCUPANCY
- Violation Sep 25, 2024OPEN
OCCUPIED W/O FINAL APPROVAL
- Violation Sep 25, 2024OPEN
RETAINING WALL
The docket
6 entries
- Issued May 29, 2026
Permit issued — Addition and/or Alterations
FOR THE INSTALLATION OF AN NFPA 13R SYSTEM FOR A MULTI-FAMILY DWELLING SERVICED BY A TWO (2) INCH FIRE SERVICE LINE WITH A 2-INCH WILKINS 950 XLT2 BACKFLOW PREVENTER AND AUTOMATIC FIRE SUPPRESSION SYSTEM. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. · contractor: Reliable Fire & Mechanical, Inc.
- Issued Dec 1, 2025
Permit issued — Addition and/or Alteration
INSTALL 400 AMP ELECTRICAL SERVICE AND 4 METER PACKS WITH PROPER GROUNDING AND BONDING. INSTALL ONE 100 AMP SUBPANELS FOR HOUSE AND ONE 100 AMP SUBPANELS FOR EACH OF THE 3 DWELLING UNITS. INSTALL WIRING, LIGHTING, SWITCHES AND RECEPTACLE OUTLETS. INSTALL INTERCONNECTED SMOKE AND CO ALARMS. INSTALL FIRE ALARM SYSTEM. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC, 2016 NFPA 72 AND PER PLANS. · contractor: CALLISTO ENERGY MANAGEMENT CORPORATION
- Issued Nov 4, 2025
Permit issued — Addition and/or Alterations
FOR THE INSTALLATION OF DUCTLESS AND DUCTED HVAC APPLIANCES, GRDs, BATHROOM AND CLOTHES DRYER EXHAUSTS, DOMESTIC KITCHEN EXHAUST HOODS, AND ASSOCIATED DUCTWORK THROUGHOUT A THREE (3) FAMILY DWELLING AS PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. SEE CP-2025-001654 FOR ASSOCIATED BUILDING PERMIT. · contractor: DOTS DESIGN UP LLC
- Issued Nov 3, 2025
Permit issued — New Construction or Additions
INTERIOR ALTERATIONS AND CONSTRUCTION OF ADDITION TO CREATE A TRIPLE. INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR LISTED FXTURES. VENTING TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTION 919 PHILADELPHIA SINGLE STACK VENT SYSTEM. ALL WORK TO BE PERFORMED IN STRICT COMPLIANCE WITH 2018 PPC AND APPROVED PLANS. BASEMENT TO REMAIN VACANT AND TO BE USED AS STORAGE AND UTILITES ONLY. NO DWELLING IS TO BE PROVIDED IN BASEMENT. · contractor: SHEGDA CONSTRUCTION CORP
- Issued Sep 19, 2025
Permit issued — Addition and/or Alteration
FOR THE COMPLETE CHANGE OF OCCUPANCY AND THE ERECTION OF AN ADDITION ABOVE THE EXISITNG ATTACHED STRUCTURE. FOR USE AS MULTI-FAMILY HOUSEHOLD LIVING CONTAINING THREE (3) DWELLING UNITS. BUILDING TO BE SPRINKLERED IN ACCORDANCE WITH NFPA 13R THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. **A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN EIGHT (8) FEET OF THE BUILDING FACADE IN ACCORDANCE WITH SEC · contractor: DOTS DESIGN UP LLC · 3 units
- Issued Aug 18, 2025
Permit issued — New construction, addition, GFA change
FOR THE LEGALIZATION OF A THIRD FLOOR ADDITION AT THE REAR OF AN EXISTING ATTACHED STRUCTURE. SIZE & LOCATION AS SHOWN ON THE APPLICATION/PLANS. FOR NO CHANGE IN REAR YARD DEPTH, OCCUPIED AREA OR ROOF DECK ON THE SECOND FLOOR. · contractor: DOTS DESIGN UP LLC
Nearby on the record
Other addresses in 19135 with recent activity on the public record.
The 19135 dashboard →The Tacony dashboard →Every recent record in 19135 →
Track this parcel
We'll flag the next deed, permit, or violation on the record here — including any sheriff-sale filing — usually before the neighbors know.
Sources: Phila. Dept. of Records (deeds), L&I (permits, licenses & violations), Dept. of Revenue (tax delinquencies). Data reflects the public record as of our last weekly ingest; last activity on file May 29, 2026. Verify independently before relying on it.