Entity File · The Public Record
Contractor
Beng Ding
25 permits
- Records on file
- 25
Built (as contractor)
25 entries
- Issued Jul 3, 2026
Addition and/or Alteration · Provide electrical installation for a restaurant, including wiring for lighting fixtures, receptacle outlets, switches, emergency lighting, and connections for appliances, all from the existing electrical service. Furnish and install a fire alarm system, including control equipment (as required), initiating devices, notification appliances and wiring. All work shall be performed in accordance with the 2017 NEC, 2016 NFPA 72 and per approved plans.
- Issued Jun 4, 2026
Addition and/or Alteration · Wiring to existing 200 amp service panel with 45 lights, 53 outlets, 9 emergency lights, and 15 switches. Hookup kitchen appliance.
- Issued May 18, 2026
Addition and/or Alteration · Furnish and install a fire alarm system for a restaurant. Work includes installation of fire alarm control equipment (as required), initiating devices, notification appliances, wiring, All devices shall be properly interconnected to provide required detection and occupant notification. All work shall be performed in accordance with 2016 NFPA 72, the 2017 NEC, and per approved plans.
- Issued May 6, 2026
Addition and/or Alteration · Install fire alarm system throughout as per 2016 NFPA 72.
- Issued Apr 28, 2026
Rough-In · Rough-In Permit for EP-2026-003610 Install fire alarm system throughout.
- Issued Apr 20, 2026
Addition and/or Alteration · Wiring 18 apartments with lights, outlets, switches, smoke alarms, appliances, wiring common area lights, outlets, switches, exit signs, emergency lights, fire alarm system installation, new 800 Amp service, 20meters, 20 sub-panels, grounding, bonding, service cable running to each apartment's sub-panel, hook up fire pump, meter, and panel. All work per 2017 NEC. **The two(2) req'd Accessible spaces for ACCESSIBILITY REQUIREMENTS for fire alarm audio/visual notification appliances ,communicati
- Issued Apr 11, 2026
Rough-In · Rough-In Permit for EP-2026-003059 Install fire alarm system in the Unit B.
- Issued Mar 24, 2026
Addition and/or Alteration · Install fire alarm system to multi family dwelling. All work to be done according to the 2017 NEC, 2016 NFPA 72 and per approved plans.
- Issued Mar 10, 2026
Addition and/or Alteration · INTERIOR WIRING FOR 1ST FLOOR COMMERCIAL FIT OUT INCLUDING LIGHTS, OUTLETS, SWITCHES TO EXISTING ELECTRICAL PANEL. HOOKUP THE APPLIANCE AND EMERGENCY LIGHTS AND EXIT SIGNS.
- Issued Mar 5, 2026
Addition and/or Alteration · 200 amp service with proper grounding. Wiring two family building with lights, outlets, switches, and hookup appliances.
- Issued Mar 2, 2026
Addition and/or Alteration · 1. 100 amp service with proper grounding. 2. Rewiring throughout the single family building.
- Issued Feb 10, 2026
Addition and/or Alteration · Install fire alarm system throughout as per 2016 NFPA 72.
- Issued Dec 30, 2025
Addition and/or Alteration · Upgrade the electrical service to 200 amps. Provide an additional meter for the second-floor apartment. Ensure proper grounding and bonding All work to be done in accordance with 2017 NEC.
- Issued Dec 8, 2025
Addition and/or Alteration · Install addressable fire alarm system throughout. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72. -NOTED:HEAT DETECTOR TO BE INSTALLED IN COMMERCIAL BATHROOM.
- Issued Nov 20, 2025
Addition and/or Alteration · 200 amp service: 1. Replace 200 amp service cable. 2. Replace meter socket. 3. Grounding the service.
- Issued Oct 29, 2025
Addition and/or Alteration · INSTALL BRANCH CIRCUITS TO KITCHEN AND DINING ROOM. INSTALL LIGHTING, SWITCHES AND RECEPTACLE OUTLETS TO KITCHEN AND DINING ROOM. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC.
- Issued Oct 23, 2025
Addition and/or Alteration · INSTALL 400 AMP ELECTRICAL SERVICE AND 5 METER PACKS WITH PROPER GROUNDING AND BONDING. INSTALL ONE 60 AMP SUBPANELS FOR HOUSE, ONE 125 AMP SUBPANEL FOR ONE DWELLING UNIT AND ONE 150 AMP SUBPANEL FOR EACH OF THE 3 DWELLING UNITS. INSTALL WIRING, LIGHTING, SWITCHES AND RECEPTACLE OUTLETS. INSTALL INTERCONNECTED SMOKE AND CO ALARMS. INSTALL FIRE ALARM SYSTEM. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC, 2016 NFPA 72 AND PER PLANS
- Issued Oct 20, 2025
Addition and/or Alteration · INSTALL 400 AMP ELECTRICAL SERVICE AND 4 METER PACKS WITH PROPER GROUNDING AND BONDING 1/0 COLD WATER GROUND. INSTALL ONE 100 AMP SUBPANELS FOR HOUSE, ONE 200 AMP SUBPANEL FOR THE COMMERCIAL SPACE AND TWO 125 AMP SUBPANEL FOR EACH OF THE 2 DWELLING UNITS. INSTALL WIRING, LIGHTING, SWITCHES EMERGENCY LIGHTING AND RECEPTACLE OUTLETS. INSTALL INTERCONNECTED SMOKE AND CO ALARMS. INSTALL FIRE ALARM SYSTEM. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC, 2016 NFPA 72 AND PER PLANS. Amendment
- Issued Oct 15, 2025
Addition and/or Alteration · INSTALL 400 AMP ELECTRICAL SERVICE AND 4 METER PACKS WITH PROPER GROUNDING AND BONDING. INSTALL ONE 100 AMP SUBPANELS FOR HOUSE, ONE 200 AMP SUBPANEL FOR THE COMMERCIAL SPACE AND TWO 125 AMP SUBPANEL FOR EACH OF THE 2 DWELLING UNITS. INSTALL WIRING, LIGHTING, SWITCHES EMERGENCY LIGHTING AND RECEPTACLE OUTLETS. INSTALL INTERCONNECTED SMOKE AND CO ALARMS. INSTALL FIRE ALARM SYSTEM. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC, 2016 NFPA 72, AND PER PLANS.
- Issued Sep 24, 2025
Addition and/or Alteration · Install EV charging station inside the garage.
- Issued Sep 17, 2025
Addition and/or Alteration · Rewiring the whole house to existing 200 amp service.
- Issued Sep 12, 2025
Addition and/or Alteration · Install fire alarm system throughout. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72. GM-2025-008141
- Issued Aug 19, 2025
Addition and/or Alteration · Install fire alarm system as per 2016 NFPA 72.
- Issued Jul 14, 2025
Addition and/or Alteration · Install 600 Amp Service with 6 meters and disconnects with grounding. Wire 4 apartments with switches, lights, outlets, smoke alarms and power to equipment as per 2017 NEC.
- Issued Jul 14, 2025
Rough-In · Rough-In Permit for EP-2025-006692 Install fire alarm system.
Track this owner
We'll flag their next deal, permit, or filing — usually before the neighbors know.
Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.