| Issued | Address | Type / scope | Units | Contractor | Com. | Zip |
|---|---|---|---|---|---|---|
| Issued Jun 13, 2026 | 30-36 S 15TH ST | Addition and/or AlterationInstall and wire 15 linear lights, 16 2X4 lighting fixtures, occupancy sensors, emergency lights, occupancy sensors, and switches. Run power and install receptacles, 5 floor boxes. Run power and hook up work stations. Demo old 15 kVa transformer and install new 45 kVa transformer. Demo 16B panel, install new 150 amp main breaker panel and wire circuits from 16B to new panel. Run 28 Cat6 drops, install junction boxes, jacks, covers, and patch panel and plywood. Install speaker str | — | ALPHA TECHNOLOGY ENTERPRISE LLC | C |
Free tool
Want every new-construction permit mapped to corridors, weekly? Get the free Building Report →
| 19102 |
| Issued Jun 13, 2026 | 711-19 N 7TH ST | New ConstructionFOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. | — | AAK BUILDING CONSTRUCTION GROUP LLC | C | 19123 |
| Issued Jun 13, 2026 | 6337 WOODBINE AVE | AlterationsExterior main drain replacement. | — | MARKO TRAVAS | 19151 |
| Issued Jun 13, 2026 | 2013 MEMPHIS ST | AlterationsMain drain repair. | — | MARKO TRAVAS | 19125 |
| Issued Jun 13, 2026 | 3609 ESSEX LN | Alterationsinstall new fixtures in bathrooms, and kitchen install new water heater and expansion tank | — | ROBERT KATILAS | 19114 |
| Issued Jun 13, 2026 | 1902 CECIL B MOORE AVE | AlterationsCurb trap, fresh air inlet & main drain. | — | MARKO TRAVAS | 19121 |
| Issued Jun 13, 2026 | 2632 S CHADWICK ST | AlterationsCurb trap, fresh air inlet & main drain. | — | MARKO TRAVAS | 19145 |
| Issued Jun 13, 2026 | 332 LOMBARD ST | Addition and/or AlterationsFOR A MECHANICAL WORK TO ACCOMMODATE THE 2ND FLOOR LEVEL OF AN EXISTING STRUCTURE. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. | — | J CONSTRUCTION INC | C | 19147 |
| Issued Jun 13, 2026 | 711-19 N 7TH ST | New ConstructionFOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. | — | AAK BUILDING CONSTRUCTION GROUP LLC | C | 19123 |
| Issued Jun 13, 2026 | 711-19 N 7TH ST | New ConstructionFOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. | — | AAK BUILDING CONSTRUCTION GROUP LLC | C | 19123 |
| Issued Jun 13, 2026 | 161 CARPENTER LN | New ConstructionMechanical / Fuel Gas Permit for combo RP-2025-013308 | — | Airzonehvac inc | 19119 |
| Issued Jun 12, 2026 | 1143 HELLERMAN ST | AlterationsSewer service spot repair. | — | Hartmann and Sons Water and Sewer PA, Inc | 19111 |
| Issued Jun 12, 2026 | 1545 S RINGGOLD ST | New ConstructionFOR NEW CONSTRUCTION OF A TWO-STORY ATTACHED BUILDING WITH CELLAR FOR USE AS SINGLE-FAMILY HOUSEHOLD LIVING. BUILDING TO BE FULLY SPRINKLERED WITH NFPA 13D. SEPARATE PERMITS REQUIRED FOR EXCAVATION, MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION. | 1 | FINE PRINT CONSTRUCTION LLC | 19146 |
| Issued Jun 12, 2026 | 1631 N PHILIP ST | AlterationsHT and FAI replacement | — | JOSE RODRIGUEZ | 19122 |
| Issued Jun 12, 2026 | 1519 S LECOUNT ST | New ConstructionFOR NEW CONSTRUCTION OF A TWO-STORY ATTACHED BUILDING WITH CELLAR FOR USE AS SINGLE-FAMILY HOUSEHOLD LIVING. BUILDING TO BE FULLY SPRINKLERED WITH NFPA 13D. SEPARATE PERMITS REQUIRED FOR EXCAVATION, MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION. | 1 | FINE PRINT CONSTRUCTION LLC | 19146 |
| Issued Jun 12, 2026 | 5344 GRAYS AVE | Addition and/or AlterationRewire as per Nec 2017 Smokes and Co detector 20 recess lights Install arch faults as per nec 2017 Replace 100amp panel inkind. | — | OMAR RIVERA | 19143 |
| Issued Jun 12, 2026 | 300 E UPSAL ST | Addition and/or AlterationFOR A FACADE IMPROVEMENT PER APPROVED PLANS. **MECHANICAL WORK TO BE LIMITED TO INSTALLATION OF NEW DUCTLESS HVAC SYSTEM ** | 2 | ANTHONY A DENNIS JR | C | 19119 |
| Issued Jun 12, 2026 | 1735 MARKET ST | Addition and/or AlterationProvide and install 388 Cat6 plenum cables at 150' average. Provide and install 12 Cat6A plenum cables at 150' average. All work will be completed per current NEC. No rescue systems work. | — | LANCONNECT INC | C | 19103 |
| Issued Jun 12, 2026 | 2411 N 11TH ST | New Construction or AdditionsAMEND PERMIT 6/16/2026 - 1-backflow,3-lav sinks,3-water closets,2-tubs,1-floor drain,1-laundry sink,1-water heater,1-hose bib,1-kitchen sink Plumbing Permit (Interior) for combo RP-2024-006397 | — | JOSEPH ROSATI INC | 19133 |
| Issued Jun 12, 2026 | 225 N 38TH ST | Addition and/or AlterationInstallation of new lighting, as per drawings. Installation of power to receptacles, HVAC equipment, as per drawings Installation of new 400A electrical service as per drawings Installation of low voltage, CAT, security cable, tele/data cable, as per APPROVED drawings-2017 NEC. | — | FOX CHASE ELECTRICAL INC | C | — |
| Issued Jun 12, 2026 | 1608 W JUNIATA ST | Make Safe Permit For RPMAKE SAFE PERMIT TO COMPLY WITH UNSAFE VIOLATION 670888 TO INCLUDE REPLACEMENT OF FRONT EXTERIOR WALL PER APPROVED PLANS, ENGINEER’S REPORT AND IN ACCORDANCE WITH CODE BULLETIN PM-1801. LICENSED PA PROFESSIONAL ENGINEER IS REQUIRED TO MONITOR REPAIRS MADE UNDER THIS PERMIT. THE ENGINEER MUST SUBMIT A SEALED STATEMENT TO THE DEPARTMENT CONFIRMING THAT THE STRUCTURE IS IN SOUND CONDITION AT COMPLETION. | — | PROPERTY TWINS RENOVATION LLC | 19140 |
| Issued Jun 12, 2026 | 4056 PARKSIDE AVE | AlterationsREPAIR/REPLACE 3/4" WATER SERVICE CURB TO HOUSE. | — | BUZZ-DUZZ PLUMBING HEATING & AC | 19104 |
| Issued Jun 12, 2026 | 303 FOUNTAIN ST | New Construction or AdditionsWater distribution installation for townhome. | — | Right Price Plumbing & Heating LLC | 19128 |
| Issued Jun 12, 2026 | 5400R LANGDON ST | Change of UseWholesale, Distribution, and Storage - Warehouse.; Research and Development | — | Klehr Harrison Harvey Branzburg LLP | C | 19124 |
| Issued Jun 12, 2026 | 2233 CECIL B MOORE AVE | Addition and/or AlterationINTERIOR ALTERATION TO THE FIRST FLOOR OF AN EXISTING STRUCTURE, ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. | — | TEROX ELECTRIC & CONST. CORP | C | 19121 |