Entity File · The Public Record
Company / LLC
Katzin Electrical Group LLC
14 permits
- Records on file
- 14
Built (as contractor)
14 entries
- Issued Jul 2, 2026
Addition and/or Alteration · * Demo old electrical service and equipment from wall and basement * Installation of new 200 amp service and equipment * Provide 200 amp 30-circuit electrical panel and all new circuit breakers * Provide new 200 amp meter base outside at wall * Install new conduit and service conductor wiring outside on wall * Install proper size ground wire to water meter * Install (2) 8-foot ground rods driven into earth with proper grounding * Fishing (1) GFCI dedicated line to serve washer Living Room * Fish
- Issued May 13, 2026
Addition and/or Alteration · Install: - 1 vanity light - 2 hall ceiling lights - 2 bedroom ceiling lights - 1 kitchen ceiling light - 1 dining room ceiling light All work to be done according to the 2017 NEC.
- Issued Apr 13, 2026
Addition and/or Alteration · Provide temp power for construction for playground on lot using existing aerial conductor and meter on site. See note below from site permit:
- Issued Mar 18, 2026
3 units
Addition and/or Alteration · FOR LEVEL III ALTERATIONS TO AN EXISTING COMMERCIAL BUILDING FOR USE AS AN APARTMENT BUILDING WITH THREE (3) DWELLING UNITS (R-2 OCCUPANCY), ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
- Issued Jan 8, 2026
Addition and/or Alteration · Upgrade 2nd fl apt wiring: Electrical Service / Panels • Install AFCI / GFCI circuit breakers at electrical panel • Provide and install new 200 amp sub-feed breaker panel for second floor apartment • Install new 150 amp conductors from basement to second floor apartment Kitchen • Install five (5) new 120-volt, 20 amp dedicated circuits • Install one (1) 50 amp circuit and outlet for electric range Bedroom 1 • Install four (4) new 120-volt receptacles • Install one (1) switch leg with four
- Issued Dec 19, 2025
Addition and/or Alteration · Electrical Permit for combo CP-2025-003352 ELECTRIC: Install 300A service ,wiring throughout,110v interconnected smoke alarms, em/exit lighting .ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE. -NOTED: STANDARD RECEPTACLE BEHIND STACKABLE W/ GFCI BREAKER PROTECTION.
- Issued Dec 19, 2025
3 units
Addition and/or Alteration · FOR LEVEL III ALTERATIONS TO AN EXISTING COMMERCIAL BUILDING FOR USE AS AN APARTMENT BUILDING WITH THREE (3) DWELLING UNITS (R-2 OCCUPANCY), ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
- Issued Dec 19, 2025
Addition and/or Alteration · Electrical Permit for combo CP-2025-003353
- Issued Dec 19, 2025
3 units
Addition and/or Alteration · FOR LEVEL II ALTERATIONS TO AN EXISTING ATTACHED STRUCTURE. ALTERATIONS TO INCLUDE PARTIAL DEMO AND THE ERECTION OF PARTITION WALLS, REPAIR/REPLACEMENT OF STAIRS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. FOR USE AS MULTI-FAMILY (3 UNIT) HOUSEHOLD LIVING. ALL WORK TO BE DONE PER APPROVED PLANS AND DOCUMENTATION. *******************SEPARATE PERMITS FOR PLUMBING OR MECHANICAL WORK. *************************************
- Issued Nov 22, 2025
Addition and/or Alteration · -Installation of new high voltage electrical service as per plans. -Build grounding counterpoise around equipment once underground vault is set -Provide wiring & (2) 4” duct from existing utility drop pole to new underground vault (1/0 15KV conductors) -Provide (3) 4” duct from underground vault to new 400A custom MDP electrical panel (500 KCMils XHHW-2) -(48) 4” duct -(1) 1-1/2” rigid conduit from underground vault to stand-alone meter base -(1) 400A 480V custom electrical panel with all specif
- Issued Oct 2, 2025
Addition and/or Alteration · -Install new 200 amp electrical service -Install new 200 amp service conductors & 200 amp meter base @ rear of building -Provide PECO-approved corner & stand-off brackets mounted to rear wall -Provide PECO-approved (triplex) aerial conductors -Provide proper size grounding conductor to water meter
- Issued Oct 1, 2025
Addition and/or Alteration · Utilize two existing 75 KVA tranformers. Install two 100 amp 3 phase 480 volt circuits to feed two evaporator units located outside. Install two 30 amp 3 phase 208 volt circuits to power fan units inside freezer. Install 120 amp circuit to serve door heater. Install ciruit for emergency/exit lighting inside of freezer. Install fire alarm system per plans. Per NFPA 72 2016 & Philadelphia fire code 2018
- Issued Sep 12, 2025
Addition and/or Alteration · Supply and install main electrical breaker in the main switch board 277/480 volt Run 200 amp line all way to the second floor up to 200 feet long with 4 number 4/0 wire copper and one run of # 4 ground wire Supply and install 1 200 amp 480 volt 42 circuit breaker panel 225/250 amp panel one 150 amp 3 pole breaker 480 volt 20 amp 3 pole 480 volt breaker Supply and install 112.5 KVA stepdown transformer 480 volt to 120/208 Y AMENDMENT: The 112.5 KVA transformer is being installed in the adj
- Issued Jul 31, 2025
Addition and/or Alteration · INSTALL 400 AMP ELECTRICAL SERVICE AND 4 METER PACKS WITH PROPER GROUNDING AND BONDING. INSTALL ONE 60 AMP SUBPANELS FOR HOUSE, ONE 200 AMP SUBPANEL FOR COMMERCIAL SPACE AND ONE 125 AMP SUBPANEL FOR EACH OF THE 2 DWELLING UNITS. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC AND PER PLANS. ***************************FIRE ALARM SYSTEM IS NOT INCLUDED IN THE SCOPE OF WORK*************************
Track this owner
We'll flag their next deal, permit, or filing — usually before the neighbors know.
Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.