File No. 3151-MARKET-ST

3151 Market St

Neighborhood
University City
Records on file
17
First filed Aug 1, 2025Last activity Jun 16, 2026

On the record

Distress signals the city holds against this parcel — back taxes, open code violations, and unsafe designations.

1 violation on file

  • Violation Jun 4, 2026OPEN

    BENCHMARKING LATE

The docket

16 entries

  1. Issued Jun 16, 2026

    Permit issued — Addition and/or Alterations

    EZ KITCHEN FIRE SUPPRESSION- For the installation of New Wet Chemical Kitchen Fire Suppression System as per attached standard. Deviations from these standards require submission of construction and site plans. Install 12 gallon kitchen fire suppression system, per UL 300 · contractor: Joseph F Spaeder

  2. Issued Jun 11, 2026

    Permit issued — Addition and/or Alteration

    Install a Electronic reader and lock · contractor: TJT ELECTRICAL & PLUMBING

  3. Issued May 20, 2026

    Permit issued — Addition and/or Alterations

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. FOR THE INSTALLATION OF TWO (2) TYPE 1 HOODS (6 FT & 9.5 FT) AND ONE (1) TYPE 2 HOOD (3.5 FT)FOR A RESTAURANT WITH EXHAUST FAN AND A MAKE UP AIR FAN WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL O · contractor: HUNTER MECHANICAL INC

  4. Issued May 20, 2026

    Permit issued — Alterations

    ALTERATIONS TENANT FIT-OUT FOR RESTAURANT. INTERIOR INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR LISTED FIXTURES. ALL MATERIALS SHALL BE METALLIC TO ROOF EXTENSION. VENTING TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTION 919 PHILADELPHIA SINGLE STACK VENT SYSTEM. ALL WORK TO BE INSTALLED IN STRICT COMPLIANCE WITH 2018 PPC AND APPROVED PLANS • Furnish and install [3] Water Closet, [3] Lavatories, [1] Grease Interceptor, [1] Electric Water Heater, [9] Floor Drains, [7] Flo · contractor: LOR-MAR MECHANICAL SERVICES LLC

  5. Issued Apr 20, 2026

    Permit issued — Addition and/or Alteration

    Furnish and install fire alarm as per drawings as per 2016 NFPA 72. Furnish and install as per 2017 NEC: 20 Receptacles, 18 Quad Receptacles, 13 Data raceways, power for 2 Motorized shades, Power 1 Outside sign, Power for 1 outside menu, 1 Exterior receptacle and POS, 18' Plug mold on underside of bar, 1 Hand dryer, 3 Bathroom mirror power, 2 30amp data rack, 40 kitchen equipment, heat trace, 1 DWH-1, 4 WSHP, 1 HMUA, 4 OASF, 1 DWEF-1, 1 TEF-1, 1 KEF-1, 1 DWEF RELAY, 1 CP-1, 1 Kitchen Hood powe · contractor: SHORELINE ELECTRIC INC

  6. Issued Apr 7, 2026

    Permit issued — Addition and/or Alterations

    ***2021 IFGC REVIEW** FOR THE INSTALLATION OF A FUEL GAS PIPING SYSTEM. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. *NO MECHANICAL SYSTEMS ON THIS PERMIT* · contractor: LOR-MAR MECHANICAL SERVICES LLC

  7. Issued Apr 1, 2026

    Permit issued — Addition and/or Alterations

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (23) sprinklers · contractor: Oliver Sprinkler Co., Inc.

  8. Issued Mar 27, 2026

    Permit issued — Addition and/or Alteration

    FOR THE LEVEL II INTERIOR ALTERATIONS FOR THE TENANT FIT-OUT OF ASSEMBLY OCCUPANCY (A2) ON PARTIAL FIRST FLOOR OF AN EXISTING BUILDING. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/ FURNISHINGS AND ACCESSIBILITY IMPROVMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. · contractor: STRUCTURE TONE LLC · 1 units

  9. Issued Mar 23, 2026

    Permit issued — Change of Use

    Eating and Drinking Establishments - Sit-Down Restaurant · contractor: STRUCTURE TONE LLC

  10. Issued Oct 23, 2025

    Permit issued — Sign

    For the erection of an accessory flat wall sign on an existing structure as per approved plans.

  11. Issued Oct 22, 2025

    Permit issued — Addition and/or Alteration

    Provide new transformer and panel fed from existing electrical distribution. Provide new branch circuits for exterior signage. Only clouded areas on the drawings are part of this scope of work. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. GP-2025-005950 · contractor: ANMAR ELECTRICAL CONTRACTOR INC

  12. Issued Oct 14, 2025

    Permit issued — Signs (Accessory / Non-Accessory)

    Erection of an accessory flat wall sign on an existing structure, size and locational as shown on the plans. No window sign included. · contractor: GEORGE KENNEDY

  13. Issued Oct 2, 2025

    Permit issued — Addition and/or Alterations

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (97) SPRINKLER HEADS AS PER NFPA 13 · contractor: A & S SPRINKLER CO INC

  14. Issued Sep 4, 2025

    Permit issued — Shelter/Platform

    SHELTER PLATFORM PERMIT - Erection of a sidewalk shelter platform as per Engineered Plans. Streets Department permit is required for sidewalk closure prior to the start work. Sidewalk shed, overhead protection system at 3151 Market, to protect pedestrians while renovation work goes on overhead as per the stamped drawings.

  15. Issued Aug 14, 2025

    Permit issued — Sign

    FOR THE INSTALLATION OF TWO (2) ACCESSORY DIGITAL-DISPLAY WALL SIGNS PER APPROVED PLANS.

  16. Issued Aug 1, 2025

    Permit issued — Addition and/or Alteration

    Fire Alarm system rough in and installation to be tied into existing building fire alarm system as per 2016 NFPA 72. · contractor: CHARLES H MACDONALD ELECTRIC I

Nearby on the record

Other addresses in 19104 with recent activity on the public record.

The 19104 dashboard →The University City dashboard →Every recent record in 19104

Track this parcel

We'll flag the next deed, permit, or violation on the record here — including any sheriff-sale filing — usually before the neighbors know.

Sources: Phila. Dept. of Records (deeds), L&I (permits, licenses & violations), Dept. of Revenue (tax delinquencies). Data reflects the public record as of our last weekly ingest; last activity on file June 16, 2026. Verify independently before relying on it.