Current Electrical Solutions, INC.
11 permits
- Records on file
- 11
Built (as contractor)
11 entries
- Issued Aug 25, 2026
Addition and/or Alteration · Install Cat 6 cables from the Customer's IDF on the 11th fl to renovation areas, 7 single CAT6 cable locations, 2 single CAT6 locations for WAPs, 1 dual Cat6 cable location (one date/one voice) and 1 quad CAT 6 cable location.
- Issued Aug 21, 2026
Addition and/or Alteration · Provide labor & material to install all SSI supplied devices, modules, relays, bell, pulls & Control panel for Cybercat 50 Preaction System as per drawing and 2016 NFPA 72.
- Issued Aug 12, 2026
Addition and/or Alteration · Install all SSI-supplied fire alarm devices, including modules and the control panel associated with the pre action sprinkler system. Provide all required wiring, connections, terminations. All work to be perform according to the 2020 NEC, 2019 NFPA 72 and per approved plans.
- Issued Aug 10, 2026
Addition and/or Alteration · Interior wiring for a recording studio charter school including, lighting, switches, lighting control, telecommunication wiring and receptacle outlets. All work to be perform according to the 2020 NEC and per approved plans.
- Issued Jun 1, 2026
New Construction · Provide labor & material for Control Wiring to install all SSI supplied devices, modules, relays ,key switches, bell, horn & Control panel for Preaction System as per drawing Page 1-3 & equipment counts for substation room 1785 dated 2/4/26 as per 2016 NFPA 72. All wiring to be installed using EMT conduit. Excludes line voltage to panel. Hi Reach rental fees are included.
- Issued May 12, 2026
Addition and/or Alteration · Provide 125-amp panel feeders, new electrical panel, transformer, new light fixtures, exit signs, emergency wall-packs and select demo as needed. Power wiring and disconnects for rooftop hvac units. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. AMENDMENT: Add Fire Alarm devices as per approved plans .
- Issued Mar 31, 2026
Addition and/or Alteration · Installing 11 Dual Category 6 data locations, 6 Single Category 6 locations and reuse/relocate 12 existing dual location
- Issued Jan 30, 2026
Addition and/or Alteration · Install FA plenum cable for 5 speaker strobes. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72.
- Issued Oct 13, 2025
Addition and/or Alteration · INSTALL TWO PREACTION SYSTEM FOR SUBSTATION B-10 AND B-13. INSTALL HEAT DETECTORS IN AREA AND CONNECT THE PREACTION SYSTEMS TO THE FIRE ALARM SYSTEM. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC, 2016 NFPA AND PER PLANS.
- Issued Oct 7, 2025
Addition and/or Alteration · INSTALL CLEAN AGENT SPO SYSTEM AND ONE PRE ACTION SYSTEM. CONNECT BOTH SYSTEMS TO THE FIRE ALARM SYSTEM. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC, 2016 NFPA 72 AND PER PLANS.
- Issued Jul 22, 2025
Addition and/or Alteration · Installation of 2 low-voltage pre-action systems for 2nd & 3rd floor electrical rooms as per 2016 NFPA 72. 120v Power to panels and/or equipment provided by others.
Track this owner
We'll flag their next deal, permit, or filing — usually before the neighbors know.
Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.