The Philadelphia Index

Entity File · The Public Record

Company / LLC

Wescott Electric Company

5 permits

Records on file
5

Built (as contractor)

5 entries

  1. Issued Apr 27, 2026

    4301-15 Wissahickon Ave

    Addition and/or Alteration · Remove, salvage, and reinstall two (2) existing light fixtures, cameras, and life safety equipment in the area between rooms. Furnish and install two (2) new electrical panels, one (1) 400-amp, 36-circuit panel and one (1) 100-amp, 24-circuit panel, including feeders and circuit breakers. Remove existing HVAC equipment feeders and conduit, and install new feeders and conduit for HVAC and MSA equipment. Furnish and install MSA gas detection system, including monitors, alarm towers, controller, a

  2. Issued Mar 6, 2026

    5208 Frankford Ave

    Addition and/or Alteration · Install new panel boards, new lighting fixtures, and distribution systems as per 2017 NEC. Install fire alarm system as per 2016 NFPA 72.

  3. Issued Oct 22, 2025

    800s Market St

    Addition and/or Alteration · Provision of all power to elevator equipment and appurtenances, elevator car and all appurtenances, receptacles, new feeders, and breakers as required. Provision of all power to equipment in elevator machine room, power to new mechanical equipment (split systems, pumps etc.), new pit receptacles and lighting, switching, new lighting to elevator machine room. Emergency telephone line , provision and wiring of new fire alarm devices, panel, and power to controller(s) for CCTV. Provision of securit

  4. Issued Aug 1, 2025

    8500 Essington Ave

    Addition and/or Alteration · Removal and replacement of twenty-six (26) rooftop air handling units (RTUs) on the roof of the B/C Baggage Claim Building as well as four (4) chilled water pumps, two (2) heat exchangers, two (2) fan coil units, two (2) hot water supply pumps, two (2) unit heaters, and two (2) glycol circulation pumps in Mechanical Room #11 serving the hydronic system for the RTUs, including associated ancillary devices, power, and controls in Mechanical Room #11; BAS for all equipment, related and required ele

  5. Issued Jul 14, 2025

    8500 Essington Ave

    Addition and/or Alteration · Remove and replace existing roof top units and associated fire alarm .ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72.

Track this owner

We'll flag their next deal, permit, or filing — usually before the neighbors know.

Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.