Reading the ledger…
THE INDEX: 64 ▼17 · week of Jun 29 — permits soft, openings quiet, deal ledger quiet
Reading the ledger…
The raw feed behind the newsletter. Free tier: the trailing 90 days, 25 rows a page — enforced at the query, not just the pixels.
Reading the record?Get the week's biggest deals, permits, and the LLCs behind them — one free email every Thursday, every number checkable here.
Index Pro — full history, CSV exports, and morning-of alerts. $39/mo, coming soon. Get notified at launch:
New · The distress rolls
39,333 properties owe the city back taxes — 1,734 flagged for sheriff sale.
| Issued | Address | Type / scope | Units | Contractor | Com. | Zip |
|---|---|---|---|---|---|---|
| Issued Jul 6, 2026 | 3844 ASPEN ST | New construction, addition, GFA changeNew construction of a single-family structure as per approved plan NTE 38' in height. Affordable housing Turn Key program. | — | CANNO DESIGN LLC | 19104 | |
| Issued Jul 6, 2026 | 1840 S CAMAC ST | New ConstructionMechanical / Fuel Gas Permit for combo RP-2025-012102 |
Free tool
Want every new-construction permit mapped to corridors, weekly? Get the free Building Report →
| — |
| Sanks Mechanical |
| 19148 |
| Issued Jul 6, 2026 | 2255 N 22ND ST | New Construction or AdditionsNEW CONSTRUCTION OF 16 UNIT 4 STORY APARTMENT BUILDING. INTERIOR INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR LISTED FIXTURES. VENTING TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTION 919 PHILADELPHIA SINGLE STACK VENT SYSTEM. ALL WORK TO BE INSTALLED IN STRICT COMPLIANCE WITH 2018 PPC AND APPROVED PLANS | — | THOMAS UHL | C | 19132 |
| Issued Jul 6, 2026 | 1623 WEBSTER ST | New construction, addition, GFA changeFOR THE ERECTION OF AN ATTACHED THREE (3) STORY STRUCTURE WITH ROOF DECK ACCESSED BY A ROOF DECK ACCESS STRUCTURE; FOR USE AS A SINGLE-FAMILY HOUSEHOLD LIVING; SIZE AND LOCATION AS SHOWN ON THE PLAN. | — | TOMMY TRAN | 19146 |
| Issued Jul 6, 2026 | 1600 E BERKS ST | New ConstructionFOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITN NFPA 13D, WITH A ONE-INCH COMBINED FIRE SERVICE LINE, AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. | — | Aqueduct Fire Protection Systems, LLC | 19125 |
| Issued Jul 6, 2026 | 1447 N ORKNEY ST | New Construction or AdditionsPlumbing Permit (Water Distribution) for combo RP-2025-012890 | — | FERKO PLUMBING & HEATING CO INC | 19122 |
| Issued Jul 6, 2026 | 5742 N LAMBERT ST | Make Safe Permit For RPFOR THE REPLACEMENT OF THE DAMAGED PORCH FRAMING MEMBERS AND WALLS TO RESOLVE CF-2025-132437. ALL WORK TO BE DONE PER APPROVED PLANS AND ENGINEERING INSPECTION LETTER. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. A SEPARATE PERMIT IS REQUIRED FOR ANY ADDITIONAL ALTERATIONS THAT ARE NOT SPECIFICALLY ADDRESSED ON CF-2025-132437. "IN ACCORDANCE WITH CODE BULLETIN PM-1801, A PA PROFESSIONAL ENGINEER IS REQUIRED TO MONITOR REPAIRS MADE UNDER THIS PERMIT. THE ENGINE | — | The Working Crew, LLC | 19138 |
| Issued Jul 6, 2026 | 3842 ASPEN ST | New construction, addition, GFA changeNew construction of a single-family structure as per approved plan NTE 38' in height. Affordable housing Turn Key program. | — | CANNO DESIGN LLC | 19104 |
| Issued Jul 6, 2026 | 745 E ONTARIO ST | AlterationsREPLACE CURB TRAP, FRESH AIR INLET, HOUSE DRAIN, 3/4" WATER LINE, MAIN DRAIN IN BASEMENT AND RAIN WATER CONDUCTOR . | — | MR D'S PLUMBING & HEATING | 19134 |
| Issued Jul 6, 2026 | 1412 FRANKFORD AVE | AlterationsALTERATIONS TO EXISTING RESTAURANT. . INTERIOR INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR LISTED FIXTURES. ALL MATERIALS SHALL BE METALLIC TO ROOF EXTENSION. VENTING TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTION 919 PHILADELPHIA SINGLE STACK VENT SYSTEM. ALL WORK TO BE INSTALLED IN STRICT COMPLIANCE WITH 2018 PPC AND APPROVED PLANS | — | NHAN T LE | C | 19125 |
| Issued Jul 6, 2026 | 3240-64 N HANCOCK ST | Addition and/or AlterationsEZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Replace 12 flexible ducting runs and associated diffusers. In kind replacements with new diffusers. Duct was found to be damaged, and diffusers were rusted. Flexible duct runs do not exceed 6' and ductwork is R6 insulated. All work will be self-containe | — | FREEDOM ENERGY PARTNERS | C | 19140 |
| Issued Jul 6, 2026 | 3400 SPRUCE ST | Addition and/or AlterationsEZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (2) sprinklers to accommodate interior alterations to 5th floor | — | Oliver Sprinkler Co., Inc. | C | 19104 |
| Issued Jul 6, 2026 | 623-25 PINE ST | Addition and/or AlterationFOR A LEVEL I INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY ) TO AN EXISTING STRUCTURE. FOR RESTROOM UPDATES ON THE FIRST AND SECOND FLOOR LEVEL OF AN EXISTING STRUCTURE. STRUTURAL WORK TO BE INCLUDED. ALL WORK TO BE DONE PER APPROVED PLANS.** IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK**IEBC 2018**EXISTING BUILDING IS NOT SPRINKLERED** SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK** | 1 | PINEMAR, INC | C | 19106 |
| Issued Jul 6, 2026 | 145 MANHEIM ST | Addition and/or AlterationInstall a new fire alarm system to NFPA 72 2016 and 2017 NEC Code. ***ALL WORK PER APPROVED PLANS*** | — | HARRY BECK | C | 19144 |
| Issued Jul 6, 2026 | 4709 SPRINGFIELD AVE | Addition and/or AlterationKitchen electrical rewiring in residential triplex unit 3: installing new circuits from panel to kitchen via surface mounted wire mold conduit. Adding dedicated 20-amp circuits for countertop appliances, dishwasher, refrigerator, and stove. Installing AFCI/GFCI receptacles per NEC code. No walls opened- all surface mount exterior conduit. | — | GLEN FORD | C | 19143 |
| Issued Jul 6, 2026 | 356 E GORGAS LN | EZ Bathroom & Kitchen RemodelReplace supply and waste lines of existing plumbing fixtures Replace toilet, sink and shower No basement work No structural changes | — | JACK EDMONDSON, INC. | 19119 |
| Issued Jul 6, 2026 | 2123 FERNON ST | New ConstructionFOR THE ERECTION OF AN ATTACHED TWO (2) STORY STRUCTURE. FOR USE AS A SINGLE FAMILY HOUSEHOLD LIVING. BUILDING TO BE SPRINKLERED IN ACCORDANCE WITH NFPA 13D THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. **A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN EIGHT (8) FEET OF THE BUILDING FACADE IN ACCORDANCE WITH SECTION 3306 OF THE 2018 IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMIT REQUIRE | 1 | SPRUCE BUILDERS LLC | 19145 |
| Issued Jul 6, 2026 | 1400 S NAPA ST | New ConstructionINSTALL 200 AMP, WIRING THROUGHOUT, INSTALL LIGHT FIXTURES, OUTLETS, SWITCHES, SMOKE DETECTOR, GROUNDING SYSTEM. | — | EAGLE ELECTRICAL CONSTRUCTION CO INC | 19146 |
| Issued Jul 6, 2026 | 1932 S NORWOOD ST | New ConstructionFOR THE ERECTION OF AN ATTACHED TWO (2) STORY STRUCTURE. FOR USE AS A SINGLE FAMILY HOUSEHOLD LIVING. BUILDING TO BE SPRINKLERED IN ACCORDANCE WITH NFPA 13D THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. **A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN EIGHT (8) FEET OF THE BUILDING FACADE IN ACCORDANCE WITH SECTION 3306 OF THE 2018 IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMIT REQUIRE | 1 | SPRUCE BUILDERS LLC | 19145 |
| Issued Jul 6, 2026 | 147-53 BERKLEY ST | Addition and/or AlterationFOR THE INSTALLATION OF STEEL SHORING AS PER APPROVED PLANS. | — | Philly Office Retail LLC | C | 19144 |
| Issued Jul 6, 2026 | 1901 TYSON AVE | Addition and/or Alteration Connect 2 hydration stations to electricity (replace in kind). | — | Rafter Electric, Inc | C | 19149 |
| Issued Jul 6, 2026 | 3158 N BAMBREY ST | Addition and/or AlterationProvide light, branch circuit and installation Provide receptacle, branch circ. & installation Provide electric heater connection & branch | — | DAVIS S OWENS GROUP | 19132 |
| Issued Jul 6, 2026 | 2281 OREGON AVE | Addition and/or AlterationsEZ KITCHEN FIRE SUPPRESSION- For the installation of New Wet Chemical Kitchen Fire Suppression System as per attached standard. Deviations from these standards require submission of construction and site plans. Installation of an Amerex KP kitchen fire suppression systems, per UL 300 | — | ATLANTIC FIRE EQUIPMENT CO INC | C | 19145 |
| Issued Jul 6, 2026 | 4222 MANAYUNK AVE | Addition and/or AlterationUpgrade to 400 amp electrical service with 3 meter socket and proper grounding and bonding. All work to be done according to the 2017 NEC and per approved plans. | — | PHILLY TELECOM | C | 19128 |
| Issued Jul 6, 2026 | 2934 N BONSALL ST | Addition and/or AlterationFOR REMOVAL AND REPLACEMENT IN KIND OF THE FRONT AND REAR EXTERIOR WALLS AND FOR INTERIOR ALTERATIONS TO AN EXISTING SINGLE-FAMILY STRUCTURE AS PER APPROVED PLAN. *SEPARATE PERMITS REQUIRED FOR ELECTRICAL, PLUMBING, AND MECHANICAL WORK* | — | ANM INVESTMENT INC | 19132 |