Distress signals the city holds against this parcel — back taxes, open code violations, and unsafe designations.
2 violations on file
- Violation Mar 17, 2026OPEN
EQUIPMENT ROOMS
- Violation Mar 17, 2026OPEN
OBSTRUCTIONS
The docket
16 entries
- Issued May 20, 2026
Permit issued — Addition and/or Alteration
Electrical work only: Install new conduit and wiring for branch circuits, devices, lighting, and associated wiring for elevator modernization. Replace existing circuit breaker and install new breaker, conduit, and wiring for new elevator feeder as per 2017 NEC. Upgrade existing fire alarm with new devices for elevator recall as per 2016 NFPA 72. · contractor: MARANO ELECTRIC INC
- Issued Apr 13, 2026
Permit issued — Addition and/or Alterations
FOR THE INSTALLATION OF A NEW DUCTLESS HVAC SYSTEM AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL, PLUMBING, FIRE SUPPRESSION. · contractor: HERMAN GOLDNER CO INC
- Issued Apr 13, 2026
Permit issued — Alterations
Replace sump pump. · contractor: HERMAN GOLDNER CO INC
- Issued Apr 8, 2026
Permit issued — Addition and/or Alterations
FOR AN ALTERATION TO AN EXISTING SPRINKLER SYSTEM. FOR SPRIKLER HEADS RELOCATION. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. · contractor: Oliver Sprinkler Co., Inc.
- Issued Jan 29, 2026
Permit issued — Addition and/or Alteration
Remove existing branch-circuit wiring and conduit from the circulating pump to the junction box located outside the motor control center (MCC). Install new branch-circuit wiring and conduit from the pump back to the MCC, and reconnect to the existing branch circuit and starter bucket. All work to be done according to the 2017 NEC and per approved plans. · contractor: CurrentMaster Electric, LLC.
- Issued Jan 15, 2026
Permit issued — Addition and/or Alterations
FOR A MECHANICAL SYSTEM UPGRADE TO ACCOMMODATE A PORTION OF AN EXISTING STRUCTURE. ALL WORK TO BE DONE PER APPROVED PLANS. **SEPARATE PERMIT IS REQUIRED FOR ANY PLUMBING WORK**IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. · contractor: COLLINS & COLLINS MECHANICAL
- Issued Dec 29, 2025
Permit issued — Addition and/or Alteration
Provide (10) 1x4 fixtures, 9' of undercounter light, (1) exit sign, (5) switches, (1) quad outlet, (18) duplex outlets, provide (4) backbox and pathway to ceiling for data, and backbox and pathway to ceiling for duress button as per 2017 NEC. Fire alarm modifications to include (2) speaker strobes and (2) strobes as per 2016 NFPA 72. · contractor: FRANK FISHER INC
- Issued Dec 1, 2025
Permit issued — Addition and/or Alterations
FOR THE INSTALLATION AND RELOCATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. · contractor: All Trades Distribution
- Issued Dec 1, 2025
Permit issued — Addition and/or Alterations
FOR A NEW MECHANICAL WORK. OR THE INSTALLATION OF NEW REGISTERS, AND THE REPLACEMENT OF THREE(3) EXISTING DIFFUSERS . **ALL WORK TO BE DONE PER APPROVED PLANS.** IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. **SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.** · contractor: All Trades Distribution
- Issued Dec 1, 2025
Permit issued — Addition and/or Alterations
FOR THE INSTALLATION AND RELOCATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. · contractor: All Trades Distribution
- Issued Nov 18, 2025
Permit issued — Addition and/or Alteration
FOR THE INTERIOR ALTERATIONS ASSOCIATED WITH STEAM AND DOMESTIC HOT WATER EQUIPMENT REPLACEMENT AS PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. · contractor: TARGET BLDG CONSTRUCTN INC · 1 units
- Issued Nov 7, 2025
Permit issued — Addition and/or Alteration
Furnish and install temp power to existing MEP equipment, remove the original electrical distribution, replace the original distribution with new and remove temporary feeds. Also replace in kind MEP space lighting with new LED industrial fixtures. · contractor: HATZEL & BUEHLER INC
- Issued Nov 7, 2025
Permit issued — Alterations
To replace 1 kitchen sink using existing piping. *WITHOUT PIPING* · contractor: NAGEL LAVIN INC
- Issued Oct 14, 2025
Permit issued — Addition and/or Alteration
FOR LEVEL II ALTERATIONS WITH NO CHANGE IN OCCUPANCY. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK. · contractor: FLATIRON BUILDING COMPANY · 1 units
- Issued Aug 14, 2025
Permit issued — Addition and/or Alteration
Furnish and install 9 new light fixtures, 2 AV boxes in wall and add to duplex receptacles, 1 FCU feed and 1 CU feed, 1 Occupancy Sensory Switch, using existing circuits freed up from demolition · contractor: SHORELINE ELECTRIC INC
- Issued Jul 29, 2025
Permit issued — Addition and/or Alterations
FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. · contractor: CHADWICK SERVICE COMPANY
Nearby on the record
Other addresses in 19104 with recent activity on the public record.
The 19104 dashboard →The University City dashboard →Every recent record in 19104 →
Track this parcel
We'll flag the next deed, permit, or violation on the record here — including any sheriff-sale filing — usually before the neighbors know.
Sources: Phila. Dept. of Records (deeds), L&I (permits, licenses & violations), Dept. of Revenue (tax delinquencies). Data reflects the public record as of our last weekly ingest; last activity on file May 20, 2026. Verify independently before relying on it.