Entity File · The Public Record
Company / LLC
Madden Electric Associates, INC
29 permits
- Records on file
- 29
Built (as contractor)
29 entries
- Issued Jul 9, 2026
Addition and/or Alteration · Minor renovations to add receptacles in wire mold on outside wall. All work to be done according to the 2017 NEC and per approved plans.
- Issued Jun 29, 2026
Addition and/or Alteration · Electrical Fit out on 12th floor for truist bank offices. New Lighting New Power 1-Sub Panel. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. AMENDMENT: Install fire alarm per approved drawings.
- Issued Jun 11, 2026
Addition and/or Alteration · RELOCATING RECEPTACLES, LIGHTS, POWER FOR CONDENSORS, SITE LIGHTING, AND NEW CONDENSORS AS PER 2017 NEC.
- Issued Jun 1, 2026
Addition and/or Alteration · Electrical Permit for combo CP-2026-001082: Interior wiring and telecommunications fit out for tenant space, Dunkin, all work per approved plans. NEC 2017 ***NO FIRE ALARM ON THIS PERMIT.***
- Issued May 28, 2026
Addition and/or Alteration · Install two (2) 200-amp subpanels from the existing electrical service, including all required feeders, overcurrent protection, grounding, bonding, and terminations. Provide complete electrical distribution, including installation of wiring, lighting fixtures, switches, and receptacle outlets. Install branch circuits to furnish power for appliances and equipment. Install smoke and carbon monoxide alarms as required. All work shall be performed in accordance with the 2017 NEC and per appro
- Issued May 26, 2026
Addition and/or Alteration · Perform electrical upgrades in the lobby and office spaces on the first floor, including installation and/or replacement of wiring, lighting fixtures, lighting control systems, exit signs, emergency lighting, and receptacle outlets. Work includes all associated branch circuits, devices, grounding, and connections required to support the upgraded systems. Install fire alarm system. All work shall be performed in accordance with the 2017 NEC, 2016 NFPA 72 and per approved plans.
- Issued May 21, 2026
New Construction · NEW 4000 AMP BUILDING SERVICE, FROM PAD MOUNTED TRANSFORMER, NEW LIGHTING, FIRE PUMP, AND POWER AS PER 2017 NEC. INSTALL FIRE ALARM PER DRAWINGS AS PER 2016 NFPA 72. NO GENERATOR AND NO TELE/DATA.
- Issued May 18, 2026
New Construction · INSTALL 1200 AMP SERVICE WITH GROUNDING. INSTALL LIGHTING, RECEPTACLES, SMOKE/CO ALARMS, FIRE PUMP WIRING, TELECOMMUNICATIONS WIRING, AND PROVIDE POWER TO EQUIPMENT AS PER 2017 NEC. INSTALL FIRE ALARM AS PER 2016 NFPA 72.
- Issued Apr 29, 2026
Addition and/or Alteration · Apartment Building- Install New HT Service, New Fire Alarm, New Low Voltage telecommunications. New outside generator. New Panels and gear throughout the building, all new lighting and receptacles. Install two-way communication Per 110.26. C.3c room C05 to have panic listed hardware All work per approved plans NEC 2017
- Issued Apr 2, 2026
Addition and/or Alteration · Install New Lighting, New pathways only for low voltage, Fire Alarm , Receptacles .ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72.
- Issued Apr 1, 2026
Addition and/or Alteration · Electrical Permit for combo CP-2026-001187
- Issued Mar 24, 2026
Addition and/or Alteration · Strip Mall Restaurant - MC Cable throughout space. Install lighting, receptacles, tele/data, outlets and all electrical devices per plans and 2017 NEC.
- Issued Mar 9, 2026
Addition and/or Alteration · Electrical Permit for combo CP-2025-004495
- Issued Feb 11, 2026
New Construction · 200 Amp Temporary Service for construction site. All work to be done according to the 2017 NEC.
- Issued Feb 2, 2026
Addition and/or Alteration · Provide Temporary power for construction site renovation of apartment tower. Manhoist power and temporary lighting power for construction
- Issued Jan 28, 2026
Addition and/or Alteration · ELECTRICAL WORK FOR NEW COUNTERTOPS AND NEW CEILINGS INCLUDING LIGHTS, AND RECEPTACLES, NO FIRE ALARM. EXISTING PANEL TO BE USED
- Issued Jan 8, 2026
Addition and/or Alteration · Install receptacles lighting with a 2 room renovation & 1 Panel upgrade .ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. **NO FIRE ALARM ON THIS PERMIT**
- Issued Dec 23, 2025
Addition and/or Alteration · Electrical Permit for combo CP-2025-005267 amendment: Install New fire alarm for fitout to existing system in building.
- Issued Dec 11, 2025
Addition and/or Alteration · Installing new 2 x 2 light fixtures and recessed lighting as per 2017 NEC. Tie into existing branch circuits and switches.
- Issued Dec 2, 2025
Addition and/or Alteration · PROVIDE CONDUIT AND WIRING FOR 2 20AMP CIRCUITS TO FEED ROOFTOP LED SIGN. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC AND PER PLANS.
- Issued Dec 2, 2025
Addition and/or Alteration · Provide 120V circuit to entrance way blade sign only. 100' of conduit and wire for entrance way blade sign. Permit is for sign only. Make connection to panel with 20A breaker
- Issued Oct 22, 2025
Addition and/or Alteration · MINOR ELECTRICAL DEMO. INSTALLING RECEPTACLES, LIGHTING, LIGHTING CONTROLS, STANDALONE NURSE CALL, SOUND MASKING, PATHWAYS ONLY FOR LOW VOLTAGE AS PER 2017 NEC. AMENDMENT: Install fire alarm system as per 2016 NFPA 72.
- Issued Oct 17, 2025
Addition and/or Alteration · Area is under 2,000 sqFt, no electrical review required. Alterations to existing lobby Relocate reception desk Provide power in desk Re work some existing lighting ***NO FIRE ALARM ON THIS PERMIT***
- Issued Aug 4, 2025
Addition and/or Alteration · Interior renovations using existing panels, panel, and service. New Lights and RECEPTACLES (HOSPITAL GRADE WHERE SPECIFIED) WIRING IN SPECIFIED PATIENT CARE SPACES TO COMPLY W/ 517.13(A) . ALL WORK WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS and 2017 NEC. Install fire alarm system as per 2016 NFPA-72 and 2018 PHILA FIRE CODE.
- Issued Aug 4, 2025
501 N Christopher Columbus Blvd
Addition and/or Alteration · INSTALL WIRING TO FEED POWER TO ILLUMINATED SIGNS. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC AND PER PLANS.
- Issued Jul 28, 2025
Addition and/or Alteration · Interior renovations utilizing existing electrical panels. New lights ,receptacles & wiring in patient care areas (hospital grade), tamper resistant receptacles in waiting rm area. and new fire alarm throughout. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72.
- Issued Jul 17, 2025
Addition and/or Alteration · Interior renovations utilizing existing electrical panels. New lights ,receptacles & wiring in patient care areas (hospital grade), tamper resistant receptacles in waiting rm area. and new fire alarm throughout. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72.
- Issued Jul 15, 2025
Addition and/or Alteration · Interior renovations using existing panels and service. New Lights and RECEPTACLES (HOSPITAL GRADE WHERE SPECIFIED) WIRING IN SPECIFIED PATIENT CARE SPACES TO COMPLY W/ 517.13(A) . ALL WORK WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS and 2017 NEC. Install fire alarm system as per 2016 NFPA-72 and 2018 PHILA FIRE CODE.
Track this owner
We'll flag their next deal, permit, or filing — usually before the neighbors know.
Entities are grouped by a normalized name from the public record; a separate legal entity per building is common, so some portfolios span several related names. Sources: Phila. Dept. of Records (deeds), L&I (permits & violations), Dept. of Revenue (tax delinquencies), reflecting the record as of our last weekly ingest. Verify independently before relying on it.
Last generated August 1, 2026.